The China Spallation Neutron Source (CSNS) is an accelerator-based multidisciplinary user facility. The CSNS facility consists of an 80 MeV H- linear accelerator (1inac), a 1.6 GeV rapid cycling synchrotron (RCS), beam transport lines, a target station, and three sets of instruments with auxiliary equipments. The RCS consists of 24 dipole magnets, 48 quadrupole magnets, 16 sextupole magnets and some corrector magnets. The magnets of the RCS are excited with a repetition frequency of 25 Hz AC bias DC. The magnetic field measurements of the dipole prototype under DC and 25 Hz AC bias DC were carried out at the Institute of High Energy Physics (IHEP). The integral field distribution, harmonic components, transfer function were measured. The measurement results are presented in this paper.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] EDDY CURRENT SIMULATIONS AND MEASUREMENTS OF SODIUM EFFECT FOR MAGNETIC AND NON-MAGNETIC STEAM GENERATOR TUBES OF FBR
    Mihalache, Ovidiu
    Yamaguchi, Toshihiko
    Ueda, Masashi
    Miyahara, Shinya
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 28A AND 28B, 2009, 1096 : 580 - 587
  • [32] Eddy-current-induced magnetic alignment of electroconductive particles under rotating magnetic field
    Kimura, Tsunehisa
    Uemura, Taichi
    Araki, Tomotaka
    Sugitani, Masao
    Kojima, Kazuyuki
    Tsubouchi, Mikihiko
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (06) : 4515 - 4517
  • [33] Controlling induction heating magnetic fields with flux field concentrators
    Learman, Tom
    HEAT TREATING, 2006, : 31 - 38
  • [34] Alternating magnetic field optimization for IONP hyperthermia cancer treatment
    Kastner, Elliot J.
    Reeves, Russell
    Bennett, William
    Misra, Aditi
    Petryk, Jim D.
    Petryk, Alicia A.
    Hoopes, P. Jack
    ENERGY-BASED TREATMENT OF TISSUE AND ASSESSMENT VIII, 2015, 9326
  • [35] Tubular screen in transversal non-uniform magnetic field
    Piatek, Zygmunt
    PRZEGLAD ELEKTROTECHNICZNY, 2009, 85 (06): : 150 - 154
  • [36] Electrical and Calorimetric Power Loss Measurements of Practically Ideal Soft Magnetic Cores
    Zamborszky, Ferenc
    Toth, David
    Palanki, Zoltan
    Csizmadia, Elek
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (04)
  • [37] Magnetic field analysis by edge elements of magnetic components considering inhomogeneous current distribution within conductor windings
    Iwata, K
    Hirano, H
    IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (05) : 1549 - 1554
  • [38] Remote field eddy current control using rotating magnetic field transducer: Application to pressure tubes examination
    Grimberg, Raimond
    Udpa, Lalita
    Savin, Adriana
    Steigmann, Rozina
    Vizureanu, Petrica
    Bruma, Alina
    Udpa, Satish S.
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 2008, 19 (04) : 202 - 218
  • [39] Detection of Sub-pT Field of Magnetic Responses in Metals and Magnetic Materials by Highly Sensitive Magnetoresistive Sensors
    Ahn, Hyuna
    Tanaka, Ayana
    Kono, Yuta
    Trisnanto, Suko Bagus
    Kasajima, Tamon
    Shibuya, Tomohiko
    Takemura, Yasushi
    SENSORS, 2025, 25 (03)
  • [40] Dynamic stability of a cantilever conductive plate in transverse impulsive magnetic field
    Zheng, XJ
    Zhang, JP
    Zhou, YH
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2005, 42 (08) : 2417 - 2430