Contrast-enhanced ultrasonography parameters in neural network diagnosis of liver tumors

被引:57
作者
Streba, Costin Teodor [1 ]
Ionescu, Mihaela [2 ]
Gheonea, Dan Ionut [1 ]
Sandulescu, Larisa [1 ]
Ciurea, Tudorel [1 ]
Saftoiu, Adrian [1 ]
Vere, Cristin Constantin [1 ]
Rogoveanu, Ion [1 ]
机构
[1] Univ Med & Pharm Craiova, Res Ctr Gastroenterol & Hepatol, Craiova 200349, Romania
[2] Univ Med & Pharm Craiova, Dept Bioinformat & Stat, Craiova 200349, Romania
关键词
Hepatocellular carcinoma; Liver tumors; Contrast enhanced ultrasound; Time-intensity curve; Artificial neural network; Computer-aided diagnosis system; DIFFERENTIAL-DIAGNOSIS; DECISION-SUPPORT; LESIONS; ULTRASOUND; ELASTOGRAPHY; METASTASIS; PREDICTION; CIRRHOSIS; CANCER;
D O I
10.3748/wjg.v18.i32.4427
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
AIM: To study the role of time-intensity curve (TIC) analysis parameters in a complex system of neural networks designed to classify liver tumors. METHODS: We prospectively included 112 patients with hepatocellular carcinoma (HCC) (n = 41), hyper-vascular (n = 20) and hypovascular (n = 12) liver metastases, hepatic hemangiomas (n = 16) or focal fatty changes (n = 23) who underwent contrast-enhanced ultrasonography in the Research Center of Gastroenterology and Hepatology, Craiova, Romania. We recorded full length movies of all contrast uptake phases and post-processed them offline by selecting two areas of interest (one for the tumor and one for the healthy surrounding parenchyma) and consecutive TIC analysis. The difference in maximum intensities, the time to reaching them and the aspect of the late/portal phase, as quantified by the neural network and a ratio between median intensities of the central and peripheral areas were analyzed by a feed forward back propagation multi-layer neural network which was trained to classify data into five distinct classes, corresponding to each type of liver lesion. RESULTS: The neural network had 94.45% training accuracy (95% CI: 89.31%-97.21%) and 87.12% testing accuracy (95% CI: 86.83%-93.17%). The automatic classification process registered 93.2% sensitivity, 89.7% specificity, 94.42% positive predictive value and 87.57% negative predictive value. The artificial neural networks (ANN) incorrectly classified as hemangyomas three HCC cases and two hyper-vascular metastases, while in turn misclassifying four liver hemangyomas as HCC (one case) and hypervascular metastases (three cases). Comparatively, human interpretation of TICs showed 94.1% sensitivity, 90.7% specificity, 95.11% positive predictive value and 88.89% negative predictive value. The accuracy and specificity of the ANN diagnosis system was similar to that of human interpretation of the TICs (P = 0.225 and P = 0.451, respectively). Hepatocellular carcinoma cases showed contrast uptake during the arterial phase followed by wash-out in the portal and first seconds of the late phases. For the hypovascular metastases did not show significant contrast uptake during the arterial phase, which resulted in negative differences between the maximum intensities. We registered wash-out in the late phase for most of the hypervascular metastases. Liver hemangiomas had contrast uptake in the arterial phase without agent wash-out in the portal-late phases. The focal fatty changes did not show any differences from surrounding liver parenchyma, resulting in similar TIC patterns and extracted parameters. CONCLUSION: Neural network analysis of contrast-enhanced ultrasonography - obtained TICs seems a promising field of development for future techniques, providing fast and reliable diagnostic aid for the clinician. (C) 2012 Baishideng. All rights reserved.
引用
收藏
页码:4427 / 4434
页数:8
相关论文
共 50 条
[31]   Liver tumors: Evaluation with contrast-enhanced ultrasound [J].
Cosgrove, D ;
Blomley, M .
