Fluorimetric determination of aluminium in water by sequential injection through column extraction

被引:21
作者
Brach-Papa, C
Coulomb, B
Branger, C
Margaillan, A
Théraulaz, F
Van Loot, P
Boudenne, JL
机构
[1] Univ Aix Marseille 1, EA 2678, Lab Chim & Environm, F-13331 Marseille 3, France
[2] Univ Toulon & Var, ISITV, MFS EA 1356, Lab Chim Appl, F-83162 La Valette Du Var, France
关键词
aluminium; solid phase extraction; chelating resin; fluorimetry; drinking water;
D O I
10.1007/s00216-003-2464-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fluorimetric procedure for the determination of aluminium with matrix removal in drinking water is proposed. The system is based both on the solid phase extraction of aluminium on a new chelating resin (XAD-4 modified by grafting salicylic acid) and the fluorimetric detection of a complex formed between 8-hydroxyquinoline-5-sulfonic acid (HQS) and Al(III), after elution of the resin by hydrochloric acid. The sorption and elution of aluminium were studied in both competitive and noncompetitive conditions, varying pH, flow-rates, volume and concentration of reagents, as well as time contact. The optimised procedure allows determination of Al3+ at the sub-ppb level (LOD: 0.2 mug L-1 for 1 ml of sample) within a working range of 0.2-500 mug L-1. The analytical procedure was successfully employed for the determination of aluminium in drinking water during and after flocculation/coagulation treatment processes.
引用
收藏
页码:1652 / 1658
页数:7
相关论文
共 45 条
[21]   Interactions between alum and organics in coagulation [J].
Huang, CP ;
Shiu, HL .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 1996, 113 (1-2) :155-163
[22]  
*ISO, 1997, 120201997E ISO
[23]  
*ISO, 1996, 118851996E ISO
[24]   Changes in sample collection and analytical techniques and effects on retrospective comparability of low-level concentrations of trace elements in ground water [J].
Ivahnenko, T ;
Szabo, Z ;
Gibs, J .
WATER RESEARCH, 2001, 35 (15) :3611-3624
[25]   Performance of different preconcentration columns used in sequential injection analysis and inductively coupled plasma-mass spectrometry for multielemental determination in seawater [J].
Jiménez, MS ;
Velarte, R ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (03) :391-402
[26]   DETERMINATION OF ALUMINUM IN NATURAL-WATERS BY SINGLE-COLUMN ION CHROMATOGRAPHY WITH INDIRECT UV DETECTION [J].
LITVINA, ML ;
VOLOSCHIK, IN ;
RUDENKO, BA .
JOURNAL OF CHROMATOGRAPHY A, 1995, 706 (1-2) :307-313
[27]   TRACE ENRICHMENT OF ALUMINUM IONS ON IMMOBILIZED DESFERRIOXAMINE [J].
LJUNGGREN, L ;
ALTRELL, I ;
RISINGER, L ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1992, 256 (01) :75-80
[28]   Spectroscopic study of aluminium speciation in removing humic substances by Al coagulation [J].
Lu, XQ ;
Chen, ZL ;
Yang, XH .
WATER RESEARCH, 1999, 33 (15) :3271-3280
[29]  
MARTINESTEBAN A, ANAL CHIM ACTA, V30, P121
[30]   DETERMINATION OF ALUMINUM AND SILICON IN BIOLOGICAL-MATERIALS BY INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY WITH ELECTROTHERMAL VAPORIZATION [J].
MATUSIEWICZ, H ;
BARNES, RM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1984, 39 (07) :891-899