Dual-mode artificially-intelligent diagnosis of breast tumours in shear-wave elastography and B-mode ultrasound using deep polynomial networks

被引:41
作者
Zhang, Qi [1 ,2 ]
Song, Shuang [1 ,2 ]
Xiao, Yang [3 ]
Chen, Shuai [1 ,2 ]
Shi, Jun [1 ]
Zheng, Hairong [3 ]
机构
[1] Shanghai Univ, Shanghai Inst Adv Commun & Data Sci, Room 803,Xiangying Bldg,333 Nanchen Rd, Shanghai 200444, Peoples R China
[2] Shanghai Univ, SMART Smart Med & Al Based Radiol Technol Lab, Inst Biomed Engn, Shanghai 200444, Peoples R China
[3] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Inst Biomed & Hlth Engn, Shenzhen Inst Adv Technol, 1068 Xueyuan Ave, Shenzhen 518055, Peoples R China
基金
美国国家科学基金会;
关键词
Dual-modal diagnosis; Shear-wave elastography; B-mode ultrasound; Breast tumor; Artificial intelligence; Deep polynomial network; ANISOTROPIC DIFFUSION; CLASSIFICATION; CANCER; QUANTIFICATION; IDENTIFICATION; SYSTEM;
D O I
10.1016/j.medengphy.2018.12.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The main goal of this study is to build an artificial intelligence (Al) architecture for automated extraction of dual-modal image features from both shear-wave elastography (SWE) and B-mode ultrasound, and to evaluate the Al architecture for classification between benign and malignant breast tumors. In this Al architecture, ultrasound images were segmented by the reaction diffusion level set model combined with the Gabor-based anisotropic diffusion algorithm. Then morphological features and texture features were extracted from SWE and B-mode ultrasound images at the contourlet domain. Finally, we employed a framework for feature learning and classification with the deep polynomial network (DPN) on dual modal features to distinguish between malignant and benign breast tumors. With the leave-one-out cross validation, the DPN method on dual-modal features achieved a sensitivity of 97.8%, a specificity of 941%, an accuracy of 95.6%, a Youden's index of 91.9% and an area under the receiver operating characteristic curve of 0.961, which was superior to the classic single-modal methods, and the dual-modal methods using the principal component analysis and multiple kernel learning. These results have demonstrated that the dual-modal Al-based technique with DPN has the potential for breast tumor classification in future clinical practice. (C) 2018 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 27 条
  • [21] Muscle B mode ultrasound and shear-wave elastography in idiopathic inflammatory myopathies (SWIM): criterion validation against MRI and muscle biopsy findings in an incident patient cohort
    Shereen Paramalingam
    Merrilee Needham
    Sarah Harris
    Susan O’Hanlon
    Frank Mastaglia
    Helen Keen
    BMC Rheumatology, 6
  • [22] COMPARISON OF STRAIN AND SHEAR WAVE ELASTOGRAPHY FOR THE DIFFERENTIATION OF BENIGN FROM MALIGNANT BREAST LESIONS, COMBINED WITH B-MODE ULTRASONOGRAPHY: QUALITATIVE AND QUANTITATIVE ASSESSMENTS
    Youk, Ji Hyun
    Son, Eun Ju
    Gweon, Hye Mi
    Kim, Hana
    Park, Yun Joo
    Kim, Jeong-Ah
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (10) : 2336 - 2344
  • [23] Binary classification of non-specific low back pain condition based on the combination of B-mode ultrasound and shear wave elastography at multiple sites
    Yu, Xiaocheng
    Xu, Xiaohua
    Huang, Qinghua
    Zhu, Guowen
    Xu, Faying
    Liu, Zhenhua
    Su, Lin
    Zheng, Haiping
    Zhou, Chen
    Chen, Qiuming
    Gao, Fen
    Lin, Mengting
    Yang, Shuai
    Chiang, Mou-Hsun
    Zhou, Yongjin
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [24] Correction to: Muscle B mode ultrasound and shear-wave elastography in idiopathic inflammatory myopathies (SWIM): criterion validation against MRI and muscle biopsy findings in an incident patient cohort
    Paramalingam, Shereen
    Needham, Merrilee
    Harris, Sarah
    O'Hanlon, Susan
    Mastaglia, Frank
    Keen, Helen
    BMC RHEUMATOLOGY, 2022, 6 (01)
  • [25] Evaluation of Postoperative Changes in Patellar and Quadriceps Tendons after Total Knee Arthroplasty-A Comprehensive Analysis by Shear Wave Elastography, Power Doppler and B-mode Ultrasound
    Quack, Valentin
    Betsch, Marcel
    Hellmann, Julian
    Eschweiler, Joerg
    Schrading, Simone
    Gatz, Matthias
    Rath, Bjoern
    Tingart, Markus
    Laubach, Markus
    Kuhl, Christiane K.
    Dirrichs, Timm
    ACADEMIC RADIOLOGY, 2020, 27 (06) : E148 - E157
  • [26] Multimodal feature learning and fusion on B-mode ultrasonography and sonoelastography using point-wise gated deep networks for prostate cancer diagnosis
    Zhang, Qi
    Xiong, Jingyu
    Cai, Yehua
    Shi, Jun
    Xu, Shugong
    Zhang, Bo
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2020, 65 (01): : 87 - 98
  • [27] Automatic Diagnosis of Significant Liver Fibrosis From Ultrasound B-Mode Images Using a Handcrafted-Feature-Assisted Deep Convolutional Neural Network
    Liu, Zhong
    Huang, Bin
    Wen, Huiying
    Lu, Zhicheng
    Huang, Qicai
    Jiang, Meiqin
    Dong, Changfeng
    Liu, Yingxia
    Chen, Xin
    Lin, Haoming
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (10) : 4938 - 4949