ABDOMINAL IMAGING, 2004, 29 (04) :446-454
[32]   Short-term evaluation of liver tumors after transarterial chemoembolization: limitations and feasibility of contrast-enhanced ultrasonography [J].
Moschouris, Hippocrates ;
Malagari, Katerina ;
Papadaki, Marina Georgiou ;
Kornezos, Ioannis ;
Gkoutzios, Panagiotis ;
Tepelenis, Nikolaos ;
Matsaidonis, Dimitrios .
ABDOMINAL IMAGING, 2011, 36 (06) :718-728
[33]   VueBox® for quantitative analysis of contrast-enhanced ultrasound in liver tumors [J].
Dong, Yi ;
Koch, Jonas B. H. ;
Loewe, Axel L. ;
Christen, Michael ;
Wang, Wen-Ping ;
Jung, Ernst-Michael ;
Mohaupt, Markus G. ;
Dietrich, Christoph F. .
CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2022, 80 (04) :473-486
[34]   Contrast-Enhanced Intraoperative Ultrasound of the Liver [J].
Chang, Gloria Y. ;
Fetzer, David T. ;
Porembka, Matthew R. .
SURGICAL ONCOLOGY CLINICS OF NORTH AMERICA, 2022, 31 (04) :707-719
[35]   VALUE OF CONVENTIONAL ULTRASONOGRAPHY WITH CONTRAST-ENHANCED ULTRASONOGRAPHY IN THE DIFFERENTIAL DIAGNOSIS OF PARTIAL CYSTIC THYROID NODULES [J].
Song, Qing ;
Tian, Xiaoqi ;
Jiao, Ziyu ;
Yan, Lin ;
Lan, Yu ;
Zhu, Yaqiong ;
Luo, Yukun .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (09) :2494-2501
[36]   Contrast-enhanced ultrasonography with a new contrast agent (SonoVue®) for characterization of renal tumors [J].
Wang, Fei ;
Kang, Xinli ;
Cen, Song ;
Dai, Yuping ;
Deng, Chunhua ;
Wang, Weifu .
BIOMEDICAL RESEARCH-INDIA, 2017, 28 (11) :5148-5152
[37]   Comparison of contrast-enhanced ultrasonography and contrast-enhanced computed tomography in the diagnosis of cystic renal cell carcinoma [J].
Yuan, Xinchun ;
Zhou, Aiyun ;
Chen, Li ;
Xu, Pan ;
Zhang, Cheng ;
Zhang, Yan .
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (07) :10820-10826
[38]   Contrast-enhanced harmonic endoscopic ultrasonography for differential diagnosis of submucosal tumors of the upper gastrointestinal tract [J].
Kamata, Ken ;
Takenaka, Mamoru ;
Kitano, Masayuki ;
Omoto, Shunsuke ;
Miyata, Takeshi ;
Minaga, Kosuke ;
Yamao, Kentaro ;
Imai, Hajime ;
Sakurai, Toshiharu ;
Watanabe, Tomohiro ;
Nishida, Naoshi ;
Chikugo, Takaaki ;
Chiba, Yasutaka ;
Imamoto, Haruhiko ;
Yasuda, Takushi ;
Lisotti, Andrea ;
Fusaroli, Pietro ;
Kudo, Masatoshi .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2017, 32 (10) :1686-1692
[39]   Contrast-enhanced Ultrasonography for the Diagnosis of Frozen Shoulder [J].
Mezian, Kamal ;
Chang, Ke-Vin .
JOURNAL OF MEDICAL ULTRASOUND, 2019, 27 (03) :146-147
[40]   Principle of contrast-enhanced ultrasonography [J].
Mine, Yoshitaka ;
Takada, Etsuo ;
Sugimoto, Katsutoshi ;
Moriyasu, Fuminori .
JOURNAL OF MEDICAL ULTRASONICS, 2024, 51 (04) :567-580