Flow reversal effects on buoyancy induced air flow in a solar chimney

被引:73
作者
Khanal, Rakesh [1 ]
Lei, Chengwang [1 ]
机构
[1] Univ Sydney, Sch Civil Engn, Sydney, NSW 2006, Australia
关键词
Natural convection; Solar chimney; Reverse flow; Penetration depth; Ventilation; NATURAL VENTILATION; VERTICAL CHANNEL; HEAT-FLUX; CONVECTION; WALL; BUILDINGS;
D O I
10.1016/j.solener.2012.06.015
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper reports a numerical investigation of flow reversal effects on the buoyancy induced air flow in a solar chimney for ventilation applications over a range of controlling parameters. The reverse flow phenomenon is quantitatively examined by calculating its penetration depth. In order to suppress the reverse flow and enhance ventilation performance, a configuration with an inclined passive wall is proposed as a new design; the effectiveness of this design has been examined over the Rayleigh number range of 10(9) <= Ra <= 10(11). It is identified that there exists an optimum inclination angle corresponding to an optimum aspect ratio at which the mass flow rate is the maximum for a given Rayleigh number. The numerical results are supported by a scaling argument and a flow visualization experiment. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2783 / 2794
页数:12
相关论文
共 23 条
[1]   Thermal and fluid dynamic behaviors in symmetrical heated channel-chimney systems [J].
Andreozzi, Assunta ;
Buonomo, Bernardo ;
Manca, Oronzio .
INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2010, 20 (6-7) :811-833
[2]   Experimental study for natural ventilation on a solar chimney [J].
Arce, J. ;
Jimenez, M. J. ;
Guzman, J. D. ;
Heras, M. R. ;
Alvarez, G. ;
Xaman, J. .
RENEWABLE ENERGY, 2009, 34 (12) :2928-2934
[3]   Scaling investigation of the natural convection boundary layer on an evenly heated plate [J].
Armfield, S. W. ;
Patterson, John C. ;
Lin, Wenxian .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (7-8) :1592-1602
[4]   Study of the natural convection phenomena inside a wall solar chimney with one wall adiabatic and one wall under a heat flux [J].
Bacharoudis, Evangellos ;
Vrachopoulos, Michalis Gr. ;
Koukou, Maria K. ;
Margaris, Dionysios ;
Filios, Andronikos E. ;
Mavrommatis, Stamatis A. .
APPLIED THERMAL ENGINEERING, 2007, 27 (13) :2266-2275
[5]   Modeling of window-sized solar chimneys for ventilation [J].
Bansal, NK ;
Mathur, J ;
Mathur, S ;
Jain, M .
BUILDING AND ENVIRONMENT, 2005, 40 (10) :1302-1308
[6]   An analytical and numerical study of solar chimney use for room natural ventilation [J].
Bassiouny, Ramadan ;
Koura, Nader S. A. .
ENERGY AND BUILDINGS, 2008, 40 (05) :865-873
[7]   Air flow and thermal efficiency characteristics in solar chimneys and Trombe Walls [J].
Burek, S. A. M. ;
Habeb, A. .
ENERGY AND BUILDINGS, 2007, 39 (02) :128-135
[8]   Investigation on thermal performance of glazed solar chimney walls [J].
Chantawong, P ;
Hirunlabh, J ;
Zeghmati, B ;
Khedari, J ;
Teekasap, S ;
Win, MM .
SOLAR ENERGY, 2006, 80 (03) :288-297
[9]   An experimental investigation of a solar chimney model with uniform wall heat flux [J].
Chen, ZD ;
Bandopadhayay, P ;
Halldorsson, J ;
Byrjalsen, C ;
Heiselberg, P ;
Li, Y .
BUILDING AND ENVIRONMENT, 2003, 38 (07) :893-906
[10]   Experimental verification of induced ventilation [J].
Drori, U ;
Dubovsky, V ;
Ziskind, G .
JOURNAL OF ENVIRONMENTAL ENGINEERING, 2005, 131 (05) :820-826