How far is how far enough? Safety perception and acceptance of extra-high-voltage power lines in Germany

被引:5
|
作者
Wiedemann, Peter M. [1 ]
Boerner, Franziska [2 ]
Claus, Frank [3 ]
机构
[1] Univ Wollongong, Sch Psychol, Wollongong, NSW, Australia
[2] Karlsruhe Inst Technol, Inst Technol Assessment & Syst Anal ITAS, Karlsruhe, Germany
[3] IKU, Dortmund, Germany
关键词
power lines; acceptance; safety perception; precautionary information; CHILDHOOD-CANCER; RISK COMPARISONS; PERCEIVED RISKS; MOBILE PHONES; EMF; POLICY;
D O I
10.1080/13669877.2016.1220415
中图分类号
C [社会科学总论];
学科分类号
03 ; 0303 ;
摘要
The results of a 2x2 factorial online experiment are reported. The first factor refers to the information on precautionary measures and the second factor on the information regarding the share of EMF exposure from extra-high-voltage power lines compared to overall EMF exposure measured in-house. The study is based on a community sample of 440 subjects. Information on the share of EMF exposure from extra-high-voltage power lines at the in-house overall EMF exposure has no statistically significant effect of safety distances and acceptance distances. Further findings indicate that communications of precautionary measures produce a countervailing effect: on average, subjects require a higher distance from their homes compared to those who were not informed about precautionary measures. However, there is also a positive effect of precautionary information on the acceptance belief. Subjects who received this information are, in average, less negative about the claim that compliance with the value limit is sufficient in order to agree with the construction of a power line. Possible explanations of the findings such as cognitive dissonance, negativity bias, and style of information processing are discussed.
引用
收藏
页码:463 / 479
页数:17
相关论文
共 6 条
  • [1] How far should bees be located from the high voltage power lines.?
    Lipinski, Zbigniew
    JOURNAL OF APICULTURAL RESEARCH, 2006, 45 (04) : 240 - 242
  • [2] DEVELOPMENT OF LASER CURRENT TRANSFORMER FOR EXTRA-HIGH-VOLTAGE POWER TRANSMISSION LINES
    SAITO, S
    HAMASAKI, J
    FUJII, Y
    YOKOYAMA, K
    OHNO, Y
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1967, QE 3 (11) : 589 - &
  • [3] Possible mechanism of lightning strokes to extra-high-voltage power transmission lines
    Makalsky, LM
    Orlov, AV
    Temnikov, AG
    JOURNAL OF ELECTROSTATICS, 1996, 37 (04) : 249 - 260
  • [4] The Effect of Resection Margin on Local Recurrence and Survival in High Grade Soft Tissue Sarcoma of the Extremities: How Far Is Far Enough?
    Bilgeri, Annika
    Klein, Alexander
    Lindner, Lars H.
    Nachbichler, Silke
    Knoesel, Thomas
    Birkenmaier, Christof
    Jansson, Volkmar
    Baur-Melnyk, Andrea
    Duerr, Hans Roland
    CANCERS, 2020, 12 (09) : 1 - 13
  • [5] Corona power loss modelling for extra-high-voltage overhead transmission lines in steady-state condition
    Balametov, A.B.
    Elektrichestvo, 1995, (10): : 22 - 28
  • [6] Sensing absorption lines from the interstellar and intergalactic media at high signal-to-noise and resolution: How far can we go?
    Jenkins, EB
    HUBBLE'S SCIENCE LEGACY: FUTURE OPTICAL/ULTRAVIOLET ASTRONOMY FROM SPACE, 2003, 291 : 391 - 394