Evaporative pad cooling model validation in a closed dairy cattle building

被引:11
作者
Obando, Felipe A. [1 ]
Montoya, Ana P. [1 ]
Osorio, Jairo A. [1 ]
Damasceno, Flavio A. [2 ]
Norton, Tomas [3 ]
机构
[1] Univ Nacl Colombia, Fac Ciencias Agr, Medellin, Antioquia, Colombia
[2] Univ Fed Lavras, Dept Engn, Lavras, MG, Brazil
[3] Katholieke Univ Leuven, Div Measure Model & Manage Bioresponses M3 Biores, Kasteelpk Arenberg 30, B-3001 Leuven, Belgium
关键词
Cellulose pad cooling; Heat and mass transfer coefficients; Evaporative pad cooling model; Direct evaporative cooling; Closed dairy cattle building; MASS-TRANSFER; PERFORMANCE; SYSTEM;
D O I
10.1016/j.biosystemseng.2020.08.005
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A mathematical model of an evaporative pad cooling system to predict the dry-bulb temperature and relative humidity of air exiting the pad, its cooling efficiency and the water requirements for agricultural buildings was derived from first principles using mass and energy balances. The model uses the geometry of the evaporative pad as characteristic parameters and the water temperature, dry-bulb temperature and relative humidity of the outside air as primary boundary conditions. The model was validated with data from wind tunnel tests and field experiments on a closed dairy cattle building using an evaporative pad cooling system. These data also enabled new expressions for heat and mass transfer coefficients of a cellulose cooling pad to be developed and validated. The resulting model accurately predicted the main output variables in the closed dairy cattle building, with the prediction error falling inside the accuracy of the sensors used to measure the environmental variables (+/- 0.5 degrees C and +/- 3% for dry-bulb temperature and relative humidity, respectively). The effect of pad water temperature on the output variables was obtained with the developed model, allowing to propose the pad water temperature as an effective manipulated variable for designing an evaporative pad cooling control system. It was found that, for each Celsius degree that the water temperature decreased below the input wet bulb temperature, the output dry-bulb temperature decreased by 0.7 degrees C and the output relative humidity increased by 1%. (c) 2020 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:147 / 162
页数:16
相关论文
共 29 条
[1]   Validation of Halasz's non-dimensional model using cross-flow evaporative coolers used in greenhouses [J].
Al-Ismaili, Abdulrahim M. ;
Weatherhead, E. K. ;
Badr, O. .
BIOSYSTEMS ENGINEERING, 2010, 107 (02) :86-96
[2]  
ASABE, 2008, EP4064 ASABE ANSIASA
[3]  
ASHRAE, 2011, 2011 ASHRAE HDB HVAC
[4]  
ASHRAE, 2009, 2009 ASHRAE HDB FUND
[5]  
Camargo J. R., 2005, REV ENGENHARIA TERMI, V2, p30e34
[6]   Experimental performance of a direct evaporative cooler operating during summer in a Brazilian city [J].
Camargo, JR ;
Ebinuma, CD ;
Silveira, JL .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (07) :1124-1132
[7]  
Cengel Y., 2005, FLUID MECH FUNDAMENT
[8]  
Cengel Y. A., 2002, THERMODYNAMICS ENG A, V4th
[9]   A new approach to analysis and optimization of evaporative cooling system II: Applications [J].
Chen, Qun ;
Pan, Ning ;
Guo, Zeng-Yuan .
ENERGY, 2011, 36 (05) :2890-2898
[10]  
de Carvalho V. F., 2006, 35 C BRAS ENG AGR