A Comparative Study on the Performances of Flat Plate and Evacuated Tube Collectors Deployable in Domestic Solar Water Heating Systems in Different Climate Areas

被引:33
作者
Greco, Adriana [1 ]
Gundabattini, Edison [2 ]
Gnanaraj, Darius S. [3 ]
Masselli, Claudia [4 ]
机构
[1] Univ Naples Federico II, DII, P Le Tecchio 80, I-80125 Naples, Italy
[2] Vellore Inst Technol VIT, Dept Thermal & Energy Engn, Vellore 632014, Tamil Nadu, India
[3] Vellore Inst Technol VIT, Dept Design & Automat, Vellore 632014, Tamil Nadu, India
[4] Univ Salerno, DIIn, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
关键词
flat-plate collector; evacuated-tube collectors; solar energy; solar water heating; climate areas; TRNSYS; 16; software; SMOOTH HORIZONTAL TUBE; SEASONAL STORAGE; WORKING;
D O I
10.3390/cli8060078
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Using TRNSYS software, a comparison of the energy performances of flat-plate collectors (FPCs) and evacuated-tube collectors (ETCs) in domestic solar water heating systems located in different climate areas was carried out in order to ascertain solar energy utilization. Investigations were carried out on single FPCs and ETCs and also for strings of four panels connected in series. Tests were conducted using simulations for water as heat transfer fluid with a fixed fluid flow rate and varying the temperature of the collector's returning fluid. The maximum power peak decreases with the increase in the inlet temperature of the fluid to the collector in the FPC. The maximum outlet temperature of the FPC is higher than the ETC, most of the time. The evacuated-tube collector performs better only in cold climate areas. Simulations suggest that the use of the FPC is strongly discouraged in cold climatic areas due to thermal losses, whereas the ETC works well with reduced dispersion of heat. In warm seasons, on the contrary, the FPC takes advantage of the high environmental temperature which heats the fluid. The maximum yearly outlet temperature and useful power peak predicted in different climatic areas were investigated by varying the temperature of the fluid inlet fed to the two strings of four FPCs and ETCs. In all cases, the outlet temperature is higher in the ETC technology.
引用
收藏
页数:21
相关论文
共 42 条
[1]   Per capita income, trade openness, urbanization, energy consumption, and CO2 emissions: an empirical study on the SAARC Region [J].
Afridi, Muhammad Asim ;
Kehelwalatenna, Sampath ;
Naseem, Imran ;
Tahir, Muhammad .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (29) :29978-29990
[2]   Global warming: review on driving forces and mitigation [J].
Al-Ghussain, Loiy .
ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2019, 38 (01) :13-21
[3]  
Anthony M.D., 1997, ASHRAE T, V103, P446
[4]   The use of barocaloric effect for energy saving in a domestic refrigerator with ethylene-glycol based nanofluids: A numerical analysis and a comparison with a vapor compression cooler [J].
Aprea, C. ;
Greco, A. ;
Maiorino, A. ;
Masselli, C. .
ENERGY, 2020, 190
[5]   The employment of caloric-effect materials for solid-state heat pumping [J].
Aprea, C. ;
Greco, A. ;
Maiorino, A. ;
Masselli, C. .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 109 :1-11
[6]   A rotary permanent magnet magnetic refrigerator based on AMR cycle [J].
Aprea, C. ;
Cardillo, G. ;
Greco, A. ;
Maiorino, A. ;
Masselli, C. .
APPLIED THERMAL ENGINEERING, 2016, 101 :699-703
[7]   The environmental impact of solid-state materials working in an active caloric refrigerator compared to a vapor compression cooler [J].
Aprea, Ciro ;
Greco, Adriana ;
Maiorino, Angelo ;
Masselli, Claudia .
INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2018, 36 (04) :1155-1162
[8]  
Aprea C, 2017, INT J HEAT TECHNOL, V35, pS383, DOI 10.18280/ijht.35Sp0152
[9]   HFO1234yf as a Drop-in Replacement for R134a in Domestic Refrigerators: A Life Cycle Climate Performance Analysis [J].
Aprea, Ciro ;
Greco, Adriana ;
Maiorino, Angelo ;
Masselli, Claudia ;
Metallo, Antonio .
INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2016, 34 (Special Issue 2) :S212-S218
[10]   Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate [J].
Ayompe, L. M. ;
Duffy, A. ;
Mc Keever, M. ;
Conlon, M. ;
McCormack, S. J. .
ENERGY, 2011, 36 (05) :3370-3378