Methods for modeling and predicting mechanical deformations of the breast under external perturbations

被引:112
作者
Azar, FS
Metaxas, DN
Schnall, MD
机构
[1] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Comp Sci, Philadelphia, PA 19104 USA
[3] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
MRI; finite element modeling; breast cancer; soft tissue modeling;
D O I
10.1016/S1361-8415(01)00053-6
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Currently, high field (1.5 T) superconducting MR imaging does not allow live guidance during needle breast procedures. The current procedure allows the physician only to calculate approximately the location and extent of a cancerous tumor in the compressed patient breast before inserting the needle. It can then become relatively uncertain that the tissue specimen removed during the biopsy actually belongs to the lesion of interest. A new method for guiding clinical breast biopsy is presented, based on a deformable finite element model of the breast. The geometry of the model is constructed from MR data, and its mechanical proper-ties are modeled using a non-linear material model. This method allows imaging the breast without or with mild compression before the procedure, then compressing the breast and using the finite element model to predict the tumor's position during the procedure. A silicon phantom containing a stiff inclusion was imaged uncompressed then compressed. A model of the phantom was constructed and compressed using custom-written software, and also using a commercial FEM simulation package. The displacement of the inclusion's corners was recorded both in the real phantom and in the two compressed models. A patient's breast was imaged uncompressed then compressed. A deformable model of the uncompressed breast was constructed, then compressed. The displacement of a cyst and of two vitamin E pills taped to the surface of the breast were recorded both in the real and in the modeled breast. The entire procedure lasted less than a half-hour, making it clinically useful, The results show that it is possible to create a deformable model of the breast based on finite elements with non-linear material properties, capable of modeling and predicting breast deformations in a clinically useful amount of time. (C) 2002 Elsevier Science BY, All rights reserved.
引用
收藏
页码:1 / 27
页数:27
相关论文
共 66 条
  • [1] MECHANICAL-PROPERTIES AND YOUNGS MODULUS OF HUMAN-SKIN INVIVO
    AGACHE, PG
    MONNEUR, C
    LEVEQUE, JL
    DERIGAL, J
    [J]. ARCHIVES OF DERMATOLOGICAL RESEARCH, 1980, 269 (03) : 221 - 232
  • [2] Azar F, 1999, P INT SOC MAGN RESON, V7, P1084
  • [3] AZAR FS, 2001, J ACAD RADIOL OCT
  • [4] AZAR FS, 2000, 26 IEEE ANN NE BIOEN
  • [5] Baumann R., 1996, MED MEETS VIRTUAL RE
  • [6] Behrenbruch CP, 2000, LECT NOTES COMPUT SC, V1935, P307
  • [7] Algorithms for fuzzy segmentation
    Carvalho, BM
    Gau, CJ
    Herman, GT
    Kong, TY
    [J]. PATTERN ANALYSIS AND APPLICATIONS, 1999, 2 (01) : 73 - 81
  • [8] Chadwick J. E., 1989, Computer Graphics, V23, P243, DOI 10.1145/74334.74358
  • [9] Pump it up: computer animation of a biomechanically based model of muscle using the finite element method
    Chen, David T.
    Zeltzer, David
    [J]. Computer Graphics (ACM), 1992, 26 (02): : 89 - 98
  • [10] COOK RD, 1989, CONCEPRTS APPL FINIT