Two-dimensional magnetotelluric analysis of three-dimensional bodies: a case study from South Australia

被引:0
|
作者
Selway, Kate [1 ]
Heinson, Graham [1 ]
Busuttil, Stephen [2 ]
Lilley, F. E. M. [3 ]
机构
[1] Univ Adelaide, Sch Earth & Environm Sci, Adelaide, SA 5005, Australia
[2] MIM Explorat, Forrestville, SA 5035, Australia
[3] Australian Natl Univ, Res Sch Earth Sci, Canberra, ACT 0200, Australia
关键词
Magnetotellurics; galvanic distortion; dimensionality; inversion;
D O I
10.1071/EG06231
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Magnetotelluric (MT) tensors have significantly different forms depending on whether the subsurface is one-dimensional (ID), two-dimensional (2D), or three-dimensional (3D). In subsurface geological structures that are not ID, two-dimensionality is often assumed, as inversion routines for 2D earth models are computationally more tractable than those for full 3D media. In 2D, the MT tensor decouples into two independent modes, the transverse electric (TE) mode and the transverse magnetic (TM) mode. Often only one of these modes is acquired during commercial operations. Field data were collected over an elongate magnetic anomaly of a type that would normally be approximated as 2D but which has a finite strike length and is therefore a 3D body. With this in mind, the applicability of interpreting data defined as TE and TM were assessed using (a) Mohr circles galvanic distortion analyses, (b) determination of strike of local and regional geology, and (c) comparison of 2D inversion techniques. The data were collected with the Mount Isa Mines Distributed Acquisition System (MIMDAS) in the Deep Well prospect of the Cumamona Province in South Australia. We show that the TM mode accurately delineates boundaries and that since boundary-charges are included in the inversion formulation, it also provides accurate values of apparent resistivity. The TE mode provides poor boundary delineation and underestimates the resistivity of the 3D body. Joint inversions provide only a small improvement upon TM-only inversions, but determination of dimensionality, strike, and detection of galvanic distortion mean that collection of both data modes is still preferable.
引用
收藏
页码:231 / 238
页数:8
相关论文
共 50 条
  • [1] Sensitivity study on two-dimensional and three-dimensional magnetotelluric inversions
    Meng LuTing
    Zhang HuiQian
    Huang QingHua
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2022, 65 (08): : 3078 - 3087
  • [2] Two-dimensional interpretation of three-dimensional magnetotelluric data:: an example of limitations and resolution
    Ledo, J
    Queralt, P
    Martí, A
    Jones, AG
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2002, 150 (01) : 127 - 139
  • [3] A universal three-dimensional instability of the wakes of two-dimensional bluff bodies
    Rao, Anirudh
    Thompson, Mark C.
    Hourigan, Kerry
    JOURNAL OF FLUID MECHANICS, 2016, 792 : 50 - 66
  • [4] Interpretation of two-dimensional magnetotelluric profile data with three-dimensional inversion: synthetic examples
    Siripunvaraporn, W
    Egbert, G
    Uyeshima, M
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2005, 160 (03) : 804 - 814
  • [5] The magnetotelluric anisotropic two-dimensional simulation and case analysis
    Hu Xiang-Yun
    Huo Guang-Pu
    Gao Rui
    Wang Hai-Yan
    Huang Yi-Fan
    Zhang Yun-Xia
    Zuo Bo-Xin
    Cai Jian-Chao
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2013, 56 (12): : 4268 - 4277
  • [6] From two-dimensional to three-dimensional marine spatial planning methodology: A case study of Qidong
    Fang, Jian
    Cheng, Yongxin
    Liu, Baiqiao
    OCEAN & COASTAL MANAGEMENT, 2024, 253
  • [7] From two-dimensional to three-dimensional quantum dots
    Lindemann, S
    Ihn, T
    Heinzel, T
    Ensslin, K
    Maranowski, K
    Gossard, AC
    PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, 2002, 13 (2-4): : 638 - 641
  • [8] Three-dimensional modeling from two-dimensional video
    Aguiar, PMQ
    Moura, JMF
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (10) : 1541 - 1551
  • [9] From two-dimensional to three-dimensional turbulence through two-dimensional three-component flows
    Biferale, L.
    Buzzicotti, M.
    Linkmann, M.
    PHYSICS OF FLUIDS, 2017, 29 (11)
  • [10] Are Three-Dimensional Monitors More Appropriate Than Two-Dimensional Monitors in the Three-Dimensional Analysis?
    Ahn, Jaemyung
    Hong, Jongrak
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (01) : E101 - E104