A modified method for estimation of chemical oxygen demand for samples having high suspended solids

被引:21
|
作者
Yadvika
Yadav, AK
Sreekrishnan, TR
Satya, S [1 ]
Kohli, S
机构
[1] Indian Inst Technol, Ctr Rural Dev & Technol, New Delhi 110016, India
[2] Indian Inst Technol, Dept Biochem Engn & Biotechnol, New Delhi 110016, India
[3] Indian Inst Technol, Dept Mech Engn, New Delhi 110016, India
关键词
COD estimation; cattle dung; slurry; suspended solids; heterogeneous substrates;
D O I
10.1016/j.biortech.2005.04.013
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
Determination of chemical oxygen demand (COD) of samples having high suspended solids concentration such as cattle dung slurry with open reflux method of APHA-AWWA-WPCF did not give consistent results. This study presents a modification of the open reflux method (APHA-AWWA-WPCF) to make it suitable for samples with high percentage of suspended solids. The new method is based on a different technique of sample preparation, modified quantities of reagents and higher reflux time as compared to the existing open reflux method. For samples having solids contents of 14.0 g/l or higher, the modified method was found to give higher value of COD with much higher consistency and accuracy as compared to the existing open reflux method. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:721 / 726
页数:6
相关论文
共 50 条
  • [1] A modified method for the determination of chemical oxygen demand (COD) for samples with high salinity and low organics
    Vyrides, I.
    Stuckey, D. C.
    BIORESOURCE TECHNOLOGY, 2009, 100 (02) : 979 - 982
  • [2] Estimation of the maximum consumption of permanganate by aquifer solids using a modified chemical oxygen demand test
    Xu, Xiuyuan
    Thomson, Neil R.
    JOURNAL OF ENVIRONMENTAL ENGINEERING, 2008, 134 (05) : 353 - 361
  • [3] Assessment of a modified and optimised method for determining chemical oxygen demand of solid substrates and solutions with high suspended solid content
    Raposo, F.
    de la Rubia, M. A.
    Borja, R.
    Alaiz, M.
    TALANTA, 2008, 76 (02) : 448 - 453
  • [4] A multihydrocyclone water pretreatment system to reduce suspended solids and the chemical oxygen demand
    Son, Jong Hwa
    Hong, Min
    Yoo, Han Cheol
    Kim, Young Im
    Kim, Hea Do
    Kim, Ji Tae
    DESALINATION AND WATER TREATMENT, 2016, 57 (07) : 2996 - 3001
  • [5] A Novel Composite Polymer for Chemical Oxygen Demand and Total Suspended Solids Removal
    Al-Ani, Yasir
    Rajab, Ahmed Rahomi
    Ismael, Zainab Malik
    12TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENTS IN ESYSTEMS ENGINEERING (DESE 2019), 2019, : 571 - 575
  • [6] METHOD FOR ISOLATING SUSPENDED SOLIDS FROM SEWAGE EFFLUENTS FOR MEASUREMENT OF OXYGEN DEMAND
    MONTGOMERY, HA
    WATER RESEARCH, 1972, 6 (09) : 1097 - +
  • [7] Accuracy of different sensors for the estimation of pollutant concentrations (total suspended solids, total and dissolved chemical oxygen demand) in wastewater and stormwater
    Lepot, Mathieu
    Aubin, Jean-Baptiste
    Bertrand-Krajewski, Jean-Luc
    WATER SCIENCE AND TECHNOLOGY, 2013, 68 (02) : 462 - 471
  • [8] Modified filtration method for suspended solids analysis
    Harada Jr, H.M.
    Reid, G.H.
    Bennett, E.R.
    Linstedt, K.D.
    1853, (45):
  • [9] MODIFIED FILTRATION METHOD FOR SUSPENDED SOLIDS ANALYSIS
    HARADA, HM
    REID, GH
    BENNETT, ER
    LINSTEDT, KD
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1973, 45 (09): : 1853 - 1858
  • [10] Determination of chemical oxygen demand of high concentration chloride water samples by silver precipitation and dichromate method
    Binzhou Environmental Monitoring Station, Binzhou 256618, China
    Yejin Fenxi, 2008, 3 (43-45):