Scanning electrochemical microscopy for study of aptamer-thrombin interfacial interactions on gold disk microelectrodes

被引:4
作者
Bai, Huei-Yu [1 ]
Javier del Campo, F. [2 ]
Tsai, Yu-Chen [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem Engn, Taichung 402, Taiwan
[2] Univ Autonoma Barcelona, Centro Nacl Microelect CNM IMB, Bellaterra 08193, Spain
关键词
Scanning electrochemical microscope; Microelectrode; Thrombin; Aptamer; ELECTRODE ARRAYS; NANOPARTICLES; SPECTROSCOPY; VOLTAMMETRY; APTASENSOR; BIOSENSOR;
D O I
10.1016/j.jcis.2013.11.050
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A feasibility for the determination of thrombin on gold disk microelectrodes (GDMs) using scanning electrochemical microscopy (SECM) is reported. The assembly process step-by-step of thrombin aptasensor on GDMs is monitored by SECM. SECM analysis reveals the immobilization of thrombin aptamers on GDMs. The interaction between thrombin aptamers and thrombin on GDMs is imaged by SECM with feedback mode using ferrocenemethanol as an electrochemical mediator. The formation of thrombin/thrombin aptamer complex on GDMs results in a decrease in the tip peak current on spatial SECM images. This method is able to linearly and selectively detect thrombin over a linear range from 10(-12) to 10(-5) M with a detection limit of 6.07 fM. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:333 / 335
页数:3
相关论文
共 26 条
[1]  
Azevedo J., 2012, ANAL CHEM
[2]  
Bard A., 2001, Scanning Electrochemical Microscopy
[3]   A simple electrochemical aptasensor for ultrasensitive protein detection using cyclic target-induced primer extension [J].
Cheng, Wei ;
Ding, Shijia ;
Li, Qing ;
Yu, Tianxiao ;
Yin, Yibin ;
Ju, Huangxian ;
Ren, Guosheng .
BIOSENSORS & BIOELECTRONICS, 2012, 36 (01) :12-17
[4]   The cyclic and linear sweep voltammetry of regular arrays of microdisc electrodes:: Fitting of experimental data [J].
Davies, TJ ;
Ward-Jones, S ;
Banks, CE ;
del Campo, J ;
Mas, R ;
Muñoz, FX ;
Compton, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 585 (01) :51-62
[5]   Parylene Insulated Probes for Scanning Electrochemical-Atomic Force Microscopy [J].
Derylo, Maksymilian A. ;
Morton, Kirstin C. ;
Baker, Lane A. .
LANGMUIR, 2011, 27 (22) :13925-13930
[6]   Surface patterning with fluorescent molecules using click chemistry directed by scanning electrochemical microscopy [J].
Ku, Sung-Yu ;
Wong, Ken-Tsung ;
Bard, Allen J. .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (08) :2392-2393
[7]   Aptamer biosensor for label-free impedance spectroscopy detection of thrombin based on gold nanoparticles [J].
Li, Li-Dong ;
Zhao, Hong-Tao ;
Chen, Zheng-Bo ;
Mu, Xiao-Jiao ;
Guo, Lin .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (01) :189-194
[8]   Molecularly Imprinted Aptamers of Gold Nanoparticles for the Enzymatic Inhibition and Detection of Thrombin [J].
Liao, Yu-Ju ;
Shiang, Yen-Chun ;
Huang, Chih-Ching ;
Chang, Huan-Tsung .
LANGMUIR, 2012, 28 (24) :8944-8951
[9]   Nanomechanics of surface DNA switches probed by captive contact angle [J].
Maiolo, Daniele ;
Federici, Stefania ;
Ravelli, Lorenzo ;
Depero, Laura E. ;
Hamad-Schifferli, Kimberly ;
Bergese, Paolo .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2013, 402 :334-339
[10]   A sensitive and selective thrombin impedimetric aptasensor based on tailored aptamers obtained by solid-phase synthesis [J].
Meini, N. ;
Farre, C. ;
Chaix, C. ;
Kherrat, R. ;
Dzyadevych, S. ;
Jaffrezic-Renault, N. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 :715-720