Systematic review of clinical applications of monitoring muscle tissue oxygenation with near-infrared spectroscopy in vascular disease

被引:57
作者
Boezeman, Reinout P. E. [1 ]
Moll, Frans L. [2 ]
Unlu, Cagdas [1 ]
de Vries, Jean-Paul P. M. [1 ]
机构
[1] St Antonius Hosp, Dept Vasc Surg, NL-3430 EM Nieuwegein, Netherlands
[2] Univ Med Ctr Utrecht, Dept Vasc Surg, Utrecht, Netherlands
关键词
Spectroscopy; Near-infrared; Vascular diseases; Tissues; Muscles; Peripheral arterial disease; Compartment syndromes; Venous thrombosis; Aortic aneurysm; Abdominal; Free tissue flaps; Spinal cord ischaemia; DEEP-VEIN THROMBOSIS; EXERTIONAL COMPARTMENT SYNDROME; PERIPHERAL ARTERIAL-DISEASE; AORTIC-ANEURYSM REPAIR; PRESSURE MEASUREMENT; INTERMITTENT CLAUDICATION; LIMB ISCHEMIA; SURGERY; DIAGNOSIS; EXERCISE;
D O I
10.1016/j.mvr.2015.11.004
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Background: The use of wavelengths of the near-infrared region by near-infrared spectroscopy (NIRS) has been studied for several applications in vascular disease. This systematic review aims to explore the clinical relevance of monitoring muscle tissue oxygenation in vascular disease with NIRS. Methods: A systematic search in PubMed, EMBASE, CINAHL and Cochrane databases was performed to identify clinical NIRS studies, published until April 2015, involving muscle tissue oxygenation in vascular disease. Results: After screening 183 manuscripts, 38 studies (n = 2010) were included. Studies concerned peripheral arterial disease (PAD) (twelve studies, n = 848), compartment syndrome of lower extremities (seven studies, n = 205), deep vein thrombosis (DVT) (six studies, n = 429), buttock and lower extremity ischaemia in abdominal aortic aneurysm repair (six studies, n = 139), free flap failure (five studies, n = 354), and spinal cord ischaemia in thoracoabdominal aortic aneurysm repair (two studies, n = 35). Nine studies compared NIRS with gold standards and provided cut-off values. Four studies regarding chronic compartment syndrome and DVT determined higher sensitivity (78%-97%) than specificity (56%-76%). Two studies regarding PAD and buttock claudication determined higher specificity (87%-95%) than sensitivity (33%-88%). Three studies regarding free flap failure determined sensitivity and specificity of 100%. Conclusion: We found sufficient evidence to use NIRS in clinical setting for assessment of chronic compartment syndrome of lower extremities, and as surveillance tool for detection of free flap failure. So far, clinical relevance of routine use of NIRS in other vascular applications is less clear. Cut-off values to discriminate are not yet unanimous and better validation has to be awaited for. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:11 / 22
页数:12
相关论文
共 58 条
  • [31] Identification of peripheral vascular disease in elderly subjects using optical spectroscopy
    McCully, KK
    Landsberg, L
    Suarez, M
    Hofmann, M
    Posner, JD
    [J]. JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 1997, 52 (03): : B159 - B165
  • [32] Diffuse optical characterization of an exercising patient group with peripheral artery disease
    Mesquita, Rickson C.
    Putt, Mary
    Chandra, Malavika
    Yu, Guoqiang
    Xing, Xiaoman
    Han, Sung Wan
    Lech, Gwen
    Shang, Yu
    Durduran, Turgut
    Zhou, Chao
    Yodh, Arjun G.
    Mohler, Emile R., III
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [33] Murkin J M, 2009, Br J Anaesth, V103 Suppl 1, pi3, DOI 10.1093/bja/aep299
  • [34] Systematic review of near-infrared spectroscopy determined cerebral oxygenation during non-cardiac surgery
    Nielsen, Henning B.
    [J]. FRONTIERS IN PHYSIOLOGY, 2014, 5
  • [35] The Value of Near-Infrared Spectroscopy Measured Cerebral Oximetry During Carotid Endarterectomy in Perioperative Stroke Prevention. A Review
    Pennekamp, C. W. A.
    Bots, M. L.
    Kappelle, L. J.
    Moll, F. L.
    de Borst, G. J.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 38 (05) : 539 - 545
  • [36] Intramuscular deoxygenation during exercise in patients who have chronic anterior compartment syndrome of the leg
    Randall, L
    Styf, JR
    Pedowitz, RA
    Hargens, AR
    Gershuni, DH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (06) : 844 - 849
  • [37] Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy
    Repez, Andrej
    Oroszy, Dominika
    Arnez, Zoran M.
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2008, 61 (01) : 71 - 77
  • [38] Limb ischemia and reperfusion during abdominal aortic aneurysm surgery
    Sako, H
    Hadama, T
    Miyamoto, S
    Anai, H
    Wada, T
    Iwata, E
    Hamamoto, H
    Tanaka, H
    Morita, M
    [J]. SURGERY TODAY, 2004, 34 (10) : 832 - 836
  • [39] Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications
    Scheeren, T. W. L.
    Schober, P.
    Schwarte, L. A.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2012, 26 (04) : 279 - 287
  • [40] Correlation Between Muscle Oxygenation and Compartment Pressures in Acute Compartment Syndrome of the Leg
    Shuler, Michael S.
    Reisman, William M.
    Kinsey, Tracy L.
    Whitesides, Thomas E., Jr.
    Hammerberg, E. Mark
    Davila, Maria G.
    Moore, Thomas J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (04) : 863 - 870