Peptide Biosensors for the Electrochemical Measurement of Protein Kinase Activity

被引:79
|
作者
Kerman, Kagan [1 ]
Song, Haifeng [1 ]
Duncan, James S. [2 ]
Litchfield, David W. [2 ]
Kraatz, Heinz-Bernhard [1 ]
机构
[1] Univ Western Ontario, Dept Chem, Fac Sci, London, ON N6A 5B7, Canada
[2] Univ Western Ontario, Schulich Sch Med & Dent, Dept Biochem, London, ON N6A 5B7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1021/ac801208e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The kinase activities are elucidated using the novel redox-active cosubstrate adenosine 5'-[gamma-ferrocene] triphosphate (Fc-ATP), which enables the kinase-catalyzed transfer of a redox active gamma-phosphate-Fc to a hydroxyamino acid. In this report, a versatile electrochemical biosensor is developed for monitoring the activity and inhibition of a serine/threonine kinase, casein kinase 2 (CK2), and protein tyrosine kinases, Abl1-T315I and HER2, in buffered solutions and in cell lysates. The method is based on the labeling of a specific phosphorylation event with Fc, followed by electrochemical detection. The electrochemical response obtained from the "ferrocenylated" peptides enables monitoring the activity of the kinase and its substrate, as well as the inhibition of small molecule inhibitors on protein phosphorylation. Kinetic information was extracted from the electrochemical measurements for the determination of K-m and V-m values, which were in agreement with those previously reported. Kinase reactions were also performed in the presence of well-defined inhibitors of CK2, 4,5,6,7-tetrabromo-2-azabenzimidazole, 2-dimethylamino-4,5,6,7-tetrabromo-1H-benzimidazole, and E-3-(2,3,4,5-tetrabromophenyl)acrylic acid as well as the nonspecific kinase inhibitors, staurosporine and N-benzoylstaurosporine. On the basis of the dependency of the Fc signal on inhibitor concentration, K-i of the inhibitors was estimated, which were also in agreement with the literature values. The performance of the biosensor was optimized including the kinase reaction, incubation with Fc-ATP, and the small molecule inhibitors. Peptide modified electrochemical biosensors; are promising candidates for cost-effective in vitro kinase activity and inhibitor screening assays.
引用
收藏
页码:9395 / 9401
页数:7
相关论文
共 50 条
  • [21] Electrochemical biosensors for measurement of colorectal cancer biomarkers
    Zhang, Wenxian
    Xiao, Guangchun
    Chen, Jun
    Wang, Li
    Hu, Qiongzheng
    Wu, Jian
    Zhang, Wenhong
    Song, Ming
    Qiao, Jinwei
    Xu, Chonghai
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (09) : 2407 - 2428
  • [22] Enzymatic electrochemical biosensors for in situ neurochemical measurement
    Pan, Cong
    Wei, Huan
    Han, Zhongjie
    Wu, Fei
    Mao, Lanqun
    CURRENT OPINION IN ELECTROCHEMISTRY, 2020, 19 : 162 - 167
  • [23] Review of electrochemical and optical biosensors for testosterone measurement
    Nikkhah, Maryam
    Karami, Sajedeh
    Khatami, Seyyed Hossein
    Taheri-Anganeh, Mortaza
    Savardashtaki, Amir
    Mahmoodzadeh, Amir
    Shabaninejad, Zahra
    Vakili, Omid
    Mousavi, Pegah
    Ghanizadeh Gerayeli, Farhad
    Behrouj, Hamid
    Ghasemi, Hassan
    Movahedpour, Ahmad
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2023, 70 (01) : 318 - 329
  • [24] Electrochemical biosensors for measurement of colorectal cancer biomarkers
    Wenxian Zhang
    Guangchun Xiao
    Jun Chen
    Li Wang
    Qiongzheng Hu
    Jian Wu
    Wenhong Zhang
    Ming Song
    Jinwei Qiao
    Chonghai Xu
    Analytical and Bioanalytical Chemistry, 2021, 413 : 2407 - 2428
  • [25] Complex Peptide Biosensors for Detection of Intracellular Kinase Biomarkers
    Morris, May C.
    Kurzawa, Laetitia
    Van, Ngoc
    Pellerano, Morgan
    FASEB JOURNAL, 2012, 26
  • [26] DNA Assembled Gold Nanoparticles Polymeric Network Blocks Modular Highly Sensitive Electrochemical Biosensors for Protein Kinase Activity Analysis and Inhibition
    Wang, Zonghua
    Sun, Na
    He, Yao
    Liu, Yang
    Li, Jinghong
    ANALYTICAL CHEMISTRY, 2014, 86 (12) : 6153 - 6159
  • [27] In vitro protein kinase activity measurement by flow cytometry
    Bernsteel, Donald J.
    Roman, David L.
    Neubig, Richard R.
    ANALYTICAL BIOCHEMISTRY, 2008, 383 (02) : 180 - 185
  • [28] A Peptide Microarray for the Detection of Protein Kinase Activity in Cell Lysate
    Syuhei Shigaki
    Takayuki Yamaji
    Xiaoming Han
    Go Yamanouchi
    Tatsuhiko Sonoda
    Osamu Okitsu
    Takeshi Mori
    Takuro Niidome
    Yoshiki Katayama
    Analytical Sciences, 2007, 23 : 271 - 275
  • [29] A peptide microarray for the detection of protein kinase activity in cell lysate
    Shigaki, Syuhei
    Yamaji, Takayuki
    Han, Xiaoming
    Yamanouchi, Go
    Sonoda, Tatsuhiko
    Okitsu, Osamu
    Mori, Takeshi
    Niidome, Takuro
    Katayama, Yoshiki
    ANALYTICAL SCIENCES, 2007, 23 (03) : 271 - 275
  • [30] THE DIRECT MEASUREMENT OF PROTEIN-KINASE-C (PKC) ACTIVITY IN ISOLATED MEMBRANES USING A SELECTIVE PEPTIDE SUBSTRATE
    CHAKRAVARTHY, BR
    BUSSEY, A
    WHITFIELD, JF
    SIKORSKA, M
    WILLIAMS, RE
    DURKIN, JP
    ANALYTICAL BIOCHEMISTRY, 1991, 196 (01) : 144 - 150