A Novel Adaptive Dispersed Phase Current Differential Protection Criterion

被引:0
|
作者
Wang, Chunfeng [1 ]
Lu, Yuping [1 ]
Xiao, Nan [1 ]
Cai, Chao [1 ]
机构
[1] Southeast Univ, Sch Elect Engn, Nanjing 210096, Jiangsu, Peoples R China
关键词
current differential protection; adaptive; through current; line protection; heavy load; transient resistances;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper indicates that the sensitivity of conventional dispersed phase current differential protection criterion using steady currents is impressed by the transient resistances and through currents. A novel adaptive dispersed phase current differential protection criterion is proposed in this paper, and an objective function with the independent variable of fault current component and through current is defined to revise the restraining ratio of differential protection criterion adaptively. The novel criterion possesses higher sensitivity at an internal ground fault with high transient resistances and heavy-loads. It can automatically decrease the restraint coefficients according to the transient resistances and improve the sensitivity at internal faults, while increase them at the external faults adaptively. The comparative analysis of the acting characteristic between the novel and conventional criterion is taken. Simulation results show the feasibility and effectiveness of the novel criterion proposed.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Analysis on the current phase compensation methods in differential protection for transformer
    State Key Lab of Power Systems, Department of Electrical Engineering, Tsinghua University, Beijing 100084, China
    不详
    Dianli Xitong Zidonghue, 2006, 18 (33-37):
  • [32] Phase correlation current differential protection based on fault component
    Li, Bin
    Zeng, Hongyan
    Fan, Ruiqing
    Bo, Zhiqian
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2011, 35 (03): : 54 - 58
  • [33] A Novel Current Differential Protection Scheme for Active Distribution Networks
    Guo, Xuelin
    Wang, Liyan
    Sun, Liangzhi
    Han, Rui
    Sun, Xiangming
    Zang, Lindong
    Zhou, Chenghan
    Zou, Guibin
    2020 IEEE STUDENT CONFERENCE ON ELECTRIC MACHINES AND SYSTEMS (SCEMS 2020), 2020, : 66 - 70
  • [34] Novel wavelet approach to current differential pilot relay protection
    Wong, CK
    Lam, CW
    Lei, KC
    Lei, CS
    Han, YD
    IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (01) : 20 - 25
  • [35] Novel wavelet approach to current differential pilot relay protection
    Wong, CK
    Lam, CW
    Lei, KC
    Lei, CS
    Han, YD
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 34 - 34
  • [36] Novel Differential Protection for a Powerformer Considering Capacitive Current Compensation
    Wang, Yuanyuan
    Luo, Xiaomin
    Zeng, Xiangjun
    Zhou, Lawu
    Ye, Yuxuan
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (05) : 3169 - 3178
  • [37] A novel algorithm of regional backup protection using adaptive current protection suiting factor
    Ma, Jing
    Xiang, Xiaoqiang
    Kang, Wenbo
    Thorp, James S.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2017, 27 (11):
  • [38] A Novel Sufficient Differential Criterion of Current Amplitude for Distribution Network with Distributed Generators
    Zhang, Zhen
    Lu, Yu-ping
    Li, Ran
    2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,
  • [39] A novel criterion applicable to transformer differential protection based on waveform sinusoidal similarity identification
    Weng, Hanli
    Wang, Sheng
    Lin, Xiangning
    Li, Zhenxing
    Huang, Jingguang
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 105 : 305 - 314
  • [40] Optimizing the operation of current differential protection by power differential relay for three phase transformer
    Bahmani, B
    Nafar, M
    Ranjbar, AM
    Proceedings of the 4th WSEAS International Conference on Applications of Electrical Engineering, 2005, : 378 - 383