A comparison of power measuring systems

被引:5
作者
Simonson, P
Svensson, S
Rydler, KE
机构
[1] Swedish National Testing and Research Institute
关键词
automated; measuring system; phase; power; precision; wattmeter; zero power factor;
D O I
10.1109/19.571873
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An automatic zero-power-factor standard has been designed and compared with a digital sampling wattmeter standard. The agreement of the two power measuring standards at 120 V, 5 A, and zero power factor is within a few mu W/VA. The paper describes the standards, the phase errors and uncertainties of the two standards.
引用
收藏
页码:423 / 425
页数:3
相关论文
共 2 条
[1]   A SIMPLE ZERO-POWER-FACTOR REFERENCE-STANDARD WITH AN UNCERTAINTY OF 1-PPM [J].
INGLIS, BD ;
GIBBES, AM ;
FIANDER, JR .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1987, 36 (02) :369-374
[2]   A MEASURING SYSTEM FOR THE CALIBRATION OF POWER ANALYZERS [J].
SVENSSON, S ;
RYDLER, KE .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1995, 44 (02) :316-317