Theoretical performance analysis of a new hybrid air conditioning system with two-stage energy recovery in cold winter

被引:5
作者
Yang, Yang [1 ]
Ren, Chengqin [1 ]
Tu, Min [2 ]
Luo, Baojun [1 ]
Fu, Jianqin [1 ]
机构
[1] Hunan Univ, Coll Mech & Vehicle Engn, State Key Lab Adv Design & Mfg Vehicle Body, Changsha 410082, Hunan, Peoples R China
[2] Univ South China, Sch Civil Engn, Hengyang 421001, Peoples R China
关键词
Hybrid air conditioning system; Energy recovery; Mechanical vapor compression system; Parametric analysis; Energy-saving potential; MASS-TRANSFER PROCESSES; EXCHANGERS;
D O I
10.1016/j.ijrefrig.2020.03.028
中图分类号
O414.1 [热力学];
学科分类号
摘要
Energy recovery technologies can effectively improve the energy efficiency of air-conditioning systems and significantly reduce building energy consumption. In this paper, a parametric analysis and energy-saving potential evaluation for a new hybrid air conditioning system (HAC) is carried out theoretically based on developed models. The proposed HAC incorporates into a conventional mechanical vapor compression air conditioning system with an independent fresh air conditioner which is composed of a network of heat exchangers, including a packed bed and three air-water finned coils. Under cold winter climate, in the fresh air conditioner, a packed bed is coupled with a water-air heat exchange coil to form a total energy recovery loop. A run-around sensible energy recovery loop is also integrated in the system to produce a two-stage energy recovery effect. Moreover, a sprayer is installed upstream of the two-stage energy recovery process for fresh air humidification, and a fresh air recirculation duct is equipped for frost-free operation. In the parametric analysis, four independent affecting parameters are included: the air-to-water heat capacity ratio, the indoor temperature, the ambient temperature, and the ratio of recirculation fresh air. The energy-saving potential of the HAC is also evaluated for applications in seven typical cities located in middle-lower Yangtze River region of China over the winter period (December, January and February). The results show that compared with the conventional system with electric humidification, the HAC has an average energy saving rate of 44.0%, and its average power saving per hour is 13.41 W m(-2). (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 36 条
  • [31] Theoretical analysis on heat and mass transfer in a direct evaporative cooler
    Wu, J. M.
    Huang, X.
    Zhang, H.
    [J]. APPLIED THERMAL ENGINEERING, 2009, 29 (5-6) : 980 - 984
  • [32] Research and applications of evaporative cooling in China: A review (II)-Systems and equipment
    Xuan, Y. M.
    Xiao, F.
    Niu, X. F.
    Huang, X.
    Wang, S. W.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05) : 3523 - 3534
  • [33] Yan D., 2004, HV AC, V7, P48
  • [34] Yang Tao, 2006, Journal of Shanghai Jiaotong University, V40, P1365
  • [35] Energy saving potential of two-stage compression dual-temperature air conditioning system
    Yu L.
    Ren C.
    Yang Y.
    Wan Y.
    Wang Z.
    [J]. Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2019, 50 (10): : 2595 - 2602
  • [36] Energy saving obtainable by applying a commercially available M-cycle evaporative cooling system to the air conditioning of an office building in North Italy
    Zanchini, Enzo
    Naldi, Claudia
    [J]. ENERGY, 2019, 179 : 975 - 988