A Comparative Study on the Performances of Flat Plate and Evacuated Tube Collectors Deployable in Domestic Solar Water Heating Systems in Different Climate Areas

被引:30
|
作者
Greco, Adriana [1 ]
Gundabattini, Edison [2 ]
Gnanaraj, Darius S. [3 ]
Masselli, Claudia [4 ]
机构
[1] Univ Naples Federico II, DII, P Le Tecchio 80, I-80125 Naples, Italy
[2] Vellore Inst Technol VIT, Dept Thermal & Energy Engn, Vellore 632014, Tamil Nadu, India
[3] Vellore Inst Technol VIT, Dept Design & Automat, Vellore 632014, Tamil Nadu, India
[4] Univ Salerno, DIIn, Via Giovanni Paolo II 132, I-84084 Fisciano, SA, Italy
关键词
flat-plate collector; evacuated-tube collectors; solar energy; solar water heating; climate areas; TRNSYS; 16; software; SMOOTH HORIZONTAL TUBE; SEASONAL STORAGE; WORKING;
D O I
10.3390/cli8060078
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Using TRNSYS software, a comparison of the energy performances of flat-plate collectors (FPCs) and evacuated-tube collectors (ETCs) in domestic solar water heating systems located in different climate areas was carried out in order to ascertain solar energy utilization. Investigations were carried out on single FPCs and ETCs and also for strings of four panels connected in series. Tests were conducted using simulations for water as heat transfer fluid with a fixed fluid flow rate and varying the temperature of the collector's returning fluid. The maximum power peak decreases with the increase in the inlet temperature of the fluid to the collector in the FPC. The maximum outlet temperature of the FPC is higher than the ETC, most of the time. The evacuated-tube collector performs better only in cold climate areas. Simulations suggest that the use of the FPC is strongly discouraged in cold climatic areas due to thermal losses, whereas the ETC works well with reduced dispersion of heat. In warm seasons, on the contrary, the FPC takes advantage of the high environmental temperature which heats the fluid. The maximum yearly outlet temperature and useful power peak predicted in different climatic areas were investigated by varying the temperature of the fluid inlet fed to the two strings of four FPCs and ETCs. In all cases, the outlet temperature is higher in the ETC technology.
引用
收藏
页数:21
相关论文
共 50 条
  • [1] Comparative field performance study of flat plate and heat pipe evacuated tube collectors (ETCs) for domestic water heating systems in a temperate climate
    Ayompe, L. M.
    Duffy, A.
    Mc Keever, M.
    Conlon, M.
    McCormack, S. J.
    ENERGY, 2011, 36 (05) : 3370 - 3378
  • [2] Comparative Study of Solar Water Heating Systems - Flat Plate Collector (FPC) with Evacuated Tube Collector
    David, Jefferson Stanley
    Viveckraj, Jayaraman
    Sivamani, Seralathan
    Varatharajan, K.
    INTERNATIONAL JOURNAL OF ENGINEERING RESEARCH IN AFRICA, 2016, 26 : 76 - 85
  • [3] Validated TRNSYS model for forced circulation solar water heating systems with flat plate and heat pipe evacuated tube collectors
    Ayompe, L. M.
    Duffy, A.
    McCormack, S. J.
    Conlon, M.
    APPLIED THERMAL ENGINEERING, 2011, 31 (8-9) : 1536 - 1542
  • [4] Comparison of the Energy Performance between Flat-plate and Heat Pipe Evacuated Tube Collectors for Solar Water Heating Systems under Mediterranean Climate Conditions
    Maraj, Altin
    Londo, Andonaq
    Firat, Coskun
    Gebremedhin, Alemayehu
    JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2019, 7 (01): : 87 - 100
  • [5] Experimental Comparison of Flat Plate and Evacuated Tube Solar Thermal Collectors for Domestic Hot Water Preparation in Education Facilities
    Moldovan, Macedon
    Visa, Ion
    Burduhos, Bogdan Gabriel
    JOURNAL OF SUSTAINABLE DEVELOPMENT OF ENERGY WATER AND ENVIRONMENT SYSTEMS-JSDEWES, 2020, 8 (02): : 293 - 303
  • [6] Detailed comparison of the performance of flat-plate and vacuum tube solar collectors for domestic hot water heating
    Yohanis, Y. G.
    Popel, O. S.
    Frid, S. E.
    Kolomiets, Yu. G.
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2012, 31 (05) : 347 - 364
  • [7] EXPERIMENTAL DAILY ENERGY PERFORMANCE OF FLAT PLATE AND EVACUATED TUBE SOLAR COLLECTORS
    Zambolin, Enrico
    Del Col, Davide
    Padovan, Andrea
    ES2009: PROCEEDINGS OF THE ASME 3RD INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, VOL 2, 2009, : 853 - 862
  • [8] Economic feasibility of flat plate vs evacuated tube solar collectors in a combisystem
    Najera-Trejo, Mario
    Martin-Domiguez, Ignacio R.
    Escobedo-Bretado, Jorge A.
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2015), 2016, 91 : 477 - 485
  • [9] Proof of guaranteed solar yields in solar thermal plants with flat plate and evacuated tube collectors
    Karandashev, Artem
    Eberhardt, Kay
    Gaspar, Paul
    Meißner, Rolf
    Euroheat and Power/Fernwarme International, 2022, 51 (7-8): : 24 - 31
  • [10] Design of a solar-driven cogeneration system using flat plate collectors and evacuated tube collectors
    Bellos, Evangelos
    Tzivanidis, Christos
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (11) : 5841 - 5851