Development of an HPLC/diode-array detector method for simultaneous determination of seven hydroxycinnamic acids in green coffee

被引:13
|
作者
Andrade, PB [1 ]
Leitao, R [1 ]
Seabra, RM [1 ]
Oliveira, MB [1 ]
Ferreira, MA [1 ]
机构
[1] UNIV PORTO, FAC FARM, LAB BROMATOL, P-4050 OPORTO, PORTUGAL
关键词
D O I
10.1080/10826079708005561
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, rapid, sensitive, reproducible, and accurate reverse phase HPLC procedure is proposed for the determination of seven phenolic acids in green coffee samples. The sample preparation was simple, involving extraction, alkaline hydrolysis, and liquid/liquid extraction. The chromatographic separation was achieved using a reverse phase column Spherisorb ODS2 (5 mu m; 25.0 x 0.46 cm). Gradient elution was carried out using water-formic acid (19:1) (A) and methanol (B). The effluent was monitored by a diode-array detector and chromatograms were recorded at 320 nm. The detection limit value of the method was 0.09 mu g/mL and the method was precise (CV% = 0.5%; n = 10). Recovery values of caffeic acid from spiked green coffee samples were between 88.3 and 93.2%.
引用
收藏
页码:2023 / 2030
页数:8
相关论文
共 50 条
  • [21] MULTIRESIDUE ANALYSIS OF PHENYLUREA HERBICIDES IN CROPS BY HPLC WITH DIODE-ARRAY DETECTOR
    LAGANA, A
    MARINO, A
    FAGO, G
    MARTINEZ, BP
    ANALUSIS, 1994, 22 (02) : 63 - 69
  • [22] Determination of gatifloxacin in semen by HPLC with diode-array and fluorescence detection
    Salazar-Cavazos, M. L.
    Gonzalez, L. Y. Colunga
    de Lerma, G. Gallegos
    de Torres, N. Waksman
    CHROMATOGRAPHIA, 2006, 63 (11-12) : 605 - 608
  • [23] Determination of Gatifloxacin in Semen by HPLC with Diode-Array and Fluorescence Detection
    M. L. Salazar Cavazos
    L. Y. Colunga González
    G. Gallegos de Lerma
    N. Waksman de Torres
    Chromatographia, 2006, 63 : 605 - 608
  • [24] Development and optimization of the determination of pharmaceuticals in water samples by SPE and HPLC with diode-array detection
    Pavlovic, Dragana Mutavdzic
    Asperger, Danijela
    Tolic, Dijana
    Babic, Sandra
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (18) : 3042 - 3049
  • [25] Determination of furosine in hydrolyzate of processed milk by HPLC using a narrow bore column and diode-array detector
    Nicoletti, I
    Cogliandro, E
    Corradini, C
    Corradini, D
    Pizzoferrato, L
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (05) : 717 - 726
  • [26] POTENTIALS OF HPLC WITH A MULTICHANNEL DIODE-ARRAY SPECTROPHOTOMETRIC DETECTOR IN SYSTEMATIC TOXICOLOGICAL ANALYSIS
    DEZEEUW, RA
    FRANKE, JP
    BOGUSZ, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 76 - ANYL
  • [27] Rapid and sensitive HPLC method for the simultaneous determination of dorzolamide hydrochloride and timolol maleate in eye drops with diode-array and UV detection
    Erk, N
    PHARMAZIE, 2003, 58 (07): : 491 - 493
  • [28] IDENTIFICATION OF PHYTOPLANKTON PIGMENTS BY RP-HPLC WITH DIODE-ARRAY TYPE DETECTOR
    KOWALEWSKA, G
    CHEMIA ANALITYCZNA, 1993, 38 (06): : 711 - 718
  • [29] HPLC/diode-array applied to the thermal degradation of trigonelline, nicotinic acid and caffeine in coffee
    Casal, S
    Oliveira, MB
    Ferreira, MA
    FOOD CHEMISTRY, 2000, 68 (04) : 481 - 485
  • [30] Determination of free and total phenolic acids in plant-derived foods by HPLC with diode-array detection
    Mattila, P
    Kumpulainen, J
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (13) : 3660 - 3667