Determination of gallium and indium by solution cathode glow discharge as an excitation source for atomic emission spectrometry

被引:14
|
作者
Yu, Jie [1 ]
Kang, Yuejing [1 ]
Lu, Quanfang [1 ,2 ]
Luo, Hui [1 ]
Cui, Lijuan [1 ]
Lu, Zhuanhong [1 ]
Li, Juanlong [1 ]
机构
[1] Northwest Normal Univ, Coll Chem & Chem Engn, Key Lab Bioelectrochem & Environm Anal Gansu Prov, Lanzhou 730070, Peoples R China
[2] Northwest Normal Univ, Editorial Dept Univ Journal, Lanzhou 730070, Peoples R China
基金
中国国家自然科学基金;
关键词
Atomic emission spectrometry (AES); Determination; Gallium; Indium; Solution cathode glow discharge (SCGD); DIELECTRIC-BARRIER DISCHARGE; FLOWING ELECTROLYTE-SOLUTIONS; ATMOSPHERIC-PRESSURE; LIQUID CATHODE; WATER SAMPLES; ANALYTICAL PERFORMANCE; RAPID-DETERMINATION; ELEMENTAL ANALYSIS; HEAVY-METALS; ANODE;
D O I
10.1016/j.sab.2020.105968
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In this paper, gallium (Ga) and indium (In) in water samples were determined by atomic emission spectrometry (AES) with solution cathode glow discharge (SCGD) as an excitation source. The optimal working conditions for the detection of Ga and In by proposed method are 660 V discharge voltage, 3.0 mL min(-1) solution flow rate and pH = 1.0 HNO3 as supporting electrolyte. Under these conditions, it is found that there are no obvious inter-ferences from most of the foreign ions when they exist in 20-fold excess over the In. But for Ga, the interferences from foreign ions are severe. The linear correlation coefficient (R-2) is better than 0.99 with a range of 1-40 mu g mL(-1) for Ga and 0.1-30 mu g mL(-1) for In. The limits of detection (LODs) for Ga and In are 0.10 and 0.016 mu g mL(-1), respectively. The relative standard deviations (RSDs) are 2.9% for Ga and 3.9% for In, and the power is below 55 W. To validate the utility and accuracy of the proposed system, two water samples spiked with various concentration (0.3-20 mu g mL(-1)) of Ga and In are directly determined, and the measured results are only in good agreement with spiked values of In. After diluted 10 times for water samples, the spiked values (0.3-20 mu g mL(-1)) of Ga agree well with the measured value, suggesting that the matrix can interfere with the determination of Ga. The satisfactory recoveries between 90% and 109% of In and Ga are achieved.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Ultrasensitive determination of mercury by atmospheric pressure glow discharge optical emission spectroscopy coupled with solution cathode glow discharge microplasma
    Chen, Huixiu
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (10) : 2185 - 2191
  • [12] Ultra-sensitive determination of inorganic arsenic valence by solution cathode glow discharge-atomic emission spectrometry coupled with hydride generation
    Guo, Xiaohong
    Peng, Xiaoxu
    Li, Qing
    Mo, Jiamei
    Du, Yiping
    Wang, Zheng
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (12) : 2416 - 2422
  • [13] Determination of calcium and zinc in gluconates oral solution and blood samples by liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Zhang, Xiaomin
    Lu, Quanfang
    Wang, Xing
    Sun, Duixiong
    Wang, Yongqiang
    Yang, Wu
    TALANTA, 2017, 175 : 150 - 157
  • [14] Rapid determination of indium in water samples using a portable solution cathode glow discharge-atomic emission spectrometer
    Zu, Wenchuan
    Yang, Yin
    Wang, Yu
    Yang, Xiaotao
    Liu, Cong
    Ren, Min
    MICROCHEMICAL JOURNAL, 2018, 137 : 266 - 271
  • [15] Solution Cathode Glow Discharge Atomic Emission Spectrometry in Hydrogen-Helium Atmosphere for On-line Determination of Chromium in Sewage
    Chen, Xiang-YU
    Cai, Zhao-Qing
    Pan, Yu-Bai
    Wang, Zheng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (08) : 1252 - 1259
  • [16] Simultaneously determination of multi metal elements in water samples by liquid cathode glow discharge-atomic emission spectrometry
    Yu, Jie
    Yang, Shuxiu
    Sun, Duixiong
    Lu, Quanfang
    Zheng, Jidong
    Zhang, Xiaomei
    Wang, Xing
    MICROCHEMICAL JOURNAL, 2016, 128 : 325 - 330
  • [17] Highly Sensitive Determination of Cadmium by Atomic Emission Spectrometry with Miniaturized Solution Anode Glow Discharge
    Yu, Jie
    Wang, Xuyi
    Cui, Lijuan
    Hao, Xiaoxia
    Lu, Quanfang
    JOURNAL OF ANALYTICAL CHEMISTRY, 2024, 79 (09) : 1229 - 1241
  • [18] Ultratrace Determination of Tin, Germanium, and Selenium by Hydride Generation Coupled with a Novel Solution-Cathode Glow Discharge-Atomic Emission Spectrometry Method
    Huang, Chuchu
    Li, Qing
    Mo, Jiamei
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2016, 88 (23) : 11559 - 11567
  • [19] Flow Injection Photochemical Vapor Generation Coupled with Miniaturized Solution-Cathode Glow Discharge Atomic Emission Spectrometry for Determination and Speciation Analysis of Mercury
    Mo, Jiamei
    Li, Qing
    Guo, Xiaohong
    Zhang, Guoxia
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10353 - 10360
  • [20] Evaluation of liquid cathode glow discharge-atomic emission spectrometry for determination of copper and lead in ores samples
    Yu, Jie
    Yang, Shuxiu
    Lu, Quanfang
    Sun, Duixiong
    Zheng, Jidong
    Zhang, Xiaomin
    Wang, Xing
    Yang, Wu
    TALANTA, 2017, 164 : 216 - 221