Echocardiographic Assessment of Prosthetic Valves

被引:2
作者
Ashraf, Hasan [1 ]
Freeman, William K. [2 ]
机构
[1] Yale Univ, Sch Med, Dept Cardiol, New Haven, CT 06510 USA
[2] Mayo Clin, Dept Cardiovasc Dis, Div Echocardiog, Scottsdale, AZ 85259 USA
关键词
prosthetic cardiac valves; echocardiography; Doppler; mechanical valve; bioprosthetic valve; structural valve degeneration; prosthetic valve thrombosis; VENTRICULAR MASS REGRESSION; AORTIC-VALVE; PATIENT MISMATCH; PULMONARY REGURGITATION; TRICUSPID REGURGITATION; EUROPEAN ASSOCIATION; QUANTITATIVE-EVALUATION; MECHANICAL PROSTHESES; BIOPROSTHETIC VALVES; AMERICAN SOCIETY;
D O I
10.31083/j.rcm2310343
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Prosthetic valves are increasingly encountered in clinical practice. A grasp of the intricacies of the assessment and management of prosthetic valves is thus a crucial skillset for the practicing cardiologist. Echocardiography is the imaging modality of choice for the anatomic and functional evaluation of prosthetic valve. This document reviews the general features of prosthetic valves, echocardiographic identification of normally functioning and dysfunctional prosthetic valves as well as echocardiographic diagnosis of specific prosthetic valvular abnormalities.
引用
收藏
页数:15
相关论文
共 64 条
[1]  
Aksöyek A, 2004, J HEART VALVE DIS, V13, P641
[2]  
Bernet FH, 2007, J HEART VALVE DIS, V16, P151
[3]   Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement [J].
Blais, C ;
Dumesnil, JG ;
Baillot, R ;
Simard, S ;
Doyle, D ;
Pibarot, P .
CIRCULATION, 2003, 108 (08) :983-988
[4]   Comprehensive Echocardiographic Assessment of Mechanical Tricuspid Valve Prostheses Based on Early Post-Implantation Echocardiographic Studies [J].
Blauwet, Lori A. ;
Burkhart, Harold M. ;
Dearani, Joseph A. ;
Malouf, Joseph F. ;
Connolly, Heidi M. ;
Hodge, David O. ;
Herges, Regina M. ;
Miller, Fletcher A., Jr. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (04) :414-424
[5]   Comprehensive Echocardiographic Assessment of the Hemodynamic Parameters of 285 Tricuspid Valve Bioprostheses Early after Implantation [J].
Blauwet, Lori A. ;
Danielson, Gordon K. ;
Burkhart, Harold M. ;
Dearani, Joseph A. ;
Malouf, Joseph F. ;
Connolly, Heidi M. ;
Hodge, David O. ;
Herges, Regina M. ;
Miller, Fletcher A., Jr. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (10) :1045-U72
[6]   Prospective randomized comparison of CarboMedics and St. Jude Medical bileaflet mechanical heart valve prostheses: Ten-year follow-up [J].
Bryan, Alan J. ;
Rogers, Chris A. ;
Bayliss, Kate ;
Wild, Jan ;
Angelini, Gianni D. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (03) :614-U35
[7]   Nominal size in six bileaflet mechanical aortic valves: A comparison of orifice size and biologic equivalence [J].
Chambers, JB ;
Oo, L ;
Narracott, A ;
Lawford, PM ;
Blauth, CI .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (06) :1388-1393
[8]   RIGHT-VENTRICULAR OUTFLOW RECONSTRUCTION WITH CRYOPRESERVED HOMOGRAFTS IN PEDIATRIC-PATIENTS - INTERMEDIATE-TERM FOLLOW-UP WITH SERIAL ECHOCARDIOGRAPHIC ASSESSMENT [J].
CHAN, KC ;
FYFE, DA ;
MCKAY, CA ;
SADE, RM ;
CRAWFORD, FA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (02) :483-489
[9]   On-X Valve The Next Generation Aortic Valve [J].
Chaudhary, Rahul ;
Garg, Jalaj ;
Krishnamoorthy, Parasuram ;
Shah, Neeraj ;
Feldman, Bruce A. ;
Martinez, Matthew W. ;
Freudenberger, Ronald .
CARDIOLOGY IN REVIEW, 2017, 25 (02) :77-83
[10]   Three-Dimensional Color Doppler Echocardiographic Quantification of Tricuspid Regurgitation Orifice Area: Comparison with Conventional Two-Dimensional Measures [J].
Chen, Tien-En ;
Kwon, Susan H. ;
Enriquez-Sarano, Maurice ;
Wong, Benjamin F. ;
Mankad, Sunil V. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2013, 26 (10) :1143-1152