Quantitative characterization of electron detectors for transmission electron microscopy

被引:156
作者
Ruskin, Adrian I. [1 ]
Yu, Zhiheng [2 ]
Grigorieff, Nikolaus [1 ,2 ]
机构
[1] Brandeis Univ, Rosenstiel Basic Med Sci Res Ctr, Dept Biochem, MS029,415 South St, Waltham, MA 02454 USA
[2] Howard Hughes Med Inst, Janelia Farm Res Campus, Ashburn, VA 20147 USA
基金
美国国家卫生研究院;
关键词
DQE; MTF; Direct electron detector; Transmission electron microscopy; BEAM-INDUCED MOTION; NOISE TRANSFER; CCD CAMERAS; RESOLUTION; CLASSIFICATION; HETEROGENEITY; PERFORMANCE; EFFICIENCY; SIGNAL; EDGE;
D O I
10.1016/j.jsb.2013.10.016
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A new generation of direct electron detectors for transmission electron microscopy (TEM) promises significant improvement over previous detectors in terms of their modulation transfer function (MTF) and detective quantum efficiency (DQE). However, the performance of these new detectors needs to be carefully monitored in order to optimize imaging conditions and check for degradation over time. We have developed an easy-to-use software tool, FindDQE, to measure MTF and DQE of electron detectors using images of a microscope's built-in beam stop. Using this software, we have determined the DQE curves of four direct electron detectors currently available: the Gatan K2 Summit, the FEI Falcon I and II, and the Direct Electron DE-12, under a variety of total dose and dose rate conditions. We have additionally measured the curves for the Gatan US4000 and TVIPS TemCam-F416 scintillator-based cameras. We compare the results from our new method with published curves. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:385 / 393
页数:9
相关论文
共 33 条
[1]   Ribosome structures to near-atomic resolution from thirty thousand cryo-EM particles [J].
Bai, Xiao-chen ;
Fernandez, Israel S. ;
McMullan, Greg ;
Scheres, Sjors H. W. .
ELIFE, 2013, 2
[2]   Practical performance evaluation of a 10k x 10k CCD for electron cryo-microscopy [J].
Bammes, Benjamin E. ;
Rochat, Ryan H. ;
Jakana, Joanita ;
Chiu, Wah .
JOURNAL OF STRUCTURAL BIOLOGY, 2011, 175 (03) :384-393
[3]   Beam-induced motion of vitrified specimen on holey carbon film [J].
Brilot, Axel F. ;
Chen, James Z. ;
Cheng, Anchi ;
Pan, Junhua ;
Harrison, Stephen C. ;
Potter, Clinton S. ;
Carragher, Bridget ;
Henderson, Richard ;
Grigorieff, Nikolaus .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 177 (03) :630-637
[4]   Movies of Ice-Embedded Particles Enhance Resolution in Electron Cryo-Microscopy [J].
Campbell, Melody G. ;
Cheng, Anchi ;
Brilot, Axel F. ;
Moeller, Arne ;
Lyumkis, Dmitry ;
Veesler, David ;
Pan, Junhua ;
Harrison, Stephen C. ;
Potter, Clinton S. ;
Carragher, Bridget ;
Grigorieff, Nikolaus .
STRUCTURE, 2012, 20 (11) :1823-1828
[5]   MRC image processing programs [J].
Crowther, RA ;
Henderson, R ;
Smith, JM .
JOURNAL OF STRUCTURAL BIOLOGY, 1996, 116 (01) :9-16
[6]  
den Broek W.V., 2012, MICROSC MICROANAL OF, V18, P336
[7]   Electronic detectors for electron microscopy [J].
Faruqi, A. R. ;
Henderson, R. .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 2007, 17 (05) :549-555
[8]   Computational separation of conformational heterogeneity using cryo-electron tomography and 3D sub-volume averaging [J].
Frank, Gabriel A. ;
Bartesaghi, Alberto ;
Kuybeda, Oleg ;
Borgnia, Mario J. ;
White, Tommi A. ;
Sapiro, Guillermo ;
Subramaniam, Sriram .
JOURNAL OF STRUCTURAL BIOLOGY, 2012, 178 (02) :165-176
[9]  
Ghadimi R., 2011, MICROSC MICROANAL, V17, P1208
[10]   Near-atomic resolution reconstructions of icosahedral viruses from electron cryo-microscopy [J].
Grigorieff, Nikolaus ;
Harrison, Stephen C. .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 2011, 21 (02) :265-273