The influence of the cementation margin position on the amount of undetected cement. A prospective clinical study

被引:165
作者
Linkevicius, Tomas [1 ,2 ,3 ]
Vindasiute, Egle [2 ,3 ]
Puisys, Algirdas [2 ,3 ]
Linkeviciene, Laura [1 ]
Maslova, Natalja [3 ]
Puriene, Alina [1 ]
机构
[1] Vilnius State Univ, Fac Med, Inst Odontol, LT-08217 Vilnius, Lithuania
[2] Vilnius Res Grp, Vilnius, Lithuania
[3] Vilnius Implantol Ctr, Vilnius, Lithuania
关键词
cement cleaning; cement excess; cement-related peri-implantitis; cement-retained implant restorations; subgingival margins; OSSEOINTEGRATED IMPLANTS; BIOLOGIC WIDTH; EXCESS CEMENT; TITANIUM; RESTORATIONS; PROGNOSIS; ABUTMENTS; REMOVAL; CROWNS; FIT;
D O I
10.1111/j.1600-0501.2012.02453.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To evaluate the amount of undetected cement after cementation and cleaning of implant-supported restorations. Materials and methods Fifty three patients were treated with 53 single implant-supported metal-ceramic restorations. The subgingival location of the margin of each implant was measured with a periodontal probe mesially, distally, buccaly, and lingually, resulting in 212 measurements. The data were divided into four groups: equally with tissue level (14 samples), 1 mm subgingivally (56), 2 mm (74), and 3 mm (68) below tissues contour. Metal-ceramic restorations were fabricated with occlusal openings and cemented on standard abutments with resin-reinforced glass-ionomer. After cleaning, a radiograph was taken to assess if all cement had been removed. Then the abutment/crown unit was unscrewed for evaluation. All quadrants of the specimens and peri-implant tissues were photographed and analyzed with Adobe Photoshop. Two proportions were calculated: (1) the relation between the cement remnants area and the total area of the abutment/restoration and (2) the relation between the cement remnants and the total area of implant soft tissue contour. Significance set to 0.05. Results Excess on the crown groups: 1 (0.002 +/- 0.001); 2 (0.024 +/- 0.005); 3 (0.036 +/- 0.004); 4 (0.055 +/- 0.007). Undetected excess increased when the margin was located deeper subgingivally (P = 0.000), significant difference was found among all groups (P = 0.05). Remnants in the soft tissue groups: 1 (0.014 +/- 0.006); 2 (0.052 +/- 0.011); 3 (0.057 +/- 0.009); 4 (0.071 +/- 0.012). The increase of the remnants was statistically reliable (P = 0.0045), significant difference was found between group 1 and 2 (P = 0.05). Radiographic evaluation showed that cement remnants mesially were visible in four cases of 53 or 7.5%, and in six cases of 53 distally (11.3%). Conclusions The deeper the position of the margin, the greater amount of undetected cement was discovered. Dental radiographs should not be considered as a reliable method for cement excess evaluation.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 27 条
[1]   Cement removal from restorations luted to titanium abutments with simulated subgingival margins [J].
Agar, JR ;
Cameron, SM ;
Hughbanks, JC ;
Parker, MH .
JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (01) :43-47
[2]  
Aleksejuniene J, 2006, Int J Dent Hyg, V4, P35
[3]  
Andersson B, 1998, INT J PROSTHODONT, V11, P212
[4]   A 10-year prospective study of ITI dental implants placed in the posterior region. II: Influence of the crown-to-implant ratio and different prosthetic treatment modalities on crestal bone loss [J].
Blanes, Rafael Juan ;
Bernard, Jean Pierre ;
Blanes, Zulema Maria ;
Belser, Urs Christoph .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (06) :707-714
[5]   MARGINAL FIT OF GOLD INLAY CASTINGS [J].
CHRISTENSEN, GJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1966, 16 (02) :297-+
[6]   Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible [J].
Cochran, DL ;
Hermann, JS ;
Schenk, RK ;
Higginbottom, FL ;
Buser, D .
JOURNAL OF PERIODONTOLOGY, 1997, 68 (02) :186-197
[7]   Techniques to minimize excess luting agent in cement-retained implant restorations [J].
Dumbrigue, HB ;
Abanomi, AA ;
Cheng, LL .
JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (01) :112-114
[8]   PROBING DEPTH AT IMPLANTS AND TEETH - AN EXPERIMENTAL-STUDY IN THE DOG [J].
ERICSSON, I ;
LINDHE, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1993, 20 (09) :623-627
[9]  
Gapski R, 2008, INT J ORAL MAX IMPL, V23, P943
[10]   Impact of IL-1 genotype and smoking status on the prognosis of osseointegrated implants [J].
Gruica, B ;
Wang, HY ;
Lang, NP ;
Buser, D .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :393-400