Design and Fabricate a Contact Lens Sensor with a Micro-Inductor Embedded for Intraocular Pressure Monitoring

被引:0
作者
Tseng, Chien-Kai [1 ]
Huang, Yu-Chieh [1 ]
Tsai, Shang-Wei [1 ]
Yeh, Guan-Ting [1 ]
Chang, Chung-Hao [1 ]
Chiou, Jin-Chern [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Elect Engn, Hsinchu 30010, Taiwan
来源
2012 IEEE SENSORS PROCEEDINGS | 2012年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new type of micro-inductor sensor for intraocular pressure (IOP) measurement on soft contact lens substructure. The sensor was designed and fabricated by using MEMS fabrication technologies. The contact lens is for wearing on a cornea such that a curvature of the contact lens corresponds substantially to that of the cornea, and is preferably made of Hydroxyethylmethacrylate (HEMA) by cast-molding method of soft contact lens for high oxygen permeability and comfortable long-duration wearing. In this paper, we discuss a contact lens with micro-inductor measurement principle followed by a brief description of our sensor design and fabrication. Our first prototype without wireless has been tested in lab-simulation bench. We obtain a simulation and measurement results have good linearity between micro-inductor radius variation and oscillation frequency. In future work will be to optimize the fabrication technology and the design to reach a better resolution, also a radio frequency integrated circuit (RFIC) and antenna will be designed preferably embedded in the contact lens so that inductance value transfers to frequency value via LC oscillator circuit and transmits intraocular pressure sensing signal by wireless telemetry system.
引用
收藏
页码:1644 / 1647
页数:4
相关论文
共 50 条
[21]   Contact Lens Sensor with Anti-jamming Capability and High Sensitivity for Intraocular Pressure Monitoring [J].
Ren, Xueyang ;
Zhou, Yunfan ;
Lu, Fangzhou ;
Zhai, Leili ;
Wu, Hao ;
Chen, Zhongda ;
Wang, Changxian ;
Zhu, Xuefei ;
Xie, Yandong ;
Cai, Pingqiang ;
Xu, Juan ;
Tang, Xianglong ;
Li, Jianqing ;
Yao, Jin ;
Jiang, Qin ;
Hu, Benhui .
ACS SENSORS, 2023, 8 (07) :2691-2701
[22]   Non-invasive Intraocular pressure monitoring with contact lens [J].
Campigotto, Angelica ;
Leahy, Stephane ;
Zhao, Guowei ;
Campbell, Robert J. ;
Lai, Yongjun .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (09) :1324-1328
[23]   A contact lens with embedded sensor for monitoring tear glucose level [J].
Yao, Huanfen ;
Shum, Angela J. ;
Cowan, Melissa ;
Laehdesmaeki, Ilkka ;
Parviz, Babak A. .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (07) :3290-3296
[24]   An Ultrasensitive Contact Lens Sensor Based On Self-Assembly Graphene For Continuous Intraocular Pressure Monitoring [J].
Liu, Zhiduo ;
Wang, Gang ;
Ye, Chen ;
Sun, Hongyan ;
Pei, Weihua ;
Wei, Chunrong ;
Dai, Wen ;
Dou, Zhiqiang ;
Sun, Qingyu ;
Lin, Cheng-Te ;
Wang, Yijun ;
Chen, Hongda ;
Shen, Guozhen .
ADVANCED FUNCTIONAL MATERIALS, 2021, 31 (29)
[25]   Continuous intraocular pressure monitoring in patients with obstructive sleep apnea syndrome using a contact lens sensor [J].
Carnero, Elena ;
Bragard, Jean ;
Urrestarazu, Elena ;
Rivas, Estefania ;
Polo, Vicente ;
Manuel Larrosa, Jose ;
Anton, Vanesa ;
Pelaez, Antonio ;
Moreno-Montanes, Javier .
PLOS ONE, 2020, 15 (03)
[26]   Continuous 24 hour intraocular pressure monitoring for glaucoma with a contact lens sensor - time for a paradigm change [J].
Mansouri, Kaweh ;
Weinreb, Robert N. .
SWISS MEDICAL WEEKLY, 2012, 142
[27]   A Novel Contact Lens Sensor System for Continuous Intraocular Pressure Monitoring: Evaluation of Accuracy in Human Eyes [J].
Wei, Yifan ;
Zhang, Yuning ;
Chen, Zidong ;
Chong, Jones Iok-Tong ;
Lee, Christopher Ching Hymn ;
Karunaratne, Isuru Kaweendra ;
Zhang, Xinyi ;
Deng, Mingjie ;
Yang, Yangfan ;
Lam, David C. C. ;
Yu, Minbin .
OPHTHALMOLOGY SCIENCE, 2025, 5 (05)
[28]   Wearable dual-element intraocular pressure contact lens sensor [J].
Karunaratne, I. K. ;
Lee, Ching Hymn Christopher ;
Or, Ping Wai ;
Wei, Yifan ;
Chong, Iok Tong ;
Yang, Yangfan ;
Yu, Minbin ;
Lam, D. C. C. .
SENSORS AND ACTUATORS A-PHYSICAL, 2021, 321
[29]   Assessment of the Triggerfish™ contact lens sensor for measurement of intraocular pressure variations [J].
Sunaric-Megevand, Gordana ;
Leuenberger, Peter ;
Preussner, Paul-Rolf .
ACTA OPHTHALMOLOGICA, 2014, 92 (05) :E414-E415
[30]   A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure [J].
Joohee Kim ;
Jihun Park ;
Young-Geun Park ;
Eunkyung Cha ;
Minjae Ku ;
Hyeon Seok An ;
Kyoung-Pil Lee ;
Man-Il Huh ;
Junmo Kim ;
Taek-Soo Kim ;
Dai Woo Kim ;
Hong Kyun Kim ;
Jang-Ung Park .
Nature Biomedical Engineering, 2021, 5 :772-782