Variations in intraocular lens injector dimensions and corneal incision architecture after cataract surgery

被引:13
作者
Arboleda, Alejandro [1 ]
Arrieta, Esdras [1 ]
Aguilar, Mariela C. [1 ]
Sotolongo, Krystal [1 ]
Nankivil, Derek [1 ,2 ]
Parel, Jean-Marie A. [1 ,3 ]
机构
[1] Univ Miami, Miller Sch Med Res & Dev, Dept Ophthalmol, Ophthalm Biophys Ctr,Bascom Palmer Eye Inst, Miami, FL USA
[2] Johnson & Johnson Vis Care Inc, Res & Dev, Jacksonville, FL USA
[3] Univ Liege, Sart Tillman CHU, Dept Ophthalmol, Liege, Belgium
关键词
TEMPORAL CLEAR CORNEAL; INDUCED ASTIGMATISM; MOTORIZED INJECTOR; PHACOEMULSIFICATION; IMPLANTATION; WIDTH; ULTRASTRUCTURE; SAFETY; TRAUMA; SIZES;
D O I
10.1016/j.jcrs.2018.10.047
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the differences in intraocular lens (IOL) injectors and to assess the effect of IOL insertion on injector tips and eyes after cataract surgery in a rabbit model. Setting: Ophthalmic Biophysics Center, Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami Miller School of Medicine, Miami, Florida, USA. Design: Experimental study. Methods: A modified optical comparator was used to measure the tips of 13 IOL injector models to determine the perimeter, tip angle, and cone angle of each. Injectors were analyzed before and after IOL insertion. Surgery was performed on rabbits with 71 IOL injectors of 13 models, and custom gauges were used to determine the incision size before and after surgery. Results: The injector dimensions varied by model; tip diameter, tip angle, and cone angle ranged from 1.44 to 2.12 mm, 29.7 to 66.5 degrees and 0.6 to 10.8 degrees, respectively. The incision size through which surgery was successfully performed also varied by injector model; the initial incision sizes ranged from 2.0 to 2.63 mm. For all injectors, there was wound enlargement after IOL insertion that ranged from a 0.1 to 0.65 mm increase in incision length. Conclusions: The dimensions and injection systems varied with each IOL injector. All injectors led to postoperative wound stretch after IOL insertion, with no final incision measuring less than 2.0 mm. These findings suggest that the clear cornea incision should have a width corresponding to the injector diameter. (C) 2018 ASCRS and ESCRS
引用
收藏
页码:656 / 661
页数:6
相关论文
共 24 条
[1]   Final incision size after implantation of a hydrophobic acrylic aspheric intraocular lens: New motorized injector versus standard manual injector [J].
Allen, David ;
Habib, Maged ;
Steel, David .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02) :249-255
[2]  
DENHAM D, 1989, OPHTHALMIC SURG LAS, V20, P794
[3]   Incision sizes at different stages of phacoemulsification with foldable intraocular lens implantation [J].
Espiritu, Cesar Ramon G. ;
Bernardo, Juanchito P., Jr. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12) :2115-2120
[4]   Postoperative corneal shape changes: Microincision versus small-incision coaxial cataract surgery [J].
Hayashi, Ken ;
Yoshida, Motoaki ;
Hayashi, Hideyuki .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (02) :233-239
[5]   Wound Integrity of 2.0 mm Transconjunctival Single-Plane Sclerocorneal Incision: A Comparison between a Motorized Injector with/without Pause Time and a Manual Injector [J].
Imai, Hisanori ;
Fujii, Ayaka ;
Tani, Emiko ;
Azumi, Atsushi .
JOURNAL OF OPHTHALMOLOGY, 2016, 2016
[6]   The impact of a preloaded intraocular lens delivery system on operating room efficiency in routine cataract surgery [J].
Jones, Jason J. ;
Chu, Jeffrey ;
Graham, Jacob ;
Zaluski, Erge ;
Rocha, Guillermo .
CLINICAL OPHTHALMOLOGY, 2016, 10 :1123-1129
[7]   Comparison of new motorized injector vs manual injector for implantation of foldable intraocular lenses on wound integrity: an ASOCT study [J].
Khokhar, S. ;
Sharma, R. ;
Patil, B. ;
Aron, N. ;
Gupta, S. .
EYE, 2014, 28 (10) :1174-1178
[8]   Intraocular Lens Injector-Induced Stress on the Corneal Incisions During Lens Implantation [J].
Kleinmann, Guy ;
Kleinmann, Itzhak .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (01) :185-191
[9]   COMPARISON OF THE INDUCED ASTIGMATISM AFTER TEMPORAL CLEAR CORNEAL TUNNEL INCISIONS OF DIFFERENT SIZES [J].
KOHNEN, T ;
DICK, B ;
JACOBI, KW .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (04) :417-424
[10]   Incision sizes before and after implantation of SN60WF intraocular lenses using the Monarch injector system with C and D cartridges [J].
Kohnen, Thomas ;
Klaproth, Oliver K. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10) :1748-1753