Sonographically assisted percutaneous release of the A1 pulley: A new surgical technique for treating trigger digit

被引:67
作者
Jou, IM
Chern, TC
机构
[1] Natl Cheng Kung Univ, Coll Med, Dept Orthopaed, Tainan 70428, Taiwan
[2] Pingtong Christian Hosp, Dept Orthopaed Surg, Pingtong, Taiwan
关键词
percutaneous release; trigger digit; sonognaphy;
D O I
10.1016/j.jhsb.2005.11.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study introduces a sonographically assisted percutaneous technique for releasing trigger digits which provides direct visualization of the release and avoids the risks of incomplete release and injury to adjacent neurovascular structures associated with other percutaneous release techniques. The "safe zone" and an estimate of the size of the A1 pulley were determined in a separate cadaver study. We then used these landmarks in a prospective clinical study of 107 digits in 83 consecutive patients treated by this technique. During the follow-ups of between 9 and 15 months, we evaluated 104 digits in 80 patients. Pain was absent in 101 digits (97%) and considerably improved in the other three (3%). All mechanical problems had been resolved and none recurred during follow-up. This technique allows the surgeon to see and monitor, precisely, the percutaneous division of the A I pulley without open surgery and, therefore, to avoid the inherent risks of percutaneous and open surgical release.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 33 条
[21]   ULTRASOUND FOR CLOSED FEMORAL NAILING [J].
MAHAISAVARIYA, B ;
SUIBNUGARN, C ;
MAIRIANG, E ;
SAENGNIPANTHKUL, S ;
LAUPATTARAKASEM, W ;
KOSUWON, W .
JOURNAL OF CLINICAL ULTRASOUND, 1991, 19 (07) :393-397
[22]   TRIGGER DIGIT - THE NEEDLE OR THE KNIFE [J].
PANAYOTOPOULOS, E ;
FORTIS, AP ;
ARMONI, A ;
DIMAKOPOULOS, P ;
LAMBIRIS, E .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1992, 17B (02) :239-240
[23]   Percutaneous release of trigger digit with and without cortisone injection [J].
Patel, MR ;
Moradia, VJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (01) :150-155
[24]   TRIGGER FINGERS AND THUMB - WHEN TO SPLINT, INJECT, OR OPERATE [J].
PATEL, MR ;
BASSINI, L .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (01) :110-113
[25]   SAFETY AND EFFICACY OF PERCUTANEOUS TRIGGER FINGER RELEASE [J].
POPE, DF ;
WOLFE, SW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (02) :280-283
[26]   THE USE OF ULTRASOUND DURING SPINAL-CORD SURGERY [J].
RUBIN, JM ;
CHANDLER, WF .
WORLD JOURNAL OF SURGERY, 1987, 11 (05) :570-578
[27]  
Saldana M J, 2001, J Am Acad Orthop Surg, V9, P246
[28]  
Stothard J, 1994, J R Coll Surg Edinb, V39, P116
[29]   SUBCUTANEOUS RELEASE OF TRIGGER THUMB AND FINGERS IN 210 FINGERS [J].
TANAKA, J ;
MURAJI, M ;
NEGORO, H ;
YAMASHITA, H ;
NAKANO, T ;
NAKANO, K .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1990, 15B (04) :463-465
[30]   RESULTS OF SURGERY FOR TRIGGER FINGER [J].
THORPE, AP .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1988, 13B (02) :199-201