Improved desorption electrospray ionization mass spectrometry performance using edge sampling and a rotational sample stage

被引:21
作者
Kertesz, Vilmos [1 ]
Van Berkel, Gary J. [1 ]
机构
[1] Oak Ridge Natl Lab, Organ & Biol Mass Spectrometry Grp, Div Chem Sci, Oak Ridge, TN 37831 USA
基金
美国能源部;
关键词
D O I
10.1002/rcm.3812
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The position of the surface to be analyzed relative to the sampling orifice or capillary into the mass spectrometer has been known to dramatically affect the observed signal levels in desorption electrospray ionization mass spectrometry (DESI-MS). In analyses of sample spots on planar surfaces, DESI-MS signal intensities as much as five times greater were routinely observed when the bottom of the sampling capillary was appropriately positioned beneath the surface plane ('edge sampling') compared with when the capillary just touched the surface. To take advantage of the optimum 'edge sampling' geometry and to maximize the number of samples that could be analyzed in this configuration, a rotational sample stage was integrated into a typical DESI-MS setup. The rapid quantitative determination of caffeine in two diet sport drinks spiked with an isotopically labeled internal standard demonstrated the utility of this approach. Published in 2008 by John Wiley & Sons, Ltd.
引用
收藏
页码:3846 / 3850
页数:5
相关论文
共 17 条
[1]   Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570
[2]   Automated nanospray using chip-based emitters for the quantitative analysis of pharmaceutical compounds [J].
Corkery, LJ ;
Pang, H ;
Schneider, BB ;
Covey, TR ;
Siu, KWM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (03) :363-369
[3]   Simulation of atmospheric transport and droplet-thin film collisions in desorption electrospray ionization [J].
Costa, Anthony B. ;
Cooks, R. Graham .
CHEMICAL COMMUNICATIONS, 2007, (38) :3915-3917
[4]   Quantitative thin-layer chromatography/mass spectrometry analysis of caffeine using a surface sampling probe electrospray ionization tandem mass spectrometry system [J].
Ford, MJ ;
Deibel, MA ;
Tomkins, BA ;
Van Berkel, GJ .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4385-4389
[5]  
Kebarle P, 2000, J MASS SPECTROM, V35, P804, DOI 10.1002/1096-9888(200007)35:7<804::AID-JMS22>3.3.CO
[6]  
2-H
[7]   Scanning and surface alignment considerations in chemical imaging with desorption electrospray mass spectrometry [J].
Kertesz, Vilmos ;
van Berkel, Gary J. .
ANALYTICAL CHEMISTRY, 2008, 80 (04) :1027-1032
[8]   Desorption electrospray ionization mass spectrometry: direct toxicological screening and analysis of illicit Ecstasy tablets [J].
Leuthold, LA ;
Mandscheff, JF ;
Fathi, M ;
Giroud, C ;
Augsburger, M ;
Varesio, E ;
Hopfgartner, G .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (02) :103-110
[9]  
Miller J. C., 1988, STAT ANAL CHEM, P110
[10]   AP and vacuum MALDI on a QqLIT instrument [J].
Schneider, BB ;
Lock, C ;
Covey, TR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (02) :176-182