Electromagnetic tracking for US-guided interventions: standardized assessment of a new compact field generator

被引:20
作者
Franz, A. M. [1 ]
Maerz, K. [1 ]
Hummel, J. [2 ]
Birkfellner, W. [2 ]
Bendl, R. [1 ]
Delorme, S. [1 ]
Schlemmer, H. -P. [1 ]
Meinzer, H. -P. [1 ]
Maier-Hein, L. [1 ]
机构
[1] German Canc Res Ctr, D-69120 Heidelberg, Germany
[2] Med Univ Vienna, Christian Doppler Lab Med Radiat Res Radiat Oncol, A-1090 Vienna, Austria
关键词
Electromagnetic tracking; Electromagnetic field generator; Compact field generator; Tracked ultrasound; Computer-assisted interventions; Ultrasound-guided interventions; 3D ULTRASOUND PROBES; NAVIGATION; SYSTEMS;
D O I
10.1007/s11548-012-0740-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose One of the main challenges related to electromagnetic tracking in the clinical setting is a placement of the field generator (FG) that optimizes the reliability and accuracy of sensor localization. Recently, a new mobile FG for the NDI Aurora (R) tracking system has been presented. This Compact FG is the first FG that can be attached directly to an ultrasound (US) probe. The purpose of this study was to assess the precision and accuracy of the Compact FG in the presence of nearby mounted US probes. Materials and methods Six different US probes were mounted onto the Compact FG by means of a custom-designed mounting adapter. To assess precision and accuracy of the Compact FG, we employed a standardized assessment protocol. Utilizing a specifically manufactured plate, we measured positional data on three levels of distances from the FG as well as rotational data. Results While some probes had negligible influence on tracking accuracy two probes increased the mean distance error up to 1.5 mm compared with a reference measurement of 0.5 mm. The jitter error consistently stayed below 0.2 mm in all cases. The mean relative error in orientation was found to be smaller than 3 degrees. Conclusion Attachment of an US probe to the Compact FG does not have a critical influence on tracking accuracy in most cases. Clinical benefit of this promising mobile FG must be shown in future studies.
引用
收藏
页码:813 / 818
页数:6
相关论文
共 11 条
  • [1] Precision targeting of liver lesions using a novel electromagnetic navigation device in physiologic phantom and swine
    Banovac, F
    Tang, J
    Xu, S
    Lindisch, D
    Chung, HY
    Levy, EB
    Chang, T
    McCullough, MF
    Yaniv, Z
    Wood, BJ
    Cleary, K
    [J]. MEDICAL PHYSICS, 2005, 32 (08) : 2698 - 2705
  • [2] Comparing calibration approaches for 3D ultrasound probes
    Bergmeir, C.
    Seitel, M.
    Frank, C.
    De Simone, R.
    Meinzer, H. -P.
    Wolf, I.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (02) : 203 - 213
  • [3] Birkfellner W., 2008, IMAGE GUIDED INTERVE
  • [4] Ultrasound-guided interventions using magnetic field navigation.: First experiences with ultra-guide 2000™ under operative conditions
    Birth, M
    Iblher, P
    Hildebrand, P
    Nolde, J
    Bruch, HP
    [J]. ULTRASCHALL IN DER MEDIZIN, 2003, 24 (02): : 90 - 95
  • [5] Ultrasound self-calibration
    Boctor, Emad M.
    Iordachita, Lulian
    Fichtinger, Gabor
    Hager, Gregory D.
    [J]. MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [6] ULTRASOUND IN MEDICINE - REVIEW
    ERIKSON, KR
    FRY, FJ
    JONES, JP
    [J]. IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1974, SU21 (03): : 144 - 170
  • [7] Effect of 3D ultrasound probes on the accuracy of electromagnetic tracking systems
    Hastenteufel, Mark
    Vetter, Marcus
    Meinzer, Hans-Peter
    Wolf, Ivo
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2006, 32 (09) : 1359 - 1368
  • [8] Design and application of an assessment protocol for electromagnetic tracking systems
    Hummel, JB
    Bax, MR
    Figl, ML
    Kang, Y
    Maurer, C
    Birkfellner, WW
    Bergmann, H
    Shahidi, R
    [J]. MEDICAL PHYSICS, 2005, 32 (07) : 2371 - 2379
  • [9] Maier-Hein L, 2012, MED PHYS IN PRESS
  • [10] Image-guidance for surgical procedures
    Peters, Terry M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (14) : R505 - R540