Impact of left atrial appendage occlusion on left atrial function-The LAFIT Watchman study

被引:21
作者
Murtaza, Ghulam [1 ]
Vuddanda, Venkat [2 ]
Akella, Krishna [1 ]
Della Rocca, Domenico G. [3 ]
Sharma, Sharan [1 ]
Li, Ling [4 ]
Kutty, Shelby [4 ]
Turagam, Mohit [5 ]
Kar, Saibal
Holmes, David [6 ]
Lakkireddy, Dhanunjaya [1 ]
机构
[1] Kansas City Heart Rhythm Inst & Res Fdn, 5100 W 110th St Second Floor, Overland Pk, KS 66211 USA
[2] Harvard Med Sch, 25 Shattuck St, Boston, MA 02115 USA
[3] St Davids Med Ctr, Texas Cardiac Arrhythmia Inst, 3000 N Interstate Hwy 35, Austin, TX 78705 USA
[4] Johns Hopkins Med Ctr, Div Pediat Cardiol, 600 N Wolfe St, Baltimore, MD 21205 USA
[5] Mt Sinai Hosp, 1468 Madison Ave, New York, NY 10029 USA
[6] Mayo Clin, Rochester, MN USA
关键词
Watchman device; Left atrial appendage; Speckle tracking echocardiography; Strain analysis; SPECKLE TRACKING; FIBRILLATION; ECHOCARDIOGRAPHY; CLOSURE;
D O I
10.1007/s10840-019-00674-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Left atrial (LA) strain and strain rate (SR) analysis by two-dimensional speckle tracking echocardiography is a novel way of LA function assessment. From prior study, we know that LA appendage closure with LARIAT appears to improve LA function. Objective The purpose of this study was to assess the impact of LAA closure via Watchman device on LA function via strain and volumetric analyses using two-dimensional speckle tracking echocardiography (2D-STE). Methods Twenty-five patients who underwent Watchman device implantation (WDI) were included. LA function parameters (volumetric, strain indices) were calculated from apical four chamber views with the reference point set at QRS using 2D-STE before and after WDI. LA expansion index, strain and strain rate during ventricular systole represent LA reservoir function. Passive emptying fraction, strain and strain rate during early ventricular diastole represent LA conduit function. Results Mean age was 76 +/- 6.9 years with 60% males. There was significant improvement in conduit function (LA passive emptying fraction; post 28.6 (21.9-35.9) vs pre 21.0 (13.8-34.7),p = 0.032), reservoir function (LA expansion index; post 75.3 (52.3-98.0) vs pre 58.1 (37.8-85.2),p = 0.026), and booster function (LA active emptying fraction; post 13.3 (9.7-29.9) vs pre 12.6 (8.8-25.5),p = 0.04) by volumetric indices. No significant improvement was noted with strain indices in conduit function (SRe; post - 0.56 (0.43-0.93) vs pre - 0.58 (0.46-0.87);p = 0.518) and reservoir function (SRs; post + 0.58 (0.28-0.40) vs pre + 0.52 (0.35-0.86);p = 0.851). Conclusions WDI resulted in discrepancy of volumetric and strain indices in LA function assessment.
引用
收藏
页码:163 / 167
页数:5
相关论文
共 21 条
[1]   Assessment of left atrial deformation properties by speckle tracking in patients with systolic heart failure [J].
Ahmed, Mahmoud K. ;
Soliman, Mahmoud A. ;
Reda, Ahmed A. ;
Abd El-Ghani, Rania S. .
EGYPTIAN HEART JOURNAL, 2015, 67 (03) :199-208
[2]   Left Atrial Appendage Closure - The WATCHMAN Device [J].
Akinapelli, Abhilash ;
Bansal, Ojas ;
Chen, Jack P. ;
Pflugfelder, Alex ;
Gordon, Nicole ;
Stein, Kenneth ;
Huibregtse, Barbara ;
Hou, Dongming .
CURRENT CARDIOLOGY REVIEWS, 2015, 11 (04) :334-340
[3]   Left atrial appendage: structure, function, and role in thromboembolism [J].
Al-Saady, NM ;
Obel, OA ;
Camm, AJ .
HEART, 1999, 82 (05) :547-554
[4]  
Alessandri N, 2003, Eur Rev Med Pharmacol Sci, V7, P65
[5]  
[Anonymous], 2016, INT J CARDIOL HEART
[6]   Percutaneous Left Atrial Appendage Closure: Current Devices and Clinical Outcomes [J].
Asmarats, Lluis ;
Rodes-Cabau, Josep .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (11)
[7]   Oral anticoagulant use for stroke prevention in atrial fibrillation patients with difficult scenarios [J].
Chang, Ting-Yung ;
Liao, Jo-Nan ;
Chao, Tze-Fan ;
Vicera, Jennifer Jeanne ;
Lin, Chin-Yu ;
Tuan, Ta-Chuan ;
Lin, Yenn-Jiang ;
Chang, Shih-Lin ;
Lo, Li-Wei ;
Hu, Yu-Feng ;
Chung, Fa-Po ;
Chen, Shih-Ann .
IJC HEART & VASCULATURE, 2018, 20 :56-62
[8]   Percutaneous left atrial appendage closure improves left atrial mechanical function through Frank-Starling mechanism [J].
Coisne, Augustin ;
Pilato, Rosario ;
Brigadeau, Francois ;
Klug, Didier ;
Marquie, Christelle ;
Souissi, Zouheir ;
Richardson, Marjorie ;
Mouton, Stephanie ;
Polge, Anne-Sophie ;
Lancellotti, Patrizio ;
Lacroix, Dominique ;
Montaigne, David .
HEART RHYTHM, 2017, 14 (05) :710-716
[9]   Mechanical function of the left atrium is improved with epicardial ligation of the left atrial appendage: Insights from the LAFIT-LARIAT Registry [J].
Dar, Tawseef ;
Afzal, Muhammad R. ;
Yarlagadda, Bharath ;
Kutty, Shelby ;
Shang, Quanliang ;
Gunda, Sampath ;
Samanta, Anweshan ;
Thummaluru, Jahnavi ;
Arukala, Kedareeshwar S. ;
Kanmanthareddy, Arun ;
Reddy, Madhu ;
Atkins, Donita ;
Bommana, Sudharani ;
Dawn, Buddhadeb ;
Lakkireddy, Dhanunjaya .
HEART RHYTHM, 2018, 15 (07) :955-959
[10]   Role of speckle tracking echocardiography in detecting early left atrial dysfunction in hypertensive patients [J].
Hennawy, Bassam ;
El Kilany, Wael ;
Galal, Haitham ;
Mamdouh, Ahmed .
EGYPTIAN HEART JOURNAL, 2018, 70 (03) :217-223