A Comparative Study on the Performances of Flat Plate and Evacuated Tube Collectors Deployable in Domestic Solar Water Heating Systems in Different Climate Areas

被引:30
|
作者
Greco, Adriana [1 ]
Gundabattini, Edison [2 ]
Gnanaraj, Darius S. [3 ]
Masselli, Claudia [4 ]
机构
[1] Univ Naples Federico II, DII, P Le Tecchio 80, I-80125 Naples, Italy
[2] Vellore Inst Technol VIT, Dept Thermal & Energy Engn, Vellore 632014, Tamil Nadu, India
[3] Vellore Inst Technol VIT, Dept Design & Automat, Vellore 632014, Tamil Nadu, India
[4] Univ Salerno, DIIn, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
关键词
flat-plate collector; evacuated-tube collectors; solar energy; solar water heating; climate areas; TRNSYS; 16; software; SMOOTH HORIZONTAL TUBE; SEASONAL STORAGE; WORKING;
D O I
10.3390/cli8060078
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Using TRNSYS software, a comparison of the energy performances of flat-plate collectors (FPCs) and evacuated-tube collectors (ETCs) in domestic solar water heating systems located in different climate areas was carried out in order to ascertain solar energy utilization. Investigations were carried out on single FPCs and ETCs and also for strings of four panels connected in series. Tests were conducted using simulations for water as heat transfer fluid with a fixed fluid flow rate and varying the temperature of the collector's returning fluid. The maximum power peak decreases with the increase in the inlet temperature of the fluid to the collector in the FPC. The maximum outlet temperature of the FPC is higher than the ETC, most of the time. The evacuated-tube collector performs better only in cold climate areas. Simulations suggest that the use of the FPC is strongly discouraged in cold climatic areas due to thermal losses, whereas the ETC works well with reduced dispersion of heat. In warm seasons, on the contrary, the FPC takes advantage of the high environmental temperature which heats the fluid. The maximum yearly outlet temperature and useful power peak predicted in different climatic areas were investigated by varying the temperature of the fluid inlet fed to the two strings of four FPCs and ETCs. In all cases, the outlet temperature is higher in the ETC technology.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions
    Zambolin, E.
    Del Col, D.
    SOLAR ENERGY, 2010, 84 (08) : 1382 - 1396
  • [32] Simplified procedure for determining the heat performances of flat solar water-heating collectors
    Avezova N.R.
    Applied Solar Energy (English translation of Geliotekhnika), 2010, 46 (03): : 172 - 174
  • [33] A study of the effects of water capacity on the thermal performance of water-in-glass evacuated tube solar collectors applied to space heating
    Yu, Guoqing
    Xiong, Le
    Chen, Hengtao
    Du, Chengjun
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (07) : 795 - 804
  • [34] Improving solar water heating performance and reducing emissions by evacuated tube collectors with preheating units: Iraq as a case study☆
    Khadom, Anees A.
    Mahood, Hameed B.
    Mahmmod, Adiba A.
    Hassan, Qusay
    Kazem, Hussein A.
    APPLIED THERMAL ENGINEERING, 2025, 265
  • [35] An examination of evacuated tube collectors in comparison to direct flow and heat pipe for the purpose of solar water heating
    Palanivel, Vijayakumar
    Munimathan, Arunkumar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 8686 - 8702
  • [36] A Comparative Thermal Performance Assessment of Various Solar Collectors for Domestic Water Heating
    Kalair, Ali Raza
    Seyedmahmoudian, Mehdi
    Saleem, Muhammad Shoaib
    Abas, Naeem
    Rauf, Shoaib
    Stojcevski, Alex
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2022, 2022
  • [37] Effect of Glazing Materials on the Performance of Solar Flat Plate Collectors for Water Heating Applications
    Dondapati, Raja Sekhar
    Agarwal, Rahul
    Saini, Vishnu
    Vyas, Gaurav
    Thakur, Jitendra
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (14) : 27680 - 27689
  • [38] Nonstationarity of the Efficiency Coefficient and Heating Temperatures of Water in Flat-Plate Solar Collectors
    Klychev S.I.
    Bakhramov S.A.
    Harchenko V.V.
    Applied Solar Energy, 2018, 54 (4) : 287 - 292
  • [39] A comparison between flat-plate and evacuated tube solar collectors in terms of energy and exergy analysis by using nanofluid
    Eltaweel, Mahmoud
    Abdel-Rehim, Ahmed A.
    Attia, Ahmed A. A.
    APPLIED THERMAL ENGINEERING, 2021, 186
  • [40] The sizes of Flat Plate and Evacuated Tube Collectors with Heat Pipe area as a function of the share of solar system in the heat demand
    Olek, Malgorzata
    Olczak, Piotr
    Kryzia, Dominik
    1ST INTERNATIONAL CONFERENCE ON THE SUSTAINABLE ENERGY AND ENVIRONMENT DEVELOPMENT (SEED 2016), 2016, 10