Experimental investigation of negative DC corona on conductor bundles: A comparison with positive corona

被引:0
作者
Bousiou, E. I. [1 ]
Mikropoulos, P. N. [1 ]
Zagkanas, V. N. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Elect & Comp Engn, Fac Engn, High Voltage Lab, Thessaloniki 54124, Greece
来源
2017 52ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC) | 2017年
关键词
Conductor bundles; corona; direct current; electrical discharges; overhead lines; power losses; transmission; SURFACE CONDITIONS; COAXIAL CYLINDERS; PROGRESS REPORT; SPACE-CHARGE; TEST LINE; AIR; MOBILITY; IONS; HUMIDITY; LOSSES;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Negative DC corona on conductor bundles is experimentally investigated in the coaxial configuration. The dependence of the corona characteristics, namely inception voltage and current, thus also inception field and power losses, on bundle radius and number of conductors in the bundle is assessed. The corona inception voltage of conductor bundles is highest at a bundle radius that corresponds to the minimum electric field strength at the conductor surface. The corona inception field strength of conductor bundles can be considered, with reasonable accuracy, as equal to that of the single conductor. Polarity effects on DC corona characteristics are assessed through comparisons with positive DC corona. For both polarities of applied voltage, the corona current can be accurately estimated through a modified Townsend quadratic formula using appropriate values for ion mobility.
引用
收藏
页数:5
相关论文
共 32 条
[1]   Analysis of corona losses on monopolar dc transmission lines [J].
Abdel-Salam, M ;
Mufti, A .
ELECTRIC POWER SYSTEMS RESEARCH, 1998, 44 (02) :145-154
[2]   CALCULATION OF CORONA V-I CHARACTERISTICS OF MONOPOLAR BUNDLES USING THE CHARGE SIMULATION METHOD [J].
ABDELSALAM, M ;
ABDELSATTAR, S .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1989, 24 (04) :669-679
[3]   CORONA PHENOMENA FROM WATER DROPS ON SMOOTH CONDUCTORS UNDER HIGH DIRECT VOLTAGE [J].
AKAZAKI, M .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1965, PA84 (01) :1-&
[4]   Finite-element solution of monopolar corona on bundle conductors [J].
Al-Hamouz, ZM ;
Abdel-Salam, M .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (02) :380-386
[5]   Corona power loss on bundled conductors: Experimental and computational results [J].
Al-Hamouz, ZM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1999, 35 (06) :1277-1283
[6]   TRANSMISSION-LINES - EFFECT OF EARTH RESISTIVITY ON MAGNETIC-FIELD, IMAGES AND EQUIVALENT-CIRCUIT [J].
PERZ, MC ;
RAGHUVEER, MR .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (06) :2135-2143
[7]   PROGRESS REPORT ON BPA HV DC TEST LINE RADIO NOISE AND CORONA LOSS [J].
BAILEY, BM .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1967, PA86 (10) :1141-&
[8]  
Bousiou E. I., 2016, P 51 INT U POW ENG C
[9]   Effect of the humidity in the ionic mobility in reduced air-density [J].
Calva, PA ;
Espino, F .
1998 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS 1 AND 2, 1998, :508-511
[10]   The effect of water vapor on the mobility of gaseous ions in air [J].
Erikson, HA .
PHYSICAL REVIEW, 1928, 32 (05) :0791-0794