In this paper, a multi-purpose hybrid desiccant integrated vapor-compression air-conditioning system of a small capacity is experimentally investigated. The system, referred as hybrid desiccant-assisted air conditioner (HDAC), is designed to meet the cooling load of spaces having large latent heat portions and at the same time to extract water from atmospheric air. The system is mainly consisted of a liquid-desiccant dehumidification unit integrated with a vapor-compression system (VCS). The dehumidification unit uses lithium chloride (LiCl) solution as the working material. The effect of different parameters, such as desiccant solution flow rate, process airflow rate, evaporator and condenser temperatures, strong solution concentration and regeneration temperature on the performance of the system, is studied. This system has a water recovery rate of 6.7?l/h?TR (1.91?l/h?kW) of pure water at typical north Egyptian climate (2030 degrees C dry bulb and 3545% relative humidity). The HDAC system has a COP as high as 3.8 (an improvement of about 68% over the conventional VCS). The system offers a total cooling capacity of about 1.75?TR (6.15?kW) using a 0.75?TR (2.6?kW) VCS unit. Finally, the proposed system is found to have a payback time of about 10 months without any considerable extra capital cost compared with the known split air-conditioning system. The results emphasize the potential benefits of the HDAC system. Copyright (c) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:535 / 544
页数:10
相关论文
共 17 条
[1]  
Ahmed CSK, 1997, APPL THERM ENG, V17, P125
[2]  
Burns PR., 1985, ASHRAE transactions, V91, P457
[3]  
Close DJ, 1982, AUSTR I REFR AIR CON
[4]   Use of liquid desiccant cooling to improve the performance of vapor compression air conditioning [J].
Dai, YJ ;
Wang, RZ ;
Zhang, HF ;
Yu, JD .
APPLIED THERMAL ENGINEERING, 2001, 21 (12) :1185-1202
[5]  
Duffie J.A., 1974, SOLAR ENG THERMAL PR, DOI DOI 10.1002/9781118671603
[6]   Use of desiccant dehumidification to improve energy utilization in air-conditioning systems in Beirut [J].
Ghaddar, N ;
Ghali, K ;
Najm, A .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (15) :1317-1338
[7]   Analysis on a hybrid desiccant air-conditioning system [J].
Jia, C. X. ;
Dai, Y. J. ;
Wu, J. Y. ;
Wang, R. Z. .
APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) :2393-2400
[8]   SENSITIVITY ANALYSIS AND COMPONENT MODELING OF A PACKED-TYPE LIQUID DESICCANT SYSTEM AT PARTIAL LOAD OPERATING-CONDITIONS [J].
KHAN, AY .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1994, 18 (07) :643-655
[9]   Proposed energy-efficient air-conditioning system using liquid desiccant [J].
Kinsara, AA ;
Elsayed, MM ;
AlRabghi, OM .
APPLIED THERMAL ENGINEERING, 1996, 16 (10) :791-806
[10]  
Kodama A, 2000, INT J ENERG RES, V24, P127