Comparison of Transcranial Color-Coded Real-time Sonography and Contrast-Enhanced Color-Coded Sonography for Detection and Characterization of Intracranial Arteriovenous Malformations

被引:4
作者
Wang, Li-Shu [1 ]
He, Wen [1 ]
Wang, Hao [2 ]
Zhao, Yuan-Li [2 ]
Tian, Feng-Lan [1 ]
Ning, Bin [1 ]
Gao, Jing [3 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Dept Ultrasound, Beijing 100050, Peoples R China
[2] Capital Med Univ, Beijing Tiantan Hosp, Dept Neurosurg, Beijing 100050, Peoples R China
[3] New York Presbyterian Hosp, Weill Cornell Med Coll, Dept Radiol, New York, NY USA
关键词
contrast-enhanced sonography; intracranial arteriovenous malformation; transcranial color-coded sonography; vascular ultrasound; MAGNETIC-RESONANCE ANGIOGRAPHY; SPIRAL CT ANGIOGRAPHY; DUPLEX SONOGRAPHY; STROKE PATIENTS; LIMITATIONS;
D O I
10.7863/ultra.33.2.273
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-To compare the diagnostic value of transcranial color-coded real-time sonography and contrast-enhanced color-coded sonography in detection and characterization of intracranial arteriovenous malformations. Methods-Thirty-one patients highly suspected to have an intracranial arteriovenous malformation were imaged with real-time and contrast-enhanced sonography. With digital subtraction angiography as the reference standard, the ability to detect the malformations and accurately determine their size and location was compared between the two imaging techniques. Results-One cavernous hemangioma and 30 intracranial arteriovenous malformations were imaged with real-time and contrast-enhanced sonography, which were confirmed by angiography. The detectability of contrast-enhanced sonography, especially for optimizing visualization of malformations located in the frontal, parietal, and occipital lobes, was higher than that of real-time sonography, although the overall number of malformations was too small to demonstrate significance. The sizes of the malformations (6 in the frontal lobe, 1 in the parietal lobe, and 1 in the occipital lobe) were underestimated by real-time sonography compared to angiography, whereas there was agreement in the sizes between contrast-enhanced sonography and angiography. The detection rates for the 30 arteriovenous malformations on contrast-enhanced and real-time sonography were 96.7% (29 of 30) and 70.0% (21 of 30), respectively (P = .008). Moreover, contrast-enhanced sonography was significantly superior to real-time sonography for detection of feeding arteries (59.5% [22 of 37] versus 83.7% [31 of 37]; P = .004). Although the feeding arteries showed increased peak systolic and end-diastolic velocities after contrast agent injection, there were no statistically significant differences in the velocities before and after injection. Conclusions-Transcranial contrast-enhanced color-coded sonography is superior to color-coded real-time sonography for detection of intracranial arteriovenous malformations, particularly for lesions located in the frontal, parietal, and occipital lobes of the brain.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 17 条
[1]   Evaluation of arteriovenous malformations (AVMs) with transcranial color-coded duplex sonography - Does the location of an AVM influence its sonographic detection? [J].
Bartels, E .
JOURNAL OF ULTRASOUND IN MEDICINE, 2005, 24 (11) :1511-1517
[2]   TRANSCRANIAL COLOR-CODED DUPLEX SONOGRAPHY, MAGNETIC-RESONANCE ANGIOGRAPHY, AND COMPUTED-TOMOGRAPHY ANGIOGRAPHY - METHODS, APPLICATIONS, ADVANTAGES, AND LIMITATIONS [J].
BAUMGARTNER, RW ;
MATTLE, HP ;
AASLID, R .
JOURNAL OF CLINICAL ULTRASOUND, 1995, 23 (02) :89-111
[3]   TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY IN THE EVALUATION OF INTRACRANIAL NEOPLASMS AND ARTERIOVENOUS-MALFORMATIONS [J].
BECKER, G ;
PEREZ, J ;
KRONE, A ;
DEMUTH, K ;
LINDNER, A ;
HOFMANN, E ;
WINKLER, J ;
BOGDAHN, U ;
SMITH, RR .
NEUROSURGERY, 1992, 31 (03) :420-428
[4]  
Bin JP, 1997, CHIN J ULTRASOUND ME, V13, P40
[5]   SonoVue® (BR1), a new long-acting echocontrast agent, improves transcranial colour-coded duplex ultrasonic imaging [J].
Droste, DW ;
Llull, JB ;
Pezzoli, C ;
Bogdahn, U ;
Kaps, M .
CEREBROVASCULAR DISEASES, 2002, 14 (01) :27-32
[6]   Stereotactic Radiosurgery for Pediatric Arteriovenous Malformations [J].
Foy, Andrew B. ;
Wetjen, Nicholas ;
Pollock, Bruce E. .
NEUROSURGERY CLINICS OF NORTH AMERICA, 2010, 21 (03) :457-+
[7]  
Gahn G, 2000, AM J NEURORADIOL, V21, P509
[8]   MAGNETIC-RESONANCE ANGIOGRAPHY COMPARED TO INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY IN PATIENTS WITH SUBARACHNOID HEMORRHAGE [J].
GOULIAMOS, A ;
GOTSIS, E ;
VLAHOS, L ;
SAMARA, C ;
KAPSALAKI, E ;
ROLOGIS, D ;
KAPSALAKIS, Z ;
PAPAVASILIOU, C .
NEURORADIOLOGY, 1992, 35 (01) :46-49
[9]   Sensitivity of CT angiography, T2-weighted MRI, and magnetic resonance angiography in detecting cerebral arteriovenous malformations and associated aneurysms [J].
Gross, Bradley A. ;
Frerichs, Kai U. ;
Du, Rose .
JOURNAL OF CLINICAL NEUROSCIENCE, 2012, 19 (08) :1093-1095
[10]  
HEISERMAN JE, 1994, AM J NEURORADIOL, V15, P1401