Virtual histology by means of high-resolution X-ray CT

被引:39
作者
Cnudde, V. [1 ]
Masschaele, B. [2 ]
De Cock, H. E. V. [3 ]
Olstad, K. [4 ]
Vlaminck, L. [5 ]
Vlassenbroeck, J. [2 ]
Dierick, M. [2 ]
Witte, Y. D. [2 ]
Van Hoorebeke, L. [2 ]
Jacobs, P. [1 ]
机构
[1] Univ Ghent, Dept Soil Sci & Geol, B-9000 Ghent, Belgium
[2] Univ Ghent, Dept Subatom & Radiat Phys, B-9000 Ghent, Belgium
[3] Univ Antwerp, Dept Vet Med, B-2610 Antwerp, Belgium
[4] Norwegian Sch Vet Sci, Sect Equine Med & Surg, Dept Compan Anim Clin Sci, N-0033 Oslo, Norway
[5] Univ Ghent, Fac Vet Med, Dept Surg & Anaesthesiol Domest Anim, B-9820 Merelbeke, Belgium
关键词
Blood vessels; bone; (dental) alveolus; high-resolution X-ray CT; skin; tarsus; virtual histology;
D O I
10.1111/j.1365-2818.2008.02142.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
Micro-CT is a non-destructive technique for 3D tomographic investigation of an object. A 3D representation of the internal structure is calculated based on a series of X-ray radiographs taken from different angles. The spatial resolution of current laboratory-used micro-CT systems has come down over the last years from a few tens of microns to a few microns. This opens the possibility to perform histological investigations in 3D on a virtual representation of a sample, referred to as virtual 3D histology. The advantage of micro-CT based virtual histology is the immediate and automated 3D visualization of the sample without prior slicing, sample preparation like decalcification, photographing and aligning. This not only permits a drastic reduction in preparation time but also offers the possibility to easily investigate objects that are difficult to slice. This article presents results that were obtained on punch biopsies of horse skin, (dental) alveolus of ponies and chondro-osseous samples from the tarsus of foals studied with the new high resolution micro-CT set-up (HRXCT) at the Ghent University (Belgium) (http://www.ugct.ugent.be). This state-of-the-art set-up provides a 1 micron resolution and is therefore ideally suited for a direct comparison with standard light microscopy-based histology.
引用
收藏
页码:476 / 485
页数:10
相关论文
共 41 条
  • [31] High resolution X-ray computed tomography: An emerging tool for small animal cancer research
    Paulus, MJ
    Gleason, SS
    Kennel, SJ
    Hunsicker, PR
    Johnson, DK
    [J]. NEOPLASIA, 2000, 2 (1-2): : 62 - 70
  • [32] Three-dimensional analysis of root canal geometry by high resolution computed tomography
    Peters, OA
    Laib, A
    Rüegsegger, P
    Barbakow, F
    [J]. JOURNAL OF DENTAL RESEARCH, 2000, 79 (06) : 1405 - 1409
  • [33] Ritman E L, 1998, Technol Health Care, V6, P403
  • [34] Altered myocardial microvascular 3D architecture in experimental hypercholesterolemia
    Rodriguez-Porcel, M
    Lerman, A
    Ritman, EL
    Wilson, SH
    Best, PJM
    Lerman, LO
    [J]. CIRCULATION, 2000, 102 (17) : 2028 - 2030
  • [35] Stereological measures of trabecular bone structure: comparison of 3D micro computed tomography with 2D histological sections in human proximal tibial bone biopsies
    Thomsen, JS
    Laib, A
    Koller, B
    Prohaska, S
    Mosekilde, L
    Gowin, W
    [J]. JOURNAL OF MICROSCOPY, 2005, 218 : 171 - 179
  • [36] ULFENDAHL HR, 1992, KIDNEY PHYSL PATHOPH, P1017
  • [37] Porous gelatin hydrogels: 1. Cryogenic formation and structure analysis
    Van Vlierberghe, Sandra
    Cnudde, Veerle
    Dubruel, Peter
    Masschaele, Bert
    Cosijns, An
    De Paepe, Ilse
    Jacobs, Patric J. S.
    Van Hoorebeke, Luc
    Remon, Jean Paul
    Schacht, Etienne
    [J]. BIOMACROMOLECULES, 2007, 8 (02) : 331 - 337
  • [38] Histologic and micro-computed tomographic evalution of the osseointegration of a nonresorbable bone substitue in alveoli of ponies after tooth extraction
    Vlaminck, Lieven
    Cnudde, Veerle
    Pieters, Koen
    Van Den Broeck, Wim
    Steenhaut, Michel
    Jacobs, Patric
    Gasthuys, Frank
    [J]. AMERICAN JOURNAL OF VETERINARY RESEARCH, 2008, 69 (05) : 604 - 610
  • [39] Software tools for quantification of X-ray microtomography
    Vlassenbroeck, J.
    Dierick, M.
    Masschaele, B.
    Cnudde, V.
    Van Hoorebeke, L.
    Jacobs, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01) : 442 - 445
  • [40] Micro-CT of the human lung: Imaging of alveoli and virtual endoscopy of an alveolar duct in a normal lung and in a lung with centrilobular emphysema - Initial observations
    Watz, H
    Breithecker, A
    Rau, WS
    Kriete, A
    [J]. RADIOLOGY, 2005, 236 (03) : 1053 - 1058