Use of Fine-threaded K-wires in the Treatment of Coronoid Fractures in Complex Elbow Instability

被引:9
作者
Giannicola, Giuseppe [1 ]
Polimanti, David [1 ]
Gumina, Stefano [1 ]
Cinotti, Gianluca [1 ]
机构
[1] Univ Roma La Sapienza, Dept Anat Histol Forens Med & Orthopaed Sci, I-00158 Rome, Italy
关键词
TERRIBLE-TRIAD INJURIES; MASON TYPE-III; RADIAL HEAD; FIXATION; STABILITY; RECONSTRUCTION; ULNA;
D O I
10.3928/01477447-20130920-12
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The coronoid process is one of the main elbow constraints that provides ulnohumeral joint stability. Coronoid fractures may be fixed using multiple techniques, including transosseous sutures, screws, and plates. The goal of this study was to analyze the clinical and radiographic outcomes in a series of patients with complex elbow instability in whom coronoid fractures were repaired using fine-threaded K-wires. Eight men and 10 women (mean age, 47 years) were followed prospectively for a mean of 26 months. Surgical treatment consisted of open reduction and internal fixation of all fractures; radial head replacement in Mason III injuries; lateral collateral ligament repair in all patients; and, in cases of persistent instability, medial collateral ligament repair, hinged fixator application, or both. Coronoid fixation was performed using 2 or more fine-threaded K-wires, depending on the fragment size, inserted from the posterior aspect of the ulna and directed toward the coronoid fragment using a 1-step fixation technique. At last follow-up, mean extension was 15, mean flexion was 133, mean pronation was 78, and mean supination was 69; mean Disabilities of the Arm, Shoulder and Hand score was 9.7, mean American Shoulder and Elbow Surgeons score was 85, and mean Mayo Elbow Performance Score was 89. According to the Mayo Elbow Performance Index, 10 excellent, 7 good, and 1 fair result were recorded. All but 1 patient had a stable elbow. Fracture healing was observed in all but 1 patient. No secondary coronoid fragment dislocation or implant failures were reported. This study shows that using fine-threaded K-wires provides easy, minimally invasive, stable, and successful 1-step fixation that can be used to obtain osteosynthesis of coronoid fractures in patients with complex elbow instability.
引用
收藏
页码:E1233 / E1238
页数:6
相关论文
共 37 条
[1]   Fractures of the coronoid: morphology based upon computer tomography scanning [J].
Adams, Julie E. ;
Sanchez-Sotelo, Joaquin ;
Kallina, Charles F. ;
Morrey, Bernard F. ;
Steinmann, Scott P. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2012, 21 (06) :782-788
[2]   RESULTS OF DELAYED EXCISION OF THE RADIAL HEAD AFTER FRACTURE [J].
BROBERG, MA ;
MORREY, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (05) :669-674
[3]   Coronoid Fractures [J].
Budoff, Jeffrey E. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (11) :2418-2423
[4]   The Comparative Stability of Screw Versus Plate Versus Screw and Plate Coronoid Fixation [J].
Budoff, Jeffrey E. ;
Meyers, D. Nicole ;
Ambrose, Catherine G. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (02) :238-245
[5]   The role of the coronoid process in elbow stability [J].
Closkey, RF ;
Goode, JR ;
Kirschenbaum, D ;
Cody, RP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (12) :1749-1753
[6]   Coronoid fracture patterns [J].
Doornberg, JN ;
Ring, D .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (01) :45-52
[7]   Coronoid fracture height in terrible-triad injuries [J].
Doornberg, Job N. ;
van Duijn, Joppe ;
Ring, David .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05) :794-797
[8]  
Gausepohl T, 2000, ORTHOFIX EXTERNAL FIXATION IN TRAUMA AND ORTHOPAEDICS, P375
[9]  
GAUSEPOHL T, 2001, INJURY S, V32, P1
[10]   Soft Tissue Constraint Injuries in Complex Elbow Instability: Surgical Techniques and Clinical Outcomes [J].
Giannicola, Giuseppe ;
Polimanti, David ;
Sacchetti, Federico M. ;
Scacchi, Marco ;
Bullitta, Gianluca ;
Manauzzi, Erica ;
Gumina, Stefano ;
Cinotti, Gianluca .
ORTHOPEDICS, 2012, 35 (12) :E1746-E1753