What factors predict ceramic liner malseating after ceramic-on-ceramic total hip arthroplasty?

被引:7
作者
Higuchi, Yoshitoshi [1 ]
Seki, Taisuke [1 ]
Takegami, Yasuhiko [1 ]
Osawa, Yusuke [1 ]
Kusano, Taiki [1 ]
Ishiguro, Naoki [1 ]
机构
[1] Nagoya Univ, Dept Orthopaed Surg, Grad Sch Med, Showa Ku, 65 Tsurumai Cho, Nagoya, Aichi 4668550, Japan
关键词
Ceramic on ceramic bearings; Total hip arthroplasty; Liner malseating; Risk factor; Ceramic liner with a metal-back titanium; sleeve; OSTEOARTHRITIS; SURVIVORSHIP; BEARING;
D O I
10.1016/j.otsr.2019.01.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: There is a lack of evidence about the risk factors associated with the malseating of the acetabular liner after ceramic-on-ceramic (CoC) total hip arthroplasty (THA). Therefore, we performed a complementary retrospective case-control study to determine the factors predicting the malseating of the acetabular liner after CoC THA and to evaluate the relationship between malseating and (1) osteoarthritis, (2) particularly in terms of the new radiographic parameter "bone sclerotic length" of the acetabular bone. Hypothesis: Osteoarthritis, particularly bone sclerotic length, was an independent risk factor for malseating of ceramic liners. Patients and methods: In total, 219 CoC THAs (174 women and 45 men) were evaluated to determine the risk factors influencing the malseating of the acetabular ceramic liner. An average patient age at the time of surgery was 55.9 +/- 9.5 years (range, 23 to 75 years). Data on patient background and preoperative radiographs, such as Tonnis grades; Crowe classification; and indices of acetabular osteoarthritis change; including bone cyst, osteophyte and bone sclerosis, were assessed. The bone sclerotic length in patients with osteoarthritis was measured as the slant distance between the bilateral edges of the sclerosis lesion of the acetabulum on the anteroposterior view. Results: Preoperative less hip flexion (hazard ratio [HR]: 0.98; 95% CI: 0.97-0.99), osteoarthritis (HR: 3.15; 95% CI: 1.02-9.70) and the bone sclerotic length (HR: 1.83; 95% CI: 1.35-2.48) were independent risk factors determining the malseating of ceramic liners. Receiver operating characteristic curve analysis showed that a bone sclerotic length of 24.6 mm was defined as the cut-off point for the malseating of the ceramic liner. Discussion: Age, preoperative less flextion, osteoarthritis, and the bone sclerotic were independent risk factors determining malseating of ceramic liners. The acetabular shell can also deform upon insertion of the cup with sclerotic bone of the acetabulum and prevent correct seating of liners. Therefore, these factors must be taken into consideration when seating the ceramic liner. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:453 / 459
页数:7
相关论文
共 24 条
  • [1] THE AMERICAN-COLLEGE-OF-RHEUMATOLOGY CRITERIA FOR THE CLASSIFICATION AND REPORTING OF OSTEOARTHRITIS OF THE HIP
    ALTMAN, R
    ALARCON, G
    APPELROUTH, D
    BLOCH, D
    BORENSTEIN, D
    BRANDT, K
    BROWN, C
    COOKE, TD
    DANIEL, W
    FELDMAN, D
    GREENWALD, R
    HOCHBERG, M
    HOWELL, D
    IKE, R
    KAPILA, P
    KAPLAN, D
    KOOPMAN, W
    MARINO, C
    MCDONALD, E
    MCSHANE, DJ
    MEDSGER, T
    MICHEL, B
    MURPHY, WA
    OSIAL, T
    RAMSEYGOLDMAN, R
    ROTHSCHILD, B
    WOLFE, F
    [J]. ARTHRITIS AND RHEUMATISM, 1991, 34 (05): : 505 - 514
  • [2] THE USE OF DENSE ALUMINA ALUMINA CERAMIC COMBINATION IN TOTAL HIP-REPLACEMENT
    BOUTIN, P
    CHRISTEL, P
    DORLOT, JM
    MEUNIER, A
    DEROQUANCOURT, A
    BLANQUAERT, D
    HERMAN, S
    SEDEL, L
    WITVOET, J
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (12): : 1203 - 1232
  • [3] Ceramic-on-Ceramic Total Hip Arthroplasty: Update
    Capello, William N.
    D'Antonio, James A.
    Feinberg, Judy R.
    Manley, Michael T.
    Naughton, Marybetb
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07) : 39 - 43
  • [4] Carvajal Alba Jaime A, 2010, Orthopedics, V33, P15, DOI 10.3928/01477447-20091124-11
  • [5] TOTAL HIP-REPLACEMENT IN CONGENITAL DISLOCATION AND DYSPLASIA OF THE HIP
    CROWE, JF
    MANI, VJ
    RANAWAT, CS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (01) : 15 - 23
  • [6] Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 Years
    D'Antonio, James A.
    Capello, William N.
    Naughton, Marybeth
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (02) : 373 - 381
  • [7] Fracture of the ABC® ceramic liner -: A report of three cases
    Diwanji, Sanket R.
    Seon, Jong Kenn
    Song, Eun. Kyoo
    Yoon, Taek Rim
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (464) : 242 - 246
  • [8] Minimum Lateral Bone Coverage Required for Securing Fixation of Cementless Acetabular Components in Hip Dysplasia
    Fujii, Masanori
    Nakashima, Yasuharu
    Nakamura, Tetsuro
    Ito, Yoshihiro
    Hara, Toshihiko
    [J]. BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [9] Incidence of Ceramic Liner Malseating After Ceramic-on-Ceramic Total Hip Arthroplasty Associated With Osteolysis: A 5-to 15-Year Follow-Up Study
    Higuchi, Yoshitoshi
    Hasegawa, Yukiharu
    Komatsu, Daigo
    Seki, Taisuke
    Ishiguro, Naoki
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (05) : 1641 - 1646
  • [10] Survivorship Between 2 Different Ceramic-on-Ceramic Total Hip Arthroplasty With or Without a Metal-Backed Titanium Sleeve Bearing: A 5-to 14-Year Follow-Up Study
    Higuchi, Yoshitoshi
    Hasegawa, Yukiharu
    Komatsu, Daigo
    Seki, Taisuke
    Ishiguro, Naoki
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (01) : 155 - 160