摘要
To evaluate cardiovascular risks at an early stage, the pulse wave velocity (PWV) is a relevant marker that reflects stiffening and ageing of the arterial network. Today, several gold standard methods exist to measure PWV, in particular regional PWV, but they are only available in clinical environments. Moreover, they are mainly used for one-time measurements and are potentially biased. However, PWV can also be locally assessed to target specific arteries by the mean of ultrasonic devices using pulse transit time (PTT) or flow-section (QA) based methods. In this study, we aim to demonstrate a full Doppler QA method to measure the PWV at the ulnar artery using a high-frequency (HF) ultrasonic probe that could lay the basis for a wrist-worn device dedicated to cardiovascular risk assessment. By using a custom high-frequency H-probe and a Vantage system, PWVs from 6 to 14 m/s from a 1-hour experiment with a median value of 8.25 m/s have been measured at the ulnar artery of a healthy volunteer. These results agree with literature and expected values for small arteries, typically ulnar or radial arteries.
引用
收藏
页数:5
相关论文
共 28 条
[2]   Arterial blood pressure measurement and pulse wave analysis-their role in enhancing cardiovascular assessment [J].
Avolio, Alberto P. ;
Butlin, Mark ;
Walsh, Andrew .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (01) :R1-R47
[3]   A high-frequency linear probe with H-topology for PWV measurements on superficial arteries [J].
Benchemoul, Maxime ;
Lejeune, Agnes ;
Porcher, Nicolas ;
Montauban, Emmanuel ;
Ferin, Guillaume ;
Gehin, Claudine ;
Massot, Bertrand ;
Vince, Philippe ;
Flesch, Martin .
INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
[4]   Pulse wave velocity measurement along the ulnar artery in the wrist region using a high frequency ultrasonic array [J].
Benchemoul, Maxime ;
Mateo, Tony ;
Savery, David ;
Gehin, Claudine ;
Massot, Bertrand ;
Ferin, Guillaume ;
Vince, Philippe ;
Flesch, Martin .
2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, :4123-4127
[5]  
Berger David S., 1994, American Journal of Physiology, V266, pH1626
[7]  
Butlin M., 2015, MECH PROPERTIES AGIN, P37, DOI [10.1007/978-3-319-03970-1_3, DOI 10.1007/978-3-319-03970-1_3]
[8]   Non-Invasive Methods for PWV Measurement in Blood Vessel Stiffness Assessment [J].
Fiori, Giorgia ;
Fuiano, Fabio ;
Scorza, Andrea ;
Conforto, Silvia ;
Sciuto, Salvatore Andrea .
IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2022, 15 :169-183
[9]   Robust smoothing of gridded data in one and higher dimensions with missing values [J].
Garcia, Damien .
COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2010, 54 (04) :1167-1178
[10]   Estimation of blood velocity, volumetric flow and wall shear rate using Doppler ultrasound [J].
Hoskins, Peter R. .
ULTRASOUND, 2011, 19 (03) :120-129