Assessment of cup orientation in hip resurfacing: a comparison of TraumaCad and computed tomography

被引:40
作者
Westacott, Daniel J. [1 ]
McArthur, John [1 ]
King, Richard J. [1 ]
Foguet, Pedro [1 ]
机构
[1] Univ Hosp Coventry & Warwickshire, Warwick Orthopaed, Coventry, W Midlands, England
关键词
Hip; Resurfacing; Orientation; Version; Software; ACETABULAR ORIENTATION; PLAIN RADIOGRAPHS; METAL; ARTHROPLASTY; COMPONENT; ANGLE; IMPINGEMENT; ANTEVERSION; SIZE; IONS;
D O I
10.1186/1749-799X-8-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The orientation of the acetabular component in metal-on-metal hip resurfacing arthroplasty affects wear rate and hence failure. This study aimed to establish if interpretation of pelvic radiographs with TraumaCad software can provide a reliable alternative to CT in measuring the acetabular inclination and version. Methods: TraumaCad was used to measure the acetabular orientation on AP pelvis radiographs of 14 painful hip resurfacings. Four orthopaedic surgeons performed each measurement twice. These were compared with measurements taken from CT reformats. The correlation between TraumaCad and CT was calculated, as was the intra-and inter-observer reliability of TraumaCad. Results: There is strong correlation between the two techniques for the measurement of inclination and version (p < 0.001). Intra-and inter-observer reliability of TraumaCad measurements are good (p < 0.001). Mean absolute error for measurement of inclination was 2.1. TraumaCad underestimated version compared to CT in 93% of cases, by 12.6 degrees on average. Conclusions: When assessing acetabular orientation in hip resurfacing, the orthopaedic surgeon may use TraumaCad in the knowledge that it correlates well with CT and has good intra-and inter-observer reliability but underestimates version by 12 on average.
引用
收藏
页数:6
相关论文
共 19 条
[1]   Iliopsoas impingement on the acetabular component:: Radiologic and computed tomography findings of a rare prosthesis complication in eight cases [J].
Cyteval, C ;
Sarrabère, P ;
Cottin, A ;
Assi, C ;
Morcos, L ;
Maury, P ;
Taourel, P .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (02) :183-188
[2]   Revision of metal-on-metal resurfacing arthroplasty of the hip - The influence of malpositioning of the components [J].
De Haan, R. ;
Campbell, P. A. ;
Su, E. P. ;
De Smet, K. A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (09) :1158-1163
[3]   Surgical Variables Influence Metal Ion Levels After Hip Resurfacing [J].
Desy, Nicholas M. ;
Bergeron, Stephane G. ;
Petit, Alain ;
Huk, Olga L. ;
Antoniou, John .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (06) :1635-1641
[4]   Optimal acetabular orientation for hip resurfacing [J].
Grammatopoulos, G. ;
Pandit, H. ;
Glyn-Jones, S. ;
McLardy-Smith, P. ;
Gundle, R. ;
Whitwell, D. ;
Gill, H. S. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08) :1072-1078
[5]   The relationship between the angle of version and rate of wear of retrieved metal-on-metal resurfacings A PROSPECTIVE, CT-BASED STUDY [J].
Hart, A. J. ;
Ilo, K. ;
Underwood, R. ;
Cann, P. ;
Henckel, J. ;
Lewis, A. ;
Cobb, J. ;
Skinner, J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (03) :315-320
[6]   Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing [J].
Hart, A. J. ;
Buddhdev, P. ;
Winship, P. ;
Faria, N. ;
Powell, J. J. ;
Skinner, J. A. .
HIP INTERNATIONAL, 2008, 18 (03) :212-219
[7]   Large ball metal on metal hips obscure cup angle measurement on plain radiographs [J].
Hart, Alister J. ;
Dandachli, Wael ;
Schlueter-Brust, Klaus ;
Henckel, Johann ;
Cobb, Justin .
HIP INTERNATIONAL, 2009, 19 (04) :323-329
[8]   Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement [J].
Kalteis, T ;
Handel, M ;
Herold, T ;
Perlick, L ;
Paetzel, C ;
Grifka, J .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) :294-300
[9]   Limited range of motion of hip resurfacing arthroplasty due to unfavorable ratio of prosthetic head size and femoral neck diameter [J].
Kluess, Daniel ;
Zietz, Carmen ;
Lindner, Tobias ;
Mittelmeier, Wolfram ;
Schmitz, Klaus-Peter ;
Bader, Rainer .
ACTA ORTHOPAEDICA, 2008, 79 (06) :748-754
[10]   Analysis of wear of retrieved metal-on-metal hip resurfacing implants revised due to pseudotumours [J].
Kwon, Y. -M. ;
Glyn-Jones, S. ;
Simpson, D. J. ;
Kamali, A. ;
McLardy-Smith, P. ;
Gill, H. S. ;
Murray, D. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (03) :356-361