Comparison of three methods of measuring corneal thickness and anterior chamber depth

被引:207
作者
Buehl, W
Stojanac, D
Sacu, S
Drexler, W
Findl, O
机构
[1] Med Univ Vienna, Dept Ophthalmol, A-1090 Vienna, Austria
[2] Med Univ Vienna, Dept Med Phys, Vienna, Austria
关键词
D O I
10.1016/j.ajo.2005.08.048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare three different methods of measuring corneal thickness (CT) and anterior chamber depth (ACD). DESIGN: Prospective clinical trial (Medical University of Vienna, Austria). METHODS: Central CT (CCT), CT at four peripheral points, and central ACD were measured in 88 eyes of 44 healthy subjects with the Pentacam (rotating Scheimpflug camera; Oculus, Wetzlar, Germany), Orbscan I (scanning-slit topography system; Orbtek Inc, Salt Lake City, Utah, USA), and AC-Master (partial coherence interferome try; Zeiss Meditec, Jena, Germany), and the results were compared. RESULTS: The upper (lower) limits of agreement for CT measurements were 7.9 (-22.2) mu m between AC- Master and Pentacam, 17.6 (-32.5) mu m between AC- Master and Orbscan, and 25.2 (-25.9) mu m between Pentacam and Orbscan. Correlation was high between all three methods (r = 0.94 to 0.97). The upper and lower limits of agreement for ACD were 0.174 (-0.251) mm between AC-Master and Pentacam, 0.406 (-0.004) mm between AC-Master and Orbscan, and 0.384 (0.095) mm between Pentacam and Orbscan. Correlation was high between the three methods (r = 0.96 between Orbscan and Pentacam; others 0.92). Correlation was lower for the CT measurements at the four peripheral points. CONCLUSIONS: The CCT and ACD values obtained by Pentacam, Orbscan, and AC-Master measurements correlated well and showed few outliers. The two new systems (Pentacam, AC,Master) provide a reliable, easy-to-use, noncontact method of measuring CCT and ACD. Larger differences occurred only when measuring peripheral CT values, especially between AC,Master and the other two methods.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 20 条
  • [1] Measuring agreement in method comparison studies
    Bland, JM
    Altman, DG
    [J]. STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) : 135 - 160
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Drexler W, 1997, INVEST OPHTH VIS SCI, V38, P1304
  • [4] Partial coherence interferometry: A novel approach to biometry in cataract surgery
    Drexler, W
    Findl, O
    Menapace, R
    Rainer, G
    Vass, C
    Hitzenberger, CK
    Fercher, AF
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) : 524 - 534
  • [5] High precision biometry of pseudophakic eyes using partial coherence interferometry
    Findl, O
    Drexler, W
    Menapace, R
    Hitzenberger, CK
    Fercher, AF
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (08) : 1087 - 1093
  • [6] HITZENBERGER CK, 1991, INVEST OPHTH VIS SCI, V32, P616
  • [7] Anterior chamber depth estimation by Scheimpflug photography
    Holmén, JB
    Ekesten, B
    Lundgren, B
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2001, 79 (06): : 576 - 579
  • [8] Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis
    Kawana, K
    Tokunaga, T
    Miyata, K
    Okamoto, F
    Kiuchi, T
    Oshika, T
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (04) : 466 - 468
  • [9] Anterior chamber depth measurement: A-scan versus optical methods
    Koranyi, G
    Lydahl, E
    Norrby, S
    Taube, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) : 243 - 247
  • [10] The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster™
    Lam, AKC
    Chan, R
    Pang, PCK
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2001, 21 (06) : 477 - 483