Design and Fabricate a Contact Lens Sensor with a Micro-Inductor Embedded for Intraocular Pressure Monitoring

被引:0
作者
Tseng, Chien-Kai [1 ]
Huang, Yu-Chieh [1 ]
Tsai, Shang-Wei [1 ]
Yeh, Guan-Ting [1 ]
Chang, Chung-Hao [1 ]
Chiou, Jin-Chern [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Elect Engn, Hsinchu 30010, Taiwan
来源
2012 IEEE SENSORS PROCEEDINGS | 2012年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new type of micro-inductor sensor for intraocular pressure (IOP) measurement on soft contact lens substructure. The sensor was designed and fabricated by using MEMS fabrication technologies. The contact lens is for wearing on a cornea such that a curvature of the contact lens corresponds substantially to that of the cornea, and is preferably made of Hydroxyethylmethacrylate (HEMA) by cast-molding method of soft contact lens for high oxygen permeability and comfortable long-duration wearing. In this paper, we discuss a contact lens with micro-inductor measurement principle followed by a brief description of our sensor design and fabrication. Our first prototype without wireless has been tested in lab-simulation bench. We obtain a simulation and measurement results have good linearity between micro-inductor radius variation and oscillation frequency. In future work will be to optimize the fabrication technology and the design to reach a better resolution, also a radio frequency integrated circuit (RFIC) and antenna will be designed preferably embedded in the contact lens so that inductance value transfers to frequency value via LC oscillator circuit and transmits intraocular pressure sensing signal by wireless telemetry system.
引用
收藏
页码:1644 / 1647
页数:4
相关论文
共 50 条
  • [21] Contact Lens Sensor with Anti-jamming Capability and High Sensitivity for Intraocular Pressure Monitoring
    Ren, Xueyang
    Zhou, Yunfan
    Lu, Fangzhou
    Zhai, Leili
    Wu, Hao
    Chen, Zhongda
    Wang, Changxian
    Zhu, Xuefei
    Xie, Yandong
    Cai, Pingqiang
    Xu, Juan
    Tang, Xianglong
    Li, Jianqing
    Yao, Jin
    Jiang, Qin
    Hu, Benhui
    ACS SENSORS, 2023, 8 (07): : 2691 - 2701
  • [22] Non-invasive Intraocular pressure monitoring with contact lens
    Campigotto, Angelica
    Leahy, Stephane
    Zhao, Guowei
    Campbell, Robert J.
    Lai, Yongjun
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2020, 104 (09) : 1324 - 1328
  • [23] A contact lens with embedded sensor for monitoring tear glucose level
    Yao, Huanfen
    Shum, Angela J.
    Cowan, Melissa
    Laehdesmaeki, Ilkka
    Parviz, Babak A.
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (07) : 3290 - 3296
  • [24] Continuous intraocular pressure monitoring in patients with obstructive sleep apnea syndrome using a contact lens sensor
    Carnero, Elena
    Bragard, Jean
    Urrestarazu, Elena
    Rivas, Estefania
    Polo, Vicente
    Manuel Larrosa, Jose
    Anton, Vanesa
    Pelaez, Antonio
    Moreno-Montanes, Javier
    PLOS ONE, 2020, 15 (03):
  • [25] An Ultrasensitive Contact Lens Sensor Based On Self-Assembly Graphene For Continuous Intraocular Pressure Monitoring
    Liu, Zhiduo
    Wang, Gang
    Ye, Chen
    Sun, Hongyan
    Pei, Weihua
    Wei, Chunrong
    Dai, Wen
    Dou, Zhiqiang
    Sun, Qingyu
    Lin, Cheng-Te
    Wang, Yijun
    Chen, Hongda
    Shen, Guozhen
    ADVANCED FUNCTIONAL MATERIALS, 2021, 31 (29)
  • [26] Continuous 24 hour intraocular pressure monitoring for glaucoma with a contact lens sensor - time for a paradigm change
    Mansouri, Kaweh
    Weinreb, Robert N.
    SWISS MEDICAL WEEKLY, 2012, 142
  • [27] Assessment of the Triggerfish™ contact lens sensor for measurement of intraocular pressure variations
    Sunaric-Megevand, Gordana
    Leuenberger, Peter
    Preussner, Paul-Rolf
    ACTA OPHTHALMOLOGICA, 2014, 92 (05) : E414 - E415
  • [28] Wearable dual-element intraocular pressure contact lens sensor
    Karunaratne, I. K.
    Lee, Ching Hymn Christopher
    Or, Ping Wai
    Wei, Yifan
    Chong, Iok Tong
    Yang, Yangfan
    Yu, Minbin
    Lam, D. C. C.
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 321
  • [29] A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure
    Joohee Kim
    Jihun Park
    Young-Geun Park
    Eunkyung Cha
    Minjae Ku
    Hyeon Seok An
    Kyoung-Pil Lee
    Man-Il Huh
    Junmo Kim
    Taek-Soo Kim
    Dai Woo Kim
    Hong Kyun Kim
    Jang-Ung Park
    Nature Biomedical Engineering, 2021, 5 : 772 - 782
  • [30] Prototype of a Nanostructured Sensing Contact Lens for Noninvasive Intraocular Pressure Monitoring
    Sanchez, Irene
    Laukhin, Vladimir
    Moya, Ana
    Martin, Raul
    Ussa, Fernando
    Laukhina, Elena
    Guimera, Anton
    Villa, Rosa
    Rovira, Concepcio
    Aguilo, Jordi
    Veciana, Jaume
    Pastor, Jose C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (11) : 8310 - 8315