Interpretation of Recovery Voltage mechanisms in Performance of solid insulation system in power transformer

被引:0
|
作者
Aruna, M. [1 ]
Vasudev, N. [2 ]
Ravi, K. N. [3 ]
Poovamma, P. K. [2 ]
机构
[1] Acharya Inst Technol, Bangalore, Karnataka, India
[2] Cent Power Res Inst, Bangalore, Karnataka, India
[3] Sapthagiri Coll Engn, Bangalore, Karnataka, India
关键词
Solid and liquid insulations; ageing studies; Recovery Voltage Measurement;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with evaluation of the moisture content in the insulation of power transformer. There is an occurrence of Polarization that leads to chemical variations in the insulation and conduction instigated due to the occurrence of impurities or contaminants in the insulation system. Moisture, oxygen, high temperature and contaminations of these are the vital parameters leading to the failure of the transformer. This in turn mainly reduces the dielectric strength of the solid insulation system and with an increase in temperature may deteriorate the insulation strength as it ages. The main factor for deterioration is moisture. This paper discusses the experimental method and results of Recover voltage measurement in order to assess the moisture content. The different samples considered for experimental analysis are Kraft and Aramid of paper insulation and Novel G-Paek of polymer insulations.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] High Voltage Power Transformer Insulation Design
    Ziomek, W.
    Vijayan, K.
    Boyd, D.
    Kuby, K.
    Franchek, M.
    2011 ELECTRICAL INSULATION CONFERENCE (EIC), 2011, : 211 - 215
  • [2] Synthetic evaluation of solid insulation for power transformer
    Qian, Zheng
    Shang, Yong
    Yang, Li
    Yan, Zhang
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2000, 34 (04): : 5 - 9
  • [3] Novel Insulation system in power transformer
    Aruna, M.
    Vasudev, N.
    Ravi, K. N.
    Pattanshetti, V. V.
    2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM), 2012,
  • [4] Diagnosis of transformer insulation condition using recovery voltage measurements
    Talib, MA
    Ghazali, NAM
    Christie, M
    Zakaria, W
    Hashim, I
    Uthman, S
    Jamali, MN
    NATIONAL POWER ENGINEERING CONFERENCE PECON 2003, PROCEEDINGS, 2003, : 329 - 332
  • [5] Influence of acid value on recovery voltage parameters of transformer oil-paper insulation system
    Wang, X. (xjwang1987@126.com), 1600, Electric Power Automation Equipment Press (33):
  • [6] Investigation on Degradation of Power Transformer Solid Insulation Material
    Homagk, C.
    Moessner, K.
    Leibfried, T.
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 268 - 271
  • [7] Monitoring and Diagnostic Techniques of Power Transformer Solid Insulation
    Wang, Jie
    Zheng, Jian
    Hu, Shuilian
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 77 - 80
  • [8] Condition Monitoring of Power Transformer Insulation by Return Voltage Measurement
    Soni, Gajanand
    Dutta, Saurabh
    Baral, Arijit
    PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 108 - 112
  • [9] STATISTICAL ANALYSIS OF ELECTRICAL AND MECHANICAL BREAKDOWN STRESS FOR INSULATION PERFORMANCE IN HIGH VOLTAGE POWER TRANSFORMER
    Pamuk, Nihat
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2014, 21 (03): : 495 - 503
  • [10] DISCUSSION ON HIGH-VOLTAGE POWER-TRANSFORMER INSULATION
    TAYLOR, FW
    LEECH, GN
    HEIGHES, J
    FEINBERG, R
    WAINWRIG.J
    WOODHOUS.JS
    WEST, JH
    REED, JH
    RYDER, DH
    WATSON, GP
    THOMPSON, WG
    BRADLEY, RS
    BEGENT, HH
    SMITH, DH
    GRIERSON, RA
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1965, 112 (01): : 119 - &