Effect of duct aspect ratio on heat transfer and friction in steam-cooled ducts with 60° angled rib turbulators

被引:45
作者
Shui, Linqi [1 ]
Gao, Jianmin [1 ]
Shi, Xiaojun [1 ]
Liu, Jiazeng [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Mfg Syst Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Experiment; Numerical simulation; Heat transfer enhancement; Ribbed duct; Steam-cooling; RECTANGULAR CHANNELS; TRANSFER AUGMENTATION; TURBULENT-FLOW; GAS-TURBINE; CONVECTION; PERFORMANCE; SIMULATION;
D O I
10.1016/j.expthermflusci.2013.04.010
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effect of duct aspect ratio on heat transfer and friction characteristics is investigated experimentally and numerically. Heat transfer experiments as well as pressure drop measurements are carried out to get detailed local heat transfer coefficient distributions and friction factor data for steam-cooled ducts with 60 degrees angled ribs. The test cases are also analyzed numerically by adopting the SSG turbulence model. Four different duct aspect ratios (AR) are studied: AR = 1/4, 1/2, 1/1 and 2/1, the corresponding hydraulic diameter (D) is 32.0 mm, 53.33 mm, 40.0 mm and 53.33 mm, and the rib height-to-hydraulic diameter ratio (e/D) is 0.078, 0.047, 0.0475 and 0.047, respectively. The rib pitch-to-rib height ratio (p/e) is kept 10 for all the ducts. The investigated Re number ranges from 10,000 to 80,000. Both the experimental and numerical results show the similar trend on heat transfer and friction loss, but the prediction values are higher by 3-15% and 2-20%, respectively. The centerline heat transfer coefficient of steam on the ribbed side wall is gradually increased in the fully developed flow region because of the rib angle. The overall heat transfer coefficient is increased with increasing duct aspect ratio (except the duct of AR = 1/1). The averaged heat transfer coefficient ratio of steam is higher by 12-25% than air at the same test conditions. The highest heat transfer enhancement accompanied by the highest friction factor is occurred at AR = 2/1, however, the optimum thermal enhancement factor is found at AR = 1/2. (c) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:123 / 134
页数:12
相关论文
共 25 条
[1]  
Bohn D., 2002, P ASME TURB EXP 2002
[2]   Influence of channel height on heat transfer augmentation in rectangular channels with two opposite rib-roughened walls [J].
Chang, SW ;
Liou, TM ;
Juan, WC .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (13) :2806-2813
[3]   Heat transfer augmentation using a rib-dimple compound cooling technique [J].
Choi, Eun Yeong ;
Choi, Yong Duck ;
Lee, Won Suk ;
Chung, Jin Teak ;
Kwak, Jae Su .
APPLIED THERMAL ENGINEERING, 2013, 51 (1-2) :435-441
[4]  
Corman J. C., 1996, P INT GAS TURB AER C
[5]   Blade cooling improvement for heavy duty gas turbine: the air coolant temperature reduction and the introduction of steam and mixed steam/air cooling [J].
Facchini, B ;
Ferrara, G ;
Innocenti, L .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2000, 39 (01) :74-84
[6]   DEVELOPING HEAT-TRANSFER IN RECTANGULAR CHANNELS WITH RIB TURBULATORS [J].
HAN, JC ;
PARK, JS .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1988, 31 (01) :183-195
[7]   HEAT-TRANSFER AND FRICTION CHARACTERISTICS IN RECTANGULAR CHANNELS WITH RIB TURBULATORS [J].
HAN, JC .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1988, 110 (02) :321-328
[8]   AUGMENTED HEAT-TRANSFER IN RECTANGULAR CHANNELS OF NARROW ASPECT RATIOS WITH RIB TURBULATORS [J].
HAN, JC ;
OU, S ;
PARK, JS ;
LEI, CK .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1989, 32 (09) :1619-1630
[9]   Critical view on "new results in micro-fluid mechanics": an example [J].
Herwig, H ;
Hausner, O .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (05) :935-937
[10]  
Kline S.J., 1952, ASME Mechanical Engineering, V75, P3, DOI DOI 10.1016/J.CHAOS.2005.11.046