Development of a direct current power system for a multi-node cabled ocean observatory system

被引:25
作者
Chen, Yan-hu [1 ]
Yang, Can-jun [1 ]
Li, De-jun [1 ]
Jin, Bo [1 ]
Chen, Ying [1 ]
机构
[1] Zhejiang Univ, State Key Lab Fluid Power Transmiss & Control, Hangzhou 310027, Peoples R China
来源
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE C-COMPUTERS & ELECTRONICS | 2012年 / 13卷 / 08期
关键词
Cabled ocean observatory system; DC power system; Heat dissipation; Deep sea; ACTIVE INPUT-VOLTAGE; DC-DC CONVERTERS; SERIES;
D O I
10.1631/jzus.C1100381
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Due to the shortage of suitable research methods for real-time and long-term observation of oceans, an innovative approach that can provide abundant power and wide bandwidth is being developed worldwide for undersea instruments. In this paper, we develop a direct current (DC) power system which is applied to a multi-node cabled ocean observatory system named ZERO (Zhejiang University Experimental and Research Observatory). The system addresses significant issues ranging from terrestrial facility to subsea infrastructure, and focuses on using appropriate methods to deal with several key challenges, including delivery, conversion, distribution, and management of power, and heat dissipation in pressure vessels. A basic laboratory platform consisting of a shore station, a primary node in a water tank, and a secondary node in a deep-sea simulation chamber under 42 MPa pressure was built and fully tested. An improved secondary node was deployed in Monterey Bay in California for a deep-sea trial. An 11-day laboratory test and a half-year sea trial proved that the DC power system based on our proposed methods is viable for the underwater multi-node observatory system.
引用
收藏
页码:613 / 623
页数:11
相关论文
共 27 条
[1]   Automated Image Analysis for the Detection of Benthic Crustaceans and Bacterial Mat Coverage Using the VENUS Undersea Cabled Network [J].
Aguzzi, Jacopo ;
Costa, Corrado ;
Robert, Katleen ;
Matabos, Marjolaine ;
Antonucci, Francesca ;
Juniper, S. Kim ;
Menesatti, Paolo .
SENSORS, 2011, 11 (11) :10534-10556
[2]   The New Seafloor Observatory (OBSEA) for Remote and Long-Term Coastal Ecosystem Monitoring [J].
Aguzzi, Jacopo ;
Manuel, Antoni ;
Condal, Fernando ;
Guillen, Jorge ;
Nogueras, Marc ;
del Rio, Joaquin ;
Costa, Corrado ;
Menesatti, Paolo ;
Puig, Pere ;
Sarda, Francesc ;
Toma, Daniel ;
Palanques, Albert .
SENSORS, 2011, 11 (06) :5850-5872
[3]   A network-based telemetry architecture developed for the Martha's Vineyard Coastal Observatory [J].
Austin, TC ;
Edson, JB ;
McGillis, WR ;
Purcell, M ;
Petitt, RA ;
McElroy, MK ;
Grant, CW ;
Ware, J ;
Hurst, SK .
IEEE JOURNAL OF OCEANIC ENGINEERING, 2002, 27 (02) :228-234
[4]   Active input-voltage and load-current sharing in input-series and output-parallel connected modular DC-DC converters using dynamic input-voltage reference scheme [J].
Ayyanar, R ;
Giri, R ;
Mohan, N .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (06) :1462-1473
[5]   The NEPTUNE Project - a cabled ocean observatory in the NE Pacific: Overview, challenges and scientific objectives for the installation and operation of Stage I in Canadian waters [J].
Barnes, C. R. ;
Best, M. M. R. ;
Bornhold, B. A. ;
Juniper, S. K. ;
Pirenne, B. ;
Phibbs, P. .
2007 SYMPOSIUM ON UNDERWATER TECHNOLOGY AND WORKSHOP ON SCIENTIFIC USE OF SUBMARINE CABLES AND RELATED TECHNOLOGIES, VOLS 1 AND 2, 2007, :308-+
[6]  
Barnes CR, 2008, OCEANS-IEEE, P1021
[7]  
Bhinge A, 2002, APPL POWER ELECT CO, P648, DOI 10.1109/APEC.2002.989314
[8]   Cabled ocean observatory systems [J].
Chave, AD ;
Waterworth, G ;
Maffei, AR ;
Massion, G .
MARINE TECHNOLOGY SOCIETY JOURNAL, 2004, 38 (02) :30-43
[9]   A Input-Series- and Output-Parallel-Connected Inverter System for High-Input-Voltage Applications [J].
Chen, Wu ;
Zhuang, Kai ;
Ruan, Xinbo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (09) :2127-2137
[10]  
Clark AM, 2001, OCEANS 2001 MTS/IEEE: AN OCEAN ODYSSEY, VOLS 1-4, CONFERENCE PROCEEDINGS, P1290, DOI 10.1109/OCEANS.2001.968296