Fluorimetric determination of aluminium in water by sequential injection through column extraction

被引:21
作者
Brach-Papa, C
Coulomb, B
Branger, C
Margaillan, A
Théraulaz, F
Van Loot, P
Boudenne, JL
机构
[1] Univ Aix Marseille 1, EA 2678, Lab Chim & Environm, F-13331 Marseille 3, France
[2] Univ Toulon & Var, ISITV, MFS EA 1356, Lab Chim Appl, F-83162 La Valette Du Var, France
关键词
aluminium; solid phase extraction; chelating resin; fluorimetry; drinking water;
D O I
10.1007/s00216-003-2464-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fluorimetric procedure for the determination of aluminium with matrix removal in drinking water is proposed. The system is based both on the solid phase extraction of aluminium on a new chelating resin (XAD-4 modified by grafting salicylic acid) and the fluorimetric detection of a complex formed between 8-hydroxyquinoline-5-sulfonic acid (HQS) and Al(III), after elution of the resin by hydrochloric acid. The sorption and elution of aluminium were studied in both competitive and noncompetitive conditions, varying pH, flow-rates, volume and concentration of reagents, as well as time contact. The optimised procedure allows determination of Al3+ at the sub-ppb level (LOD: 0.2 mug L-1 for 1 ml of sample) within a working range of 0.2-500 mug L-1. The analytical procedure was successfully employed for the determination of aluminium in drinking water during and after flocculation/coagulation treatment processes.
引用
收藏
页码:1652 / 1658
页数:7
相关论文
共 45 条
  • [1] Flow-injection solvent extraction with and without phase separation - Fluorimetric determination of aluminium in water
    Alonso, A
    Almendral, MJ
    Porras, MJ
    Curto, Y
    de Maria, CG
    [J]. ANALYTICA CHIMICA ACTA, 2001, 447 (1-2) : 211 - 217
  • [2] [Anonymous], 1997, ALUMINIUM ENV HLTH C
  • [3] Becerra E, 1999, LAB ROBOTICS AUTOMAT, V11, P131, DOI 10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO
  • [4] 2-9
  • [5] Acute aluminum encephalopathy in a dialysis center caused by a cement mortar water distribution pipe
    Berend, K
    van der Voet, G
    Boer, WH
    [J]. KIDNEY INTERNATIONAL, 2001, 59 (02) : 746 - 753
  • [6] Analytical methodologies for aluminium speciation in environmental and biological samples - a review
    Bi, SP
    Yang, XD
    Zhang, FP
    Wang, XL
    Zou, GW
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (08): : 984 - 996
  • [7] On-line separation and spectrophotometric determination of low levels of aluminum in high-salt content samples: application to analysis of hemodialysis fluids
    Bohrer, D
    Gioda, A
    Binotto, R
    do Nascimento, PC
    [J]. ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) : 163 - 169
  • [9] Modification of poly(styrene-co-divinylbenzene) resin by grafting on an aluminium selective ligand
    Boudenne, JL
    Boussetta, S
    Brach-Papa, C
    Branger, C
    Margaillan, A
    Théraulaz, F
    [J]. POLYMER INTERNATIONAL, 2002, 51 (10) : 1050 - 1057
  • [10] Spectrofluorimetric determination of aluminum in drinking waters by sequential injection analysis
    Brach-Papa, C
    Coulomb, B
    Boudenne, JL
    Cerda, V
    Theraulaz, F
    [J]. ANALYTICA CHIMICA ACTA, 2002, 457 (02) : 311 - 318