Management of systemic unfractionated heparin anticoagulation during therapeutic plasma exchange

被引:23
作者
Kaplan, Alesia [1 ]
Raut, Prachi [1 ]
Totoe, Grace [2 ]
Morgan, Shanna [1 ,3 ,4 ]
Zantek, Nicole D. [1 ]
机构
[1] Univ Minnesota, Dept Lab Med & Pathol, 420 Delaware St SE,MMC 609, Minneapolis, MN 55455 USA
[2] North Mem Med Ctr, Dept Hosp Med, Acute Care Med, Robbinsdale, MN USA
[3] North Cent Blood Serv, Amer Red Cross, St Paul, MN USA
[4] Vet Affairs Med Ctr, Minneapolis, MN USA
关键词
plasmapheresis; plasma exchange; heparin; coagulation; catastrophic antiphospholipid syndrome; COAGULATION PARAMETERS; CELL SEPARATOR; PLASMAPHERESIS; REMOVAL; COMPLICATIONS; MEDICATIONS; APHERESIS; RECOVERY;
D O I
10.1002/jca.21441
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background:Therapeutic plasma exchange (TPE) may remove medications from the patient's plasma. Data is limited on the effect of TPE on unfractionated heparin (UFH). Study Design and Methods: A retrospective review was performed of patients receiving TPE and continuous IV infusion UFH from 1/1/2008 to 6/30/2010. TPE with plasma or 5% albumin for replacement fluid and pre and post anti-Xa levels within approximately six hours were analyzed. Results: Three patients had 15 TPE with plasma replacement. Anti-Xa levels decreased 47% (mean, -0.25 IU/mL) for two TPE when UFH was not changed, 78% (-0.35 IU/mL) for one TPE when the UFH rate was decreased 25%; and 61% (mean -0.72 IU/mL) for two single volume TPE and 87% (-0.65 IU/mL) for one 1.5 plasma volume TPE when UFH was stopped. During nine TPE, the UFH rate was increased by 65% resulting in a mean increase in the anti-Xa level (mean 0.06 IU/mL, 30%). One patient had five single plasma volume TPE with 5% albumin. Anti-Xa levels decreased when the UFH was not changed (-0.06 IU/mL, 38%) and increased when UFH was increased by 30% (0.19 IU/mL, 61%) and 69% (mean 0.04 IU/mL, 15% in three TPE). The PTT increased with all albumin procedures, with more marked increases observed when the UFH rate was increased, while the antithrombin level decreased (mean 65%). Conclusion: Heparin was removed from the patient's plasma during TPE. Adjustment of the dose during TPE may be necessary to maintain therapeutic drug levels. Methods for monitoring UFH therapy may not agree. J. Clin. Apheresis 31:507-515, 2016. (c) 2016 Wiley Periodicals, Inc.
引用
收藏
页码:507 / 515
页数:9
相关论文
共 35 条
  • [1] Alquwaizani M, 2013, CURR EMERG HOSP ME R, V1, P83, DOI 10.1007/s40138-013-0014-6
  • [2] CHIRNSIDE A, 1981, BRIT J HAEMATOL, V48, P627
  • [3] Chopek M, 1980, THERAPEUTIC HEMAPHER, P13
  • [4] Efficacy and safety of plasma exchange: ann 11-year single-center experience of 2730 procedures in 317 patients
    Cid, Joan
    Carbasse, Gloria
    Andreu, Bienvenida
    Baltanas, Antonio
    Garcia-Carulla, Ana
    Lozano, Miguel
    [J]. TRANSFUSION AND APHERESIS SCIENCE, 2014, 51 (02) : 209 - 214
  • [5] COMPLICATIONS OF THERAPEUTIC PLASMA-EXCHANGE - A RECENT ASSESSMENT
    COURIEL, D
    WEINSTEIN, R
    [J]. JOURNAL OF CLINICAL APHERESIS, 1994, 9 (01) : 1 - 5
  • [6] DESWART CAM, 1982, BLOOD, V60, P1251
  • [7] HEMOSTATIC IMBALANCES PRODUCED BY PLASMA-EXCHANGE
    DOMEN, RE
    KENNEDY, MS
    JONES, LL
    SENHAUSER, DA
    [J]. TRANSFUSION, 1984, 24 (04) : 336 - 339
  • [8] ESTES JW, 1975, CURR THER RES CLIN E, V18, P45
  • [9] ESTES JW, 1969, CLIN PHARMACOL THER, V10, P329
  • [10] FLAUM MA, 1979, BLOOD, V54, P694