Design and Fabricate a Contact Lens Sensor with a Micro-Inductor Embedded for Intraocular Pressure Monitoring

被引:0
作者
Tseng, Chien-Kai [1 ]
Huang, Yu-Chieh [1 ]
Tsai, Shang-Wei [1 ]
Yeh, Guan-Ting [1 ]
Chang, Chung-Hao [1 ]
Chiou, Jin-Chern [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Elect Engn, Hsinchu 30010, Taiwan
来源
2012 IEEE SENSORS PROCEEDINGS | 2012年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new type of micro-inductor sensor for intraocular pressure (IOP) measurement on soft contact lens substructure. The sensor was designed and fabricated by using MEMS fabrication technologies. The contact lens is for wearing on a cornea such that a curvature of the contact lens corresponds substantially to that of the cornea, and is preferably made of Hydroxyethylmethacrylate (HEMA) by cast-molding method of soft contact lens for high oxygen permeability and comfortable long-duration wearing. In this paper, we discuss a contact lens with micro-inductor measurement principle followed by a brief description of our sensor design and fabrication. Our first prototype without wireless has been tested in lab-simulation bench. We obtain a simulation and measurement results have good linearity between micro-inductor radius variation and oscillation frequency. In future work will be to optimize the fabrication technology and the design to reach a better resolution, also a radio frequency integrated circuit (RFIC) and antenna will be designed preferably embedded in the contact lens so that inductance value transfers to frequency value via LC oscillator circuit and transmits intraocular pressure sensing signal by wireless telemetry system.
引用
收藏
页码:1644 / 1647
页数:4
相关论文
共 50 条
[31]   Prototype of a Nanostructured Sensing Contact Lens for Noninvasive Intraocular Pressure Monitoring [J].
Sanchez, Irene ;
Laukhin, Vladimir ;
Moya, Ana ;
Martin, Raul ;
Ussa, Fernando ;
Laukhina, Elena ;
Guimera, Anton ;
Villa, Rosa ;
Rovira, Concepcio ;
Aguilo, Jordi ;
Veciana, Jaume ;
Pastor, Jose C. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (11) :8310-8315
[32]   A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure [J].
Kim, Joohee ;
Park, Jihun ;
Park, Young-Geun ;
Cha, Eunkyung ;
Ku, Minjae ;
An, Hyeon Seok ;
Lee, Kyoung-Pil ;
Huh, Man-Il ;
Kim, Junmo ;
Kim, Taek-Soo ;
Kim, Dai Woo ;
Kim, Hong Kyun ;
Park, Jang-Ung .
NATURE BIOMEDICAL ENGINEERING, 2021, 5 (07) :772-782
[33]   Intraocular Pressure Monitoring Smart Contact Lens with High Environmental Stability [J].
Yang, Huan ;
Zhu, Hengtian ;
Liu, Hanwen ;
Mao, Zhengyi ;
Luo, Junxian ;
Zhu, Shugeng ;
Hu, Zizhong ;
Yuan, Songtao ;
Xu, Fei .
ADVANCED FUNCTIONAL MATERIALS, 2024, 34 (34)
[34]   High-sensitivity liquid-metal-based contact lens sensor for continuous intraocular pressure monitoring [J].
An, Hongbin ;
Chen, Liangzhou ;
Liu, Xiaojun ;
Wang, Xiangyang ;
Liu, Yunfeng ;
Wu, Zhigang ;
Zhao, Bin ;
Zhang, Hong .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2021, 31 (03)
[35]   Liquid-alloy-based dual sensing elements contact lens sensor for continuous intraocular pressure monitoring [J].
Wang, Jun ;
Liu, Xiaojun ;
Diao, Kuan ;
Wang, Shuai .
MEASUREMENT, 2025, 240
[36]   Soft Contact Lens With Embedded Moire Patterns-Based Intraocular Pressure Sensors [J].
Ding, Xiaoke ;
Chen, Mingze ;
Liang, Xiaogan ;
Que, Long .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2022, 31 (06) :971-976
[37]   First steps toward noninvasive intraocular pressure monitoring with a sensing contact lens [J].
Leonardi, M ;
Leuenberger, P ;
Bertrand, D ;
Bertsch, A ;
Renaud, P .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (09) :3113-3117
[38]   A contact lens promising for non-invasive continuous intraocular pressure monitoring [J].
Pang, Yu ;
Li, Yuxing ;
Wang, Xuefeng ;
Qi, Chenjie ;
Yang, Yi ;
Ren, Tian-Ling .
RSC ADVANCES, 2019, 9 (09) :5076-5082
[39]   Wireless theranostic smart contact lens for monitoring and control of intraocular pressure in glaucoma [J].
Kim, Tae Yeon ;
Mok, Jee Won ;
Hong, Sang Hoon ;
Jeong, Sang Hoon ;
Choi, Hyunsik ;
Shin, Sangbaie ;
Joo, Choun-Ki ;
Hahn, Sei Kwang .
NATURE COMMUNICATIONS, 2022, 13 (01)
[40]   Notched-ring structured microfluidic contact lens for intraocular pressure monitoring [J].
Yang, Wentuo ;
Zhang, Xiaoshuang ;
Wang, Yan ;
Fan, Qian ;
Zhang, Shuaihua ;
Chen, Yongqi ;
Shen, Xiaotian ;
Xie, Mengying ;
Duan, Xuexin .
APPLIED PHYSICS LETTERS, 2021, 119 (19)