Polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in human liver and adipose tissue samples from Belgium

被引:135
|
作者
Covaci, Adrian [1 ,2 ]
Voorspoels, Stefan [1 ]
Roosens, Laurence [1 ]
Jacobs, Werner [3 ]
Blust, Ronny [2 ]
Neels, Hugo [1 ]
机构
[1] Univ Antwerp, Toxicol Ctr, B-2610 Antwerp, Belgium
[2] Univ Antwerp, Dept Biol, Ecophysiol Biochem & Toxicol Grp, B-2020 Antwerp, Belgium
[3] Univ Antwerp Hosp, Dept Forens Med, B-2650 Antwerp, Belgium
关键词
Polybrominated diphenyl ethers; Polychlorinated biphenyls; Human liver; Human adipose tissue; Age and gender dependency; Belgium;
D O I
10.1016/j.chemosphere.2008.02.059
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Levels of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) were measured in paired human adipose tissue and liver samples (n = 25) from Belgium. Average concentrations and standard deviation Of SUM PBDEs (congeners 28, 47, 99, 100, 153, 154 and 183) were 5.3 +/- 3.0 (range 1.4-13.2) and 3.6 +/- 2.1 (range 1.0-10.0) ng g(-1) lipid weight (lw) in adipose tissue and liver, respectively. These concentrations were similar to reported PBDE data from Belgium and were at the lower end of the concentration range reported elsewhere in the world. In both tissues under study, BDE 153 and BDE 47 were the Most abundant PBDE congeners, contributing approximately 35% and 25% to the total PBDE content. Average concentrations and range of PCBs (sum of 23 congeners) were 490(range 70-1130) and 380 (range 90-1140) ng g(-1) lw in adipose tissue and liver, respectively, No correlation between age and concentrations of PBDEs could be found (r = 0.04), while PCB concentrations correlated significantly with age (r = 0.62, p < 0.01, for the Suit) PCBs: r = 0.64, p < 0.01 for PCB 153 alone). Factors, such as exposure pathways (food, dust and air), rates of bioaccumulation, metabolism and elimination, influence the concentrations of PBDEs differently than those of PCBs in humans (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 50 条
  • [31] Determination of polybrominated diphenyl ethers (PBDEs) in fish samples from rivers and estuaries in Taiwan
    Peng, Jui-Hwa
    Huang, Chin-Wang
    Weng, Ying-Ming
    Yak, Hwa-Kwang
    CHEMOSPHERE, 2007, 66 (10) : 1990 - 1997
  • [32] Levels of dechloranes and polybrominated diphenyl ethers (PBDEs) in human serum from France
    Brasseur, Catherine
    Pirard, Catherine
    Scholl, Georges
    De Pauw, Edwin
    Viel, Jean-Francois
    Shen, Li
    Reiner, Eric J.
    Focant, Jean-Francois
    ENVIRONMENT INTERNATIONAL, 2014, 65 : 33 - 40
  • [33] Concentrations of polybrominated diphenyl ethers (PBDEs) in matched samples of human milk, dust and indoor air
    Toms, Leisa-Maree L.
    Hearn, Laurence
    Kennedy, Karen
    Harden, Fiona
    Bartkow, Michael
    Temme, Christian
    Mueller, Jochen F.
    ENVIRONMENT INTERNATIONAL, 2009, 35 (06) : 864 - 869
  • [34] Levels of Polychlorinated Biphenyls in Human Adipose Tissue Samples from Southeast China
    Wang, Na
    Kong, Deyang
    Cai, Daoji
    Shi, Lili
    Cao, Yanzhong
    Pang, Guofang
    Yu, Rongbin
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2010, 44 (11) : 4334 - 4340
  • [35] Occurrence and levels of polybrominated diphenyl ethers (PBDEs) in house dust and hair samples from Northern Poland; an assessment of human exposure
    Krol, Sylwia
    Namiesnik, Jacek
    Zabiegala, Bozena
    CHEMOSPHERE, 2014, 110 : 91 - 96
  • [36] Fast and efficient extraction methods for the analysis of polychlorinated biphenyls and polybrominated diphenyl ethers in biological matrices
    Tapie, N.
    Budzinski, H.
    Le Menach, K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (06) : 2169 - 2177
  • [37] Polypropylene membrane coated with carbon nanotubes functionalized with chitosan: Application in the microextraction of polychlorinated biphenyls and polybrominated diphenyl ethers from environmental water samples
    Ge, Dandan
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1408 : 56 - 62
  • [38] Fast and efficient extraction methods for the analysis of polychlorinated biphenyls and polybrominated diphenyl ethers in biological matrices
    N. Tapie
    H. Budzinski
    K. Le Ménach
    Analytical and Bioanalytical Chemistry, 2008, 391 : 2169 - 2177
  • [39] Polybrominated Diphenyl Ethers (PBDEs) and Hexabromocyclodecane (HBCD) in Composite US Food Samples
    Schecter, Arnold
    Haffner, Darrah
    Colacino, Justin
    Patel, Keyur
    Paepke, Olaf
    Opel, Matthias
    Birnbaum, Linda
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2010, 118 (03) : 357 - 362
  • [40] Assessment of human exposure to polychlorinated biphenyls and polybrominated diphenyl ethers in Japan using archived samples from the early 1980s and mid-1990s
    Koizumi, A
    Yoshinaga, T
    Harada, K
    Inoue, K
    Morikawa, A
    Muroi, J
    Inoue, S
    Eslami, B
    Fujii, S
    Fujimine, Y
    Hachiya, N
    Koda, S
    Kusaka, Y
    Murata, K
    Nakatsuka, H
    Omae, K
    Saito, N
    Shimbo, S
    Takenaka, K
    Takeshita, T
    Todoriki, H
    Wada, Y
    Watanabe, T
    Ikeda, M
    ENVIRONMENTAL RESEARCH, 2005, 99 (01) : 31 - 39