A feasibility study of X-ray phase-contrast mammographic tomography at the Imaging and Medical beamline of the Australian Synchrotron

被引:38
作者
Nesterets, Yakov I. [1 ,2 ]
Gureyev, Timur E. [1 ,2 ,3 ,4 ]
Mayo, Sheridan C. [1 ]
Stevenson, Andrew W. [1 ,5 ]
Thompson, Darren [1 ,2 ]
Brown, Jeremy M. C. [4 ]
Kitchen, Marcus J. [4 ]
Pavlov, Konstantin M. [2 ,4 ]
Lockie, Darren [6 ]
Brun, Francesco [7 ,8 ]
Tromba, Giuliana [8 ]
机构
[1] Commonwealth Sci & Ind Res Org, Melbourne, Vic, Australia
[2] Univ New England, Sch Sci & Technol, Armidale, NSW, Australia
[3] Univ Melbourne, Sch Phys, ARC Ctr Excellence Adv Mol Imaging, Parkville, Vic 3052, Australia
[4] Monash Univ, Sch Phys & Astron, Melbourne, Vic 3004, Australia
[5] Australian Synchrotron, Melbourne, Vic, Australia
[6] Maroondah BreastScreen, Melbourne, Vic, Australia
[7] Univ Trieste, Dept Engn & Architecture, Trieste, Italy
[8] Elettra Sincrotrone Trieste SCpA, Trieste, Italy
基金
澳大利亚研究理事会;
关键词
X-rays; phase contrast; computed tomography; mammography; HIGH-RESOLUTION; BREAST; TOMOSYNTHESIS; OPTIMIZATION; RETRIEVAL; NOISE;
D O I
10.1107/S160057751501766X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Results are presented of a recent experiment at the Imaging and Medical beamline of the Australian Synchrotron intended to contribute to the implementation of low-dose high-sensitivity three-dimensional mammographic phase-contrast imaging, initially at synchrotrons and subsequently in hospitals and medical imaging clinics. The effect of such imaging parameters as X-ray energy, source size, detector resolution, sample-to-detector distance, scanning and data processing strategies in the case of propagation-based phase-contrast computed tomography (CT) have been tested, quantified, evaluated and optimized using a plastic phantom simulating relevant breast-tissue characteristics. Analysis of the data collected using a Hamamatsu CMOS Flat Panel Sensor, with a pixel size of 100 mm, revealed the presence of propagation-based phase contrast and demonstrated significant improvement of the quality of phase-contrast CT imaging compared with conventional (absorption-based) CT, at medically acceptable radiation doses.
引用
收藏
页码:1509 / 1523
页数:15
相关论文
共 30 条
[1]  
[Anonymous], P SPIE
[2]   Interface-specific x-ray phase retrieval tomography of complex biological organs [J].
Beltran, M. A. ;
Paganin, D. M. ;
Siu, K. K. W. ;
Fouras, A. ;
Hooper, S. B. ;
Reser, D. H. ;
Kitchen, M. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (23) :7353-7369
[3]   X-ray phase-contrast imaging: from pre-clinical applications towards clinics [J].
Bravin, Alberto ;
Coan, Paola ;
Suortti, Pekka .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (01) :R1-R35
[4]   Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study [J].
Ciatto, Stefano ;
Houssami, Nehmat ;
Bernardi, Daniela ;
Caumo, Francesca ;
Pellegrini, Marco ;
Brunelli, Silvia ;
Tuttobene, Paola ;
Bricolo, Paola ;
Fanto, Carmine ;
Valentini, Marvi ;
Montemezzi, Stefania ;
Macaskill, Petra .
LANCET ONCOLOGY, 2013, 14 (07) :583-589
[5]   MONTE-CARLO CALCULATION OF CONVERSION FACTORS FOR THE ESTIMATION OF MEAN GLANDULAR BREAST DOSE [J].
DANCE, DR .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (09) :1211-1219
[6]   Analytical and experimental determination of signal-to-noise ratio and figure of merit in three phase-contrast imaging techniques [J].
Diemoz, P. C. ;
Bravin, A. ;
Langer, M. ;
Coan, P. .
OPTICS EXPRESS, 2012, 20 (25) :27670-27690
[7]   Investigation of the imaging quality of synchrotron-based phase-contrast mammographic tomography [J].
Gureyev, T. E. ;
Mayo, S. C. ;
Nesterets, Ya I. ;
Mohammadi, S. ;
Lockie, D. ;
Menk, R. H. ;
Arfelli, F. ;
Pavlov, K. M. ;
Kitchen, M. J. ;
Zanconati, F. ;
Dullin, C. ;
Tromba, G. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2014, 47 (36)
[8]   Image deblurring by means of defocus [J].
Gureyev, TE ;
Stevenson, AW ;
Nesterets, YI ;
Wilkins, SW .
OPTICS COMMUNICATIONS, 2004, 240 (1-3) :81-88
[9]   Accuracy and precision of reconstruction of complex refractive index in near-field single-distance propagation-based phase-contrast tomography [J].
Gureyev, Timur ;
Mohammadi, Sara ;
Nesterets, Yakov ;
Dullin, Christian ;
Tromba, Giuliana .
JOURNAL OF APPLIED PHYSICS, 2013, 114 (14)
[10]   Duality between noise and spatial resolution in linear systems [J].
Gureyev, Timur E. ;
Nesterets, Yakov I. ;
de Hoog, Frank ;
Schmalz, Gerd ;
Mayo, Sheridan C. ;
Mohammadi, Sara ;
Tromba, Giuliana .
OPTICS EXPRESS, 2014, 22 (08) :9087-9094