This paper presents a new type of micro-inductor sensor for intraocular pressure (IOP) measurement on soft contact lens substructure. The sensor was designed and fabricated by using MEMS fabrication technologies. The contact lens is for wearing on a cornea such that a curvature of the contact lens corresponds substantially to that of the cornea, and is preferably made of Hydroxyethylmethacrylate (HEMA) by cast-molding method of soft contact lens for high oxygen permeability and comfortable long-duration wearing. In this paper, we discuss a contact lens with micro-inductor measurement principle followed by a brief description of our sensor design and fabrication. Our first prototype without wireless has been tested in lab-simulation bench. We obtain a simulation and measurement results have good linearity between micro-inductor radius variation and oscillation frequency. In future work will be to optimize the fabrication technology and the design to reach a better resolution, also a radio frequency integrated circuit (RFIC) and antenna will be designed preferably embedded in the contact lens so that inductance value transfers to frequency value via LC oscillator circuit and transmits intraocular pressure sensing signal by wireless telemetry system.
引用
收藏
页码:1644 / 1647
页数:4
相关论文
共 50 条
[41]   Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma [J].
Tae Yeon Kim ;
Jee Won Mok ;
Sang Hoon Hong ;
Sang Hoon Jeong ;
Hyunsik Choi ;
Sangbaie Shin ;
Choun-Ki Joo ;
Sei Kwang Hahn .
Nature Communications, 13
[42]   Intraocular Pressure Monitoring Using Moire Patterns Generated from a Contact Lens [J].
Wang, I-Jong ;
Wang, Lon A. ;
Lin, Pin-Chung .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
[43]   24-Hour Monitoring of Intraocular Pressure Fluctuations Using a Contact Lens Sensor: Diagnostic Performance for Glaucoma Progression [J].
Gaboriau, Thibaut ;
Dubois, Remi ;
Foucque, Boris ;
Malet, Florence ;
Schweitzer, Cedric .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (03)
[44]   Continuous 24 h monitoring of changes in intraocular pressure with the wireless contact lens sensor Triggerfish™. First results in patients [J].
Faschinger, C. ;
Mossboeck, G. .
OPHTHALMOLOGE, 2010, 107 (10) :918-922
[45]   Changes in corneal biomechanical properties after 24 hours of continuous intraocular pressure monitoring using a contact lens sensor [J].
Morales-Fernandez, Laura ;
Garcia-Bella, Javier ;
Martinez-de-la-Casa, Jose M. ;
Sanchez-Jean, Ruben ;
Saenz-Frances, Federico ;
Arriola-Villalobos, Pedro ;
Perucho, Lucia ;
Santos-Bueso, Enrique ;
Garcia-Feijoo, Julian .
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (03) :236-241
[46]   Tolerability of 24-Hour Intraocular Pressure Monitoring of a Pressure-sensitive Contact Lens [J].
Lorenz, Katrin ;
Korb, Christina ;
Herzog, Nicola ;
Vetter, Jan M. ;
Elflein, Heike ;
Keilani, Munir M. ;
Pfeiffer, Norbert .
JOURNAL OF GLAUCOMA, 2013, 22 (04) :311-316
[47]   Design of A Chipless Sensor System for Continuous Intraocular Pressure Monitoring [J].
Yang, Qi ;
Sun, Lu-Yang ;
Zhan, Jun-Lin ;
Ding, Cong ;
Chen, Hao ;
Liu, Zhen-Guo ;
Lu, Wei-Bing .
2022 IEEE 10TH ASIA-PACIFIC CONFERENCE ON ANTENNAS AND PROPAGATION, APCAP, 2022,
[48]   Commentary: Contact lens sensor-measured circadian intraocular pressure and glaucoma progression [J].
Krishnadas, R. .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (11) :2433-2434
[49]   Corneal thickness after overnight wear of an intraocular pressure fluctuation contact lens sensor [J].
Freiberg, Florentina J. ;
Lindell, Jeanette ;
Thederan, Luisa A-L ;
Leippi, Swetlana ;
Shen, Yanan ;
Klink, Thomas .
ACTA OPHTHALMOLOGICA, 2012, 90 (07) :E534-E539
[50]   Fluctuations of the Intraocular Pressure in Pseudoexfoliation Syndrome and Normal Eyes Measured by a Contact Lens Sensor [J].
Tojo, Naoki ;
Hayashi, Atsushi ;
Otsuka, Mitsuya ;
Miyakoshi, Akio .
JOURNAL OF GLAUCOMA, 2016, 25 (05) :E463-E468