共 7 条
Comparing static mixer performances at pilot and full scale for ozonation, inactivation of Bacillus subtilis, and bromate formation in water treatment
被引:4
|作者:
Mysore, C
Leparc, J
Lake, R
Agutter, P
Prévost, M
机构:
[1] USFilter, N Amer Technol Ctr, Norcross, GA 30092 USA
[2] Veolia Environm, Watford WD2 2LG, Herts, England
关键词:
ozone;
static mixers Bacillus subtilis spores;
disinfection performance;
bromate formation;
D O I:
10.1080/01919510490439609
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
The potential benefits of using a static mixer for ozone dissolution was evaluated through comprehensive pilot- and full-scale studies under a variety of operating conditions and source waters. The static mixer pilot unit was operated side-by-side to a full-scale plant which also employed static mixers for ozonation. Based on the results obtained from this pilot study (and at other sites), it appears that an optimal ozone dose (less than or equal to0.5 mg O-3/mg C) applied through a static mixer dissolution system integrated with a well-designed downstream contactor can result in enhanced microbial inactivation while keeping bromate formation below 10 mug/L.