A Comparative Study on the Performances of Flat Plate and Evacuated Tube Collectors Deployable in Domestic Solar Water Heating Systems in Different Climate Areas

被引:30
|
作者
Greco, Adriana [1 ]
Gundabattini, Edison [2 ]
Gnanaraj, Darius S. [3 ]
Masselli, Claudia [4 ]
机构
[1] Univ Naples Federico II, DII, P Le Tecchio 80, I-80125 Naples, Italy
[2] Vellore Inst Technol VIT, Dept Thermal & Energy Engn, Vellore 632014, Tamil Nadu, India
[3] Vellore Inst Technol VIT, Dept Design & Automat, Vellore 632014, Tamil Nadu, India
[4] Univ Salerno, DIIn, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
关键词
flat-plate collector; evacuated-tube collectors; solar energy; solar water heating; climate areas; TRNSYS; 16; software; SMOOTH HORIZONTAL TUBE; SEASONAL STORAGE; WORKING;
D O I
10.3390/cli8060078
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Using TRNSYS software, a comparison of the energy performances of flat-plate collectors (FPCs) and evacuated-tube collectors (ETCs) in domestic solar water heating systems located in different climate areas was carried out in order to ascertain solar energy utilization. Investigations were carried out on single FPCs and ETCs and also for strings of four panels connected in series. Tests were conducted using simulations for water as heat transfer fluid with a fixed fluid flow rate and varying the temperature of the collector's returning fluid. The maximum power peak decreases with the increase in the inlet temperature of the fluid to the collector in the FPC. The maximum outlet temperature of the FPC is higher than the ETC, most of the time. The evacuated-tube collector performs better only in cold climate areas. Simulations suggest that the use of the FPC is strongly discouraged in cold climatic areas due to thermal losses, whereas the ETC works well with reduced dispersion of heat. In warm seasons, on the contrary, the FPC takes advantage of the high environmental temperature which heats the fluid. The maximum yearly outlet temperature and useful power peak predicted in different climatic areas were investigated by varying the temperature of the fluid inlet fed to the two strings of four FPCs and ETCs. In all cases, the outlet temperature is higher in the ETC technology.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Thermal performance enhancement of flat-plate and evacuated tube solar collectors using nanofluid: A review
    Muhammad, Mahmud Jamil
    Muhammad, Isa Adamu
    Sidik, Nor Azwadi Che
    Yazid, Muhammad Noor Afiq Witri Muhammad
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 76 : 6 - 15
  • [22] Feasibility of active solar water heating systems with evacuated tube collector at different operational water temperatures
    Mazarron, Fernando R.
    Javier Porras-Prieto, Carlos
    Luis Garcia, Jose
    Maria Benavente, Rosa
    ENERGY CONVERSION AND MANAGEMENT, 2016, 113 : 16 - 26
  • [23] DESIGN CONSIDERATIONS FOR RESIDENTIAL SOLAR HEATING AND COOLING SYSTEMS UTILIZING EVACUATED TUBE SOLAR COLLECTORS.
    Ward, Dan S.
    Ward, John C.
    1977, 1
  • [24] COMPARISON OF THE EFFECTIVE SYSTEM PERFORMANCE OF FLAT PLATE AND EVACUATED TUBE COLLECTORS USED FOR DISTRICT HEATING PURPOSES.
    Zinko, Heimo
    Holst, Per
    Perers, Bengt
    Eriksson, Leif
    Journal of Solar Energy Research, 1984, 2 (01): : 17 - 30
  • [25] Comparative Studies on the Efficiency of Solar Flat-plate Collector and Evacuated Tube Collector
    Yan, Huilei
    Zhang, Hua
    Shao, Qiuping
    ADVANCES IN ENERGY SCIENCE AND TECHNOLOGY, PTS 1-4, 2013, 291-294 : 3 - 8
  • [26] Comparative field experimental investigations of different flat plate solar collectors
    Chen, Guangming
    Doroshenko, Alexander
    Koltun, Paul
    Shestopalov, Kostyantyn
    SOLAR ENERGY, 2015, 115 : 577 - 588
  • [27] Comparative Study of Different Tube Geometries of Evacuated Tube Solar Collector
    Sonowal, Juri
    Bhowmik, Mrinal
    Muthukumar, P.
    Anandalakshmi, R.
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2023, 145 (05):
  • [28] ANNUAL TRANSIENT SIMULATIONS AND EXPERIMENTAL INVESTIGATION OF A HYBRID FLAT PLATE AND EVACUATED TUBE COLLECTORS ARRAY IN SUBTROPICAL CLIMATE
    Kousar, Rubeena
    Ali, Muzaffar
    THERMAL SCIENCE, 2020, 24 (02): : 1435 - 1443
  • [29] Optimal slope angle selection of an evacuated tube collector for domestic solar water heating
    Coetzee, Rigardt Alfred Maarten
    Mwesigye, Aggrey
    Huan, Zhongjie
    JOURNAL OF ENERGY IN SOUTHERN AFRICA, 2017, 28 (01) : 104 - 119
  • [30] Effect of dimples on solar concrete plate collectors and its comparison with other domestic water heating systems
    Sable, Ajinkya