Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs

被引:112
作者
Weng, Dietmar [1 ]
Hitomi Nagata, Maria Jose [2 ]
Bell, Matthias [1 ]
Bosco, Alvaro Francisco [2 ]
Nascimento de Melo, Luiz Gustavo [2 ]
Richter, Ernst-Juergen [1 ]
机构
[1] Univ Wurzburg, Sch Dent Med, Dept Prosthodont, Wurzburg, Germany
[2] Sao Paulo State Univ Julio de Mesquita Filho UNES, Dept Surg & Integrated Clin, Dent Sch Araccatuba, Div Periodont, Sao Paulo, Brazil
关键词
bone morphology; equicrestal placement; histometric study; microgap; subcrestal placement;
D O I
10.1111/j.1600-0501.2008.01564.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared. Material and methods: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect. Results: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23mm; TIU equicrestal -0.51mm; ANK subcrestal +0.19mm; TIU subcrestal -0.57mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted. Conclusions: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.
引用
收藏
页码:1141 / 1147
页数:7
相关论文
共 22 条
  • [1] Peri-implant tissues at submerged and non-submerged titanium implants
    Abrahamsson, I
    Berglundh, T
    Moon, IS
    Lindhe, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1999, 26 (09) : 600 - 607
  • [2] Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
  • [3] Dibart S, 2005, INT J ORAL MAX IMPL, V20, P732
  • [4] A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE
    DONATH, K
    BREUNER, G
    [J]. JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) : 318 - 326
  • [5] Radiographical and histological characteristics of submerged and non-submerged titanium implants - An experimental study in the Labrador dog
    Ericsson, I
    Nilner, K
    Klinge, B
    Glantz, PO
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (01) : 20 - 26
  • [6] Comparison of implant survival following sinus floor augmentation procedures with implants placed in pristine posterior maxillary bone: a systematic review
    Graziani, F
    Donos, N
    Needleman, I
    Gabriele, M
    Tonetti, M
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (06) : 677 - 682
  • [7] Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandible
    Hermann, JS
    Cochran, DL
    Nummikoski, PV
    Buser, D
    [J]. JOURNAL OF PERIODONTOLOGY, 1997, 68 (11) : 1117 - 1130
  • [8] Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandible
    Hermann, JS
    Schoolfield, JD
    Schenk, RK
    Buser, D
    Cochran, DL
    [J]. JOURNAL OF PERIODONTOLOGY, 2001, 72 (10) : 1372 - 1383
  • [9] Crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged and submerged implants in the canine mandible
    Hermann, JS
    Buser, D
    Schenk, RK
    Cochran, DL
    [J]. JOURNAL OF PERIODONTOLOGY, 2000, 71 (09) : 1412 - 1424
  • [10] Influence of smoking on osseointegrated implant failure: a meta-analysis
    Hinode, Daisuke
    Tanabe, Shin-ichi
    Yokoyama, Masaaki
    Fujisawa, Kenji
    Yamauchi, Eiji
    Miyamoto, Youji
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (04) : 473 - 